(1) Background and Objectives: Mitral regurgitation is a common valve disease requiring surgical repair. Even with satisfactory results, repair techniques may underlie subjectivity and variability and require long learning curves. A novel approach, the “Roman Arch” technique, may ease the technical burden. This study assessed an automated suturing device’s feasibility and time efficiency for a proposed simplified technique. (2) Materials and Methods: Using the MiStitch™ and MiKnot™ devices (LSI Solutions, Inc., Victor, NY, USA), the suture pattern was performed in a cadaver model. Three surgeons with different expertise levels conducted the procedures. Repair and suture placement times were recorded and analyzed. (3) Results: The modified “Roman Arch” repair was completed on all ten human heart specimens with an average total repair time of 3:01 ± 00:59 min and a trend toward reduced times as experience increased. The study confirmed the technical feasibility with 90% of the attempts rated as rather satisfactory or very satisfactory. (4) Conclusions: The MiStitch™ system effectively facilitated the modified “Roman Arch” repair in an ex vivo setting, suggesting its potential to reduce the technical complexity of mitral valve repairs. Further studies are needed to confirm its efficacy and safety in clinical practice.
Coronary artery bypass grafting is frequently performed in combination with valve surgery; however, minimally invasive approaches for such combined procedures remain limited due to challenges in exposure and access. While bilateral minimally invasive strategies have been described in selected cases, standardized access concepts for concomitant procedures are not well defined. This study aimed to assess the anatomical accessibility and procedural workflow of a minimally invasive biaxillary access strategy for combined coronary and valve surgery in a human cadaver model. Combined coronary artery bypass grafting and valve procedures were performed in nine Thiel/ethanol-fixed human cadavers using a biaxillary access approach. Anatomical exposure, conduit length, graft harvesting and anastomosis times, and valve positioning were evaluated by macroscopic inspection and postprocedural three-dimensional computed tomography imaging. All planned procedural steps were completed in all nine cadavers. The mean left and right internal thoracic artery lengths were 18.1 ± 1.8 cm and 18.9 ± 1.9 cm, respectively. The average bilateral internal thoracic artery harvest and anastomosis times were 52.0 ± 17.6 min and 46.6 ± 12.6 min, respectively. Postprocedural three-dimensional computed tomography imaging and macroscopic inspection demonstrated consistent graft positioning and anatomical valve seating across all specimens. This cadaveric study demonstrates that a minimally invasive biaxillary access strategy allows anatomical exposure and supports a conceptual procedural workflow for combined coronary and valve interventions. These findings represent an early-stage technical proof-of-concept and require further validation before clinical application can be considered.
Tricuspid regurgitation (TR) is a prevalent finding in echocardiography and in case of severe disease is associated with impaired patient outcome. Clover repair offers a surgical solution that can be applied for the treatment of primary and secondary TR. An ex vivo passive beating porcine heart model was created to test a modified clover technique using automated suturing devices and to compare this approach to standard ring annuloplasty. Secondary TR was induced in 10 porcine hearts and the backflow of fluid was assessed. The primary endpoint of this study was regurgitant volume measured in mL at the site right atrial cannula. The baseline regurgitation was 43.3 ± 10.8 mL. The mean regurgitant volume was significantly reduced after all repair procedures to 22.2 ± 5.9 mL with isolated ring annuloplasty, 12 ± 3.9 mL with the modified clover, and 7.6 ± 3.4 mL with the combined procedure (p < 0.0001). The modified clover technique shows how to effectively reduce TR in an ex vivo model. This method may be suitable to facilitate tricuspid repair, especially for totally endoscopic valve surgery.
17 June 2026 in Frontiers in Bioengineering and Biotechnology
Background: Glutaraldehyde (GA) fixation of pericardial tissue is widely used in bioprosthetic heart valves. However, how GA concentration and incubation time jointly influence structure-function relationships remains incompletely understood. This study systematically evaluates the effects of GA concentration and incubation time on collagen architecture and mechanical behavior in human pericardial tissue. Results: Human pericardium was treated with GA concentrations of 0%–2.5% for 5–90 min. Collagen structure was quantified using Picrosirius red imaging and image analysis, while mechanical behavior was assessed via strain-controlled uniaxial tensile testing. Increasing incubation time was associated with reduced collagen waviness and evidence of fiber bundling. Mechanical analysis revealed a significant interaction between GA concentration and incubation time for maximum strain and transition strain (p < 0.05), indicating a non-linear, non-additive treatment effect. Repeated-measures correlation analysis showed strong internal consistency among mechanical parameters (e.g., maximum stress vs. high-strain modulus, r rm = 0.92), whereas structural descriptors such as waviness and fiber orientation exhibited minimal association with mechanical outcomes (r rm = 0.06). Conclusion: GA treatment effects arise from a coupled, non-additive interaction between concentration and incubation time rather than a simple dose-response relationship. Importantly, commonly used structural metrics do not directly predict mechanical performance, underscoring the need for integrated structure-function assessment. These findings provide a framework for future evaluation of GA-treated pericardium in bioprosthetic applications.