Technological innovations have been a matter of contention, and their environmental consequences remain unresolved. Moreover, studies have extensively evaluated environmental challenges using metrics such as nitrogen oxide emissions, sulfur dioxide, carbon emissions, and ecological footprint. The environment has the supply and demand aspect, which is not a component of any of these indicators. By measuring biocapacity and ecological footprint, the load capacity factor follows a certain ecological threshold, allowing for a thorough study on environmental deterioration. With the reduction in load capacity factor, the environmental deterioration increases. In the context of the environment, the interaction between technological innovation and load capacity covers the demand and supply side of the environment. In light of this, employing the dataset ranging from 1980 to 2017 for the case of South Africa, the bound cointegration test in conjunction with the critical value of Kripfganz and Schneider showed cointegration in the model. The study also employed the ARDL, whose outcome revealed that nonrenewable energy usage and economic growth contribute to environmental deterioration, whereas technological innovation and globalization improve the quality of the environment. This study validated the hypothesis of the environmental Kuznets curve for South Africa, as the short-term coefficient value was lower than the long-term elasticity. Furthermore, using the frequency-domain causality test revealed that globalization and economic growth predict load capacity in the long term, and nonrenewable energy predicts load capacity factors in the long and medium term. In addition, technological innovation predicts load capacity factors in the short and long term. Based on the findings, we propose that policymakers should focus their efforts on increasing funding for the research and development of green technologies.
In this paper, a combined structure of algorithms based on field-oriented control (FOC) and direct torque control (DTC) is proposed for improving the performance of a three-phase induction motor (IM) over a wide range of torque loads. The objective of this study is to investigate the state-of-the-art research performed on the resilient intersection control management between FOC and DTC algorithms for IM drive. Three algorithms are employed in the proposed scheme: Direct Torque Stator Flux Control (DTSFC), Direct Torque Rotor Flux Control (DTRFC), and the FOC algorithm. The main aim of the control law is to launch the drive system by selecting DTSFC or DTRFC during the transient state while FOC is switched smoothly to the steady-state. The proposed method had several advantages, including the ability to produce torque beyond the pull-out torque range at 340%, high torque dynamics during transient state within 0.5 ms, low chattering up to 0.05 N.m, and fixed frequency at steady-state operation. Furthermore, a comprehensive comparison study has been conducted, including the most recent research, to verify the effectiveness and superiority of the proposed technique. Results were obtained using both MATLAB/Simulink environment and also were experimentally performed by using a dSPACE DS1103 digital signal processing board to verify the concept of the proposed control scheme.
This paper proposes a robust and effective method of direct torque and rotor flux control (DTRFC) strategy for an induction motor (IM). The described scheme ensures the elimination of uncontrollable angles (UCAs) over the entire speed range. This means that each voltage vector (VV) produces the required effect of both torque and flux without any counteracting effect. First, the behaviour of the DTRFC algorithm was analysed at low and high speeds in terms of determining the values of UCAs. Through the analysis, it was found that the basic scheme suffered from UCAs at medium and high speeds. Accordingly, a special strategy for medium and high speeds with 18 sub-sectors (SSs) was proposed while maintaining the basic 6 sectors strategy for low speed. The transition speed between the two strategies was determined to ensure the absence of UCAs over the whole speed range. The simulation results of the proposed method were obtained in the MATLAB/Simulink environment. Furthermore, to verify the effectiveness of this method, a dSPACE-based experimental induction motor DTRFC drive system was accomplished.
The electrical power infrastructure of the modern world is advanced, efficient, and robust, yet power outages still occur. In addition to affecting millions of people around the world, these outage events cost billions of dollars to the global economy. In this paper, the revenue loss borne by electricity-supplying companies in the United States due to power outage events is estimated and predicted. Various factors responsible for power outages are considered in order to present an exploratory data analysis at the U.S. level, followed by the top ten affected states, which bear over 85% of the total revenue loss. The loss is computed using historic observational data of electricity usage patterns and the tariff offered by the energy suppliers. The study is supplemented with reliable and publicly available records, including electricity usage patterns, the consumer category distribution, climatological annotations, population density, socio-economic indicators and land area. Machine learning techniques are used to predict the revenue loss for future outage events, as well as to characterize the key parameters for efficient prediction and their partial dependence. The results show that the revenue loss is a function of several parameters, including residential sales, percentage of industrial customer, time-period of the year, and economic indicators. This study may help energy suppliers make risk-informed decisions, while developing revenue generation strategies as well as identifying safer investment avenues for long-term returns.
Direct torque control (DTC) is a promising control algorithm that is characterized by simplicity and effective performance for the AC motors drive systems. The design of the switching table is an important issue that directly affects the performance of the motor drive. The majority of the prior literature relies on the researcher’s knowledge when establishing the voltage vectors of the switching table to be applied to the inverter. Consequently, torque and flux ripples can still be large. In this paper, a modified twelve sector-based DTC is proposed to improve the AC motor drive. The proposed drive system offers several contributions, such as very low torque ripple reduction, faster dynamics, and reduced stator flux ripples compared to the classical DTC. Additionally, the proposed controller can provide high robustness at very low speed under parameter variation. The analytically developed switching table also contributes to reducing the switching frequency ratio between 40% to 50%. The aim of the aforementioned improvements is to obtain a quiet operation of the induction motor without vibration or audible noise. Simulation results of the proposed method were performed in MATLAB/Simulink environment. Furthermore, for the sake of validation and effectiveness of the method, experimental tests were conducted using dSPACE based platform. Finally, a fair comparison of both the proposed and classical methods was performed that revealed the superiority of the proposed strategy.