Nadia Cattari

Dr. Nadia Cattari

University of Pisa, Pisa, Tuscany, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2021 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Sara CondinoSara Condino
Sara Condino
Nicola MontemurroNicola Montemurro
Nicola Montemurro
Nadia CattariNadia Cattari
Nadia Cattari
RDRenzo D’aMato
Renzo D’aMato
UTUlrich Thomale
Ulrich Thomale
Fabrizio CutoloFabrizio Cutolo
Fabrizio Cutolo

24 December 2019 in IEEE Access
Verified
Journal Article
Open access
Fabrizio CutoloFabrizio Cutolo
Fabrizio Cutolo
BFBenish Fida
Benish Fida
Nadia CattariNadia Cattari
Nadia Cattari
Vincenzo FerrariVincenzo Ferrari
Vincenzo Ferrari
The growing availability of self-contained and affordable augmented reality headsets such as the Microsoft HoloLens is encouraging the adoption of these devices also in the healthcare sector. However, technological and human-factor limitations still hinder their routine use in clinical practice. Among them, the major drawbacks are due to their general-purpose nature and to the lack of a standardized framework suited for medical applications and devoid of platform-dependent tracking techniques and/or complex calibration procedures. To overcome such limitations, in this paper we present a software framework that is designed to support the development of augmented reality applications for custom-made headmounted displays designed to aid high-precision manual tasks. The software platform is highly configurable, computationally efficient, and it allows the deployment of augmented reality applications capable to support in situ visualization of medical imaging data. The framework can provide both optical and video seethrough-based augmentations and it features a robust optical tracking algorithm. An experimental study was designed to assess the efficacy of the platform in guiding a simulated task of surgical incision. In the experiments, the user was asked to perform a digital incision task, with and without the aid of the augmented reality headset. The task accuracy was evaluated by measuring the similarity between the traced curve and the planned one. The average error in the augmented reality tests was < 1 mm. The results confirm that the proposed framework coupled with the new-concept headset may boost the integration of augmented reality headsets into routine clinical practice.

Nicola MontemurroNicola Montemurro
Nicola Montemurro
Sara CondinoSara Condino
Sara Condino
MCMarina Carbone
Marina Carbone
Nadia CattariNadia Cattari
Nadia Cattari
RDRenzo D’Amato
Renzo D’Amato
Vincenzo FerrariVincenzo Ferrari
Vincenzo Ferrari
In recent years, huge progress has been made in the management of brain tumors, due to the availability of imaging devices, which provide fundamental anatomical and pathological information not only for diagnostic purposes

Nicola MontemurroNicola Montemurro
Nicola Montemurro
Sara CondinoSara Condino
Sara Condino
Nadia CattariNadia Cattari
Nadia Cattari
RDRenzo D’Amato
Renzo D’Amato
Vincenzo FerrariVincenzo Ferrari
Vincenzo Ferrari
Fabrizio CutoloFabrizio Cutolo
Fabrizio Cutolo
Background: This report discusses the utility of a wearable augmented reality platform in neurosurgery for parasagittal and convexity en plaque meningiomas with bone flap removal and custom-made cranioplasty. Methods: A real patient with en plaque cranial vault meningioma with diffuse and extensive dural involvement, extracranial extension into the calvarium, and homogeneous contrast enhancement on gadolinium-enhanced T1-weighted MRI, was selected for this case study. A patient-specific manikin was designed starting with the segmentation of the patient’s preoperative MRI images to simulate a craniotomy procedure. Surgical planning was performed according to the segmented anatomy, and customized bone flaps were designed accordingly. During the surgical simulation stage, the VOSTARS head-mounted display was used to accurately display the planned craniotomy trajectory over the manikin skull. The precision of the craniotomy was assessed based on the evaluation of previously prepared custom-made bone flaps. Results: A bone flap with a radius 0.5 mm smaller than the radius of an ideal craniotomy fitted perfectly over the performed craniotomy, demonstrating an error of less than ±1 mm in the task execution. The results of this laboratory-based experiment suggest that the proposed augmented reality platform helps in simulating convexity en plaque meningioma resection and custom-made cranioplasty, as carefully planned in the preoperative phase. Conclusions: Augmented reality head-mounted displays have the potential to be a useful adjunct in tumor surgical resection, cranial vault lesion craniotomy and also skull base surgery, but more study with large series is needed.

14 January 2025 in Frontiers in Digital Health
Verified
Journal Article
Open access
PDF file
MCMarina Carbone
Marina Carbone
NMNicola Montemurro
Nicola Montemurro
Nadia CattariNadia Cattari
Nadia Cattari
MAMartina Autelitano
Martina Autelitano
FCFabrizio Cutolo
Fabrizio Cutolo
SCSara Condino
Sara Condino
Wearable augmented reality in neurosurgery offers significant advantages by enabling the visualization of navigation information directly on the patient, seamlessly integrating virtual data with the real surgical field. This ergonomic approach can facilitate a more intuitive understanding of spatial relationships and guidance cues, potentially reducing cognitive load and enhancing the accuracy of surgical gestures by aligning critical information with the actual anatomy in real-time. This study evaluates the benefits of a novel AR platform, VOSTARS, by comparing its targeting accuracy to that of the gold-standard electromagnetic (EM) navigation system, Medtronic StealthStation® S7®. Both systems were evaluated in phantom and human studies. In the phantom study, participants targeted 13 predefined landmarks using identical pointers to isolate system performance. In the human study, three facial landmarks were targeted in nine volunteers post-brain tumor surgery. The performance of the VOSTARS system was superior to that of the standard neuronavigator in both the phantom and human studies. In the phantom study, users achieved a median accuracy of 1.4 mm (IQR: 1.2 mm) with VOSTARS compared to 2.9 mm (IQR: 1.4 mm) with the standard neuronavigator. In the human study, the median targeting accuracy with VOSTARS was significantly better for selected landmarks in the outer eyebrow (3.7 mm vs. 6.6 mm, p = 0.05) and forehead (4.5 mm vs. 6.3 mm, p = 0.021). Although the difference for the pronasal point was not statistically significant (2.7 mm vs. 3.5 mm, p = 0.123), the trend towards improved accuracy with VOSTARS is clear. These findings suggest that the proposed AR technology has the potential to significantly improve surgical outcomes in neurosurgery.

25 September 2021 in Bioengineering
Verified
Journal Article
Open access
PDF file
Nadia CattariNadia Cattari
Nadia Cattari
Sara CondinoSara Condino
Sara Condino
Fabrizio CutoloFabrizio Cutolo
Fabrizio Cutolo
MFMauro Ferrari
Mauro Ferrari
Vincenzo FerrariVincenzo Ferrari
Vincenzo Ferrari
Augmented Reality (AR) headsets have become the most ergonomic and efficient visualization devices to support complex manual tasks performed under direct vision. Their ability to provide hands-free interaction with the augmented scene makes them perfect for manual procedures such as surgery. This study demonstrates the reliability of an AR head-mounted display (HMD), conceived for surgical guidance, in navigating in-depth high-precision manual tasks guided by a 3D ultrasound imaging system. The integration between the AR visualization system and the ultrasound imaging system provides the surgeon with real-time intra-operative information on unexposed soft tissues that are spatially registered with the surrounding anatomic structures. The efficacy of the AR guiding system was quantitatively assessed with an in vitro study simulating a biopsy intervention aimed at determining the level of accuracy achievable. In the experiments, 10 subjects were asked to perform the biopsy on four spherical lesions of decreasing sizes (10, 7, 5, and 3 mm). The experimental results showed that 80% of the subjects were able to successfully perform the biopsy on the 5 mm lesion, with a 2.5 mm system accuracy. The results confirmed that the proposed integrated system can be used for navigation during in-depth high-precision manual tasks.