Shared ventilation is an interesting topic amongst researchers due to the possibility of healthcare saturation under disaster conditions provoked by viruses, war environments, diffusive respiratory system diseases, etc. However, general outcomes from this practice have shown several risks. The Multiple Emergency Ventilator overcomes these hazards by providing a temporary, pressure-controlled ventilatory support for up to ten patients simultaneously, whilst allowing for a modular and fast assembly during emergencies. This article presents the construction and the assessment of the prototype using patient simulators with different types of bio-mechanical characteristic configurations at ten hospitalization stations. Ventilation parameters at the most distal-to-source station were recorded. Under normal operation, a minute ventilation of 9.6 breaths × L × min −1 was obtained. Critical operation during different types of localized sudden pneumatic disconnections was also investigated. Amongst these, only the event of a disconnection of any simulator at its pneumatic connection to the main distribution pipeline highlighted a poor minute ventilation of 4 breaths × L × min −1 . Yet, the probability of such an event is minimal due to the use of safe mechanical constraints at the relevant pneumatic connections. In this first prototype assessment, the device has shown its capabilities to ventilate multiple patients with consistent pressure behaviours even whilst adverse conditions are imposed. Graphical Abstract

15 July 2024 in Medicina
Verified
Journal Article
Open access
PDF file
Thomas PoschnerThomas Poschner
Thomas Poschner
SLSeverin Laengle
Severin Laengle
Sahra Tasdelen, BSc MScSahra Tasdelen, BSc MSc
Sahra Tasdelen, BSc MSc
Aldo Jose Suria RoldanAldo Jose Suria Roldan
Aldo Jose Suria Roldan
FBFunda Baysal
Funda Baysal
MAMartin Andreas
Martin Andreas
(1) Background and Objectives: Mitral regurgitation is a common valve disease requiring surgical repair. Even with satisfactory results, repair techniques may underlie subjectivity and variability and require long learning curves. A novel approach, the “Roman Arch” technique, may ease the technical burden. This study assessed an automated suturing device’s feasibility and time efficiency for a proposed simplified technique. (2) Materials and Methods: Using the MiStitch™ and MiKnot™ devices (LSI Solutions, Inc., Victor, NY, USA), the suture pattern was performed in a cadaver model. Three surgeons with different expertise levels conducted the procedures. Repair and suture placement times were recorded and analyzed. (3) Results: The modified “Roman Arch” repair was completed on all ten human heart specimens with an average total repair time of 3:01 ± 00:59 min and a trend toward reduced times as experience increased. The study confirmed the technical feasibility with 90% of the attempts rated as rather satisfactory or very satisfactory. (4) Conclusions: The MiStitch™ system effectively facilitated the modified “Roman Arch” repair in an ex vivo setting, suggesting its potential to reduce the technical complexity of mitral valve repairs. Further studies are needed to confirm its efficacy and safety in clinical practice.

13 November 2026 in Artificial Organs
Verified
Journal Article
Open access
Aldo Jose Suria RoldanAldo Jose Suria Roldan
Aldo Jose Suria Roldan
NCNiccolò Crescenti
Niccolò Crescenti
BTBenjamin Torner
Benjamin Torner
DZDaniel Zimpfer
Daniel Zimpfer
Marcus GraneggerMarcus Granegger
Marcus Granegger
Objective: Variability of 3D‐printed rotodynamic blood pumps (RBP) indicators is a crucial factor in haemocompatibility evaluation. Thus, the aim is to investigate the reproducibility of a 3D printed‐based framework for further use on systematic haemocompatible studies when changing key impeller parameters in RBPs. Methods: Reproducibility was assessed in terms of standard deviation (SD), of the normalized index of haemolysis (NIH) and generated pressure head between 3 RBPs. A conventionally manufactured benchmark RBP, one 3D printed (3DP) exact replica, (), and one 3DP with a modification () ( n = 7). In vitro haemolysis experiments were carried out. Newly 3DP impellers were used for each experiment to study the manufacturing reproducibility. Moreover, pressure head‐flow rate curve analysis and computational fluid dynamic (CFD) simulations were performed to support the findings. Results: The mean NIH ± SD in mg/100 L for the 3 RBPs was 4.25 ± 1.95 for the benchmark, 6.40 ± 2.68 for the exact replica, and 7.75 ± 1.87 for the modified version. Only a significant difference ( p < 0.05) between the benchmark and modified version was found. Conversely, no strong statistical differences were found between the 3DP RBPs. Furthermore, SD values of pressure heads were similar between all the groups. The resulting damage index for the 3DP geometries was 2.37 (·10 −4 ) and 2.32 (·10 −4 ) for the replica and modified version respectively. Suggesting a probable small effect when variating in free stream pumps. Conclusions: Same NIH and pressure head SD range has shown the viability of the 3DP experimental framework, proposing an economic and rapid path for systematic haemocompatibility studies of parameters in RBPs.

29 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
SLSeverin Laengle
Severin Laengle
Aldo Jose Suria RoldanAldo Jose Suria Roldan
Aldo Jose Suria Roldan
Thomas PoschnerThomas Poschner
Thomas Poschner
Sahra Tasdelen, BSc MScSahra Tasdelen, BSc MSc
Sahra Tasdelen, BSc MSc
APAntonios Pitsis
Antonios Pitsis
MAMartin Andreas
Martin Andreas
Tricuspid regurgitation (TR) is a prevalent finding in echocardiography and in case of severe disease is associated with impaired patient outcome. Clover repair offers a surgical solution that can be applied for the treatment of primary and secondary TR. An ex vivo passive beating porcine heart model was created to test a modified clover technique using automated suturing devices and to compare this approach to standard ring annuloplasty. Secondary TR was induced in 10 porcine hearts and the backflow of fluid was assessed. The primary endpoint of this study was regurgitant volume measured in mL at the site right atrial cannula. The baseline regurgitation was 43.3 ± 10.8 mL. The mean regurgitant volume was significantly reduced after all repair procedures to 22.2 ± 5.9 mL with isolated ring annuloplasty, 12 ± 3.9 mL with the modified clover, and 7.6 ± 3.4 mL with the combined procedure (p < 0.0001). The modified clover technique shows how to effectively reduce TR in an ex vivo model. This method may be suitable to facilitate tricuspid repair, especially for totally endoscopic valve surgery.