Severin Laengle

Dr. Severin Laengle


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AKAmila Kahrovic
Amila Kahrovic
PAPhilipp Angleitner
Philipp Angleitner
HHHarald Herkner
Harald Herkner
PWPaul Werner
Paul Werner
AAAlexandra Andreeva
Alexandra Andreeva
MAMartin Andreas
Martin Andreas
Objectives: This study aimed to compare the clinical outcomes of mechanical and biological valve prostheses in patients with infective endocarditis presenting with stroke. Methods: Ninety-five adults with infective endocarditis complicated by stroke at baseline who underwent aortic and/or mitral valve replacement were analyzed retrospectively. The primary outcome was a composite outcome of all-cause mortality, ischemic stroke, hemorrhagic stroke, and re-endocarditis. Secondary outcomes included the individual components of the composite outcome and modified Rankin scale deterioration during follow-up. Results: Among the study cohort, 34 patients (35.8%) received mechanical valve prostheses and 61 (64.2%) received biological valve prostheses. Implantation of a mechanical valve prosthesis seems to be associated with a decreased risk of attaining the composite outcome (adjusted HR 0.46, 95% CI 0.22–0.96, and p = 0.037). Analyses of the individual components of the composite outcome showed that implantation of a mechanical valve prosthesis might not be associated with an increased risk of ischemic stroke, hemorrhagic stroke, and all-cause mortality during the follow-up period. Further, the risk of re-endocarditis was significantly lower in recipients of a mechanical valve prosthesis (adjusted HR 0.15, 95% CI 0.06–0.77, p = 0.026). Notably, a trend toward decreased risk of modified Rankin scale deterioration throughout the follow-up period was observed in this group (adjusted odds ratio 0.22, 95% CI 0.05–1.02, p = 0.053). Conclusions: Implantation of mechanical valve prostheses in patients presenting with infective endocarditis complicated by stroke seems to be beneficial in terms of a reduced risk of experiencing a composite outcome. Analyses of larger cohorts are required to validate our findings.

15 July 2024 in Medicina
Verified
Journal Article
Open access
PDF file
Thomas PoschnerThomas Poschner
Thomas Poschner
SLSeverin Laengle
Severin Laengle
Sahra Tasdelen, BSc MScSahra Tasdelen, BSc MSc
Sahra Tasdelen, BSc MSc
Aldo Jose Suria RoldanAldo Jose Suria Roldan
Aldo Jose Suria Roldan
FBFunda Baysal
Funda Baysal
MAMartin Andreas
Martin Andreas
(1) Background and Objectives: Mitral regurgitation is a common valve disease requiring surgical repair. Even with satisfactory results, repair techniques may underlie subjectivity and variability and require long learning curves. A novel approach, the “Roman Arch” technique, may ease the technical burden. This study assessed an automated suturing device’s feasibility and time efficiency for a proposed simplified technique. (2) Materials and Methods: Using the MiStitch™ and MiKnot™ devices (LSI Solutions, Inc., Victor, NY, USA), the suture pattern was performed in a cadaver model. Three surgeons with different expertise levels conducted the procedures. Repair and suture placement times were recorded and analyzed. (3) Results: The modified “Roman Arch” repair was completed on all ten human heart specimens with an average total repair time of 3:01 ± 00:59 min and a trend toward reduced times as experience increased. The study confirmed the technical feasibility with 90% of the attempts rated as rather satisfactory or very satisfactory. (4) Conclusions: The MiStitch™ system effectively facilitated the modified “Roman Arch” repair in an ex vivo setting, suggesting its potential to reduce the technical complexity of mitral valve repairs. Further studies are needed to confirm its efficacy and safety in clinical practice.

29 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
SLSeverin Laengle
Severin Laengle
Aldo Jose Suria RoldanAldo Jose Suria Roldan
Aldo Jose Suria Roldan
Thomas PoschnerThomas Poschner
Thomas Poschner
Sahra Tasdelen, BSc MScSahra Tasdelen, BSc MSc
Sahra Tasdelen, BSc MSc
APAntonios Pitsis
Antonios Pitsis
MAMartin Andreas
Martin Andreas
Tricuspid regurgitation (TR) is a prevalent finding in echocardiography and in case of severe disease is associated with impaired patient outcome. Clover repair offers a surgical solution that can be applied for the treatment of primary and secondary TR. An ex vivo passive beating porcine heart model was created to test a modified clover technique using automated suturing devices and to compare this approach to standard ring annuloplasty. Secondary TR was induced in 10 porcine hearts and the backflow of fluid was assessed. The primary endpoint of this study was regurgitant volume measured in mL at the site right atrial cannula. The baseline regurgitation was 43.3 ± 10.8 mL. The mean regurgitant volume was significantly reduced after all repair procedures to 22.2 ± 5.9 mL with isolated ring annuloplasty, 12 ± 3.9 mL with the modified clover, and 7.6 ± 3.4 mL with the combined procedure (p < 0.0001). The modified clover technique shows how to effectively reduce TR in an ex vivo model. This method may be suitable to facilitate tricuspid repair, especially for totally endoscopic valve surgery.

18 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RHRomy Maria Jacqueline Josepha Hegeman
Romy Maria Jacqueline Josepha Hegeman
SPSimon Eduard van Putten
Simon Eduard van Putten
LTLeo Timmers
Leo Timmers
BRBenno J. W. M. Rensing
Benno J. W. M. Rensing
USUday Sonker
Uday Sonker
PKPatrick Klein
Patrick Klein
Background/Objectives: Paravalvular leak and permanent pacemaker implantation remain relevant issues after transcatheter aortic valve implantation (TAVI). Novel device development as well as adequate preprocedural device selection can contribute to optimal outcomes. Methods: Computed tomography-based patient-specific computer anatomical analysis and simulation were used in addition to standard preprocedural preparation in three of the first Evolut FX cases in our center. Procedural and follow-up echocardiographic outcomes are presented. Results: Computed tomography-based computer simulation of Evolut FX resulted in implantation of a different size in one of three cases. In three cases of severe aortic valve stenosis, procedural as well as follow-up outcomes were satisfactory and in line with the simulated results of the chosen strategy. Conclusions: Preprocedural patient-specific computer simulation predicts and guides decision-making in TAVI with the Evolut FX platform. The combination of advanced preprocedural technology and novel technologies continues to contribute to the optimization of TAVI outcomes.