The quality of the indoor environment has become a vital component for buildings due to the time spent indoors. To this extent, the performance of the indoor environment is considered as part of the greenery criteria by green rating schemes such as the Green Building Index in Malaysia. This study aims to investigate and assess the quality of the indoor environment of Platinum-certified office buildings in a tropical climate. This research applied a case study approach over two Platinum-certified office buildings. Post-occupancy evaluation is employed integrating full-scale measurement with an occupants’ survey. The measurement was carried out from May to August, and 112 questionnaires were retrieved to evaluate occupants’ satisfaction with aspects of the indoor environment. Thermal comfort, indoor air quality, acoustic, lighting, furniture, and cleanliness are considered as the main study variables. The findings of full-scale measurement indicated high relative humidity, and low air velocity and illuminance. While occupants reported overall indoor environment quality (IEQ) comfort, a significant correlation of variables was observed. The main sources of dissatisfaction were identified as overcooling around 24 °C, high relative humidity (RH), around 70% RH, glare, and background noise around 51.9 dB. Statistically, a significant difference between occupants’ responses to IEQ of two cases was identified, although both buildings are labelled with a Platinum certificate.
Global warming has become an increasing challenge due to the impact of human activities on the environment. In this regard, university campuses with various activities and departments have a great impact on the environment. Ecological Footprint Analysis (EFA) is a natural resource depletion assessment tool, with a high level of accuracy, that measures the impact of human activities on the environment. Considering the Ecological Footprint (EF) capabilities, this study developed a method to assess the environmental impacts of a university campus using component-based parameters. The goals of the study are to explore the effective components of EF and to propose some policy guidelines to diminish the human impacts on the environment on university campuses. Five components, including natural gas and electricity consumption, water and food usage, and waste production, were measured in a survey from 2013 to 2016 at the building scale. The mean EF of the campus was 16,484 global hectares (gha). Fossil fuel energy had the highest level of environmental impact with 70.73%, followed by waste production and food and water usage with 26.87%, 1.28%, and 1.12%, respectively. The results demonstrate that the EF Index (EFI) of the case study campus was −0.82, which reveals an unsustainable performance. The EF results were illustrated on an Ecological Footprint Map (EFM), which shows the east and west parts of the camps were more unsustainable.
In 2008, the Chartered Institution of Building Services Engineers (CIBSE TM46 UC) presented an annual-fixed thermal energy benchmark of 240 kWh/m2/yr for university campus (UC) buildings as an attempt to reduce energy consumption in public buildings. However, the CIBSE TM46 UC benchmark fails to consider the difference between energy demand in warm and cold months, as the thermal performance of buildings largely depends on the ambient temperature. This paper presents a new generation of monthly thermal energy benchmarks (MTEBs) using two computational methods including mixed-use model and converter model, which consider the variations of thermal demand throughout a year. MTEBs were generated using five basic variables, including mixed activities in the typical college buildings, university campus revised benchmark (UCrb), typical operation of heating systems, activities impact, and heating degree days. The results showed that MTEBs vary from 24 kWh/m2/yr in January to one and nearly zero kWh/m2/yr in June and July, respectively. Based on the detailed assessments, a typical college building was defined in terms of the percentage of its component activities. Compared with the 100% estimation error of the TM46 UC benchmark, the maximum 21% error of the developed methodologies is a significant achievement. The R-squared value of 99% confirms the reliability of the new generation of benchmarks.
Visual comfort affects the quality of classrooms as well as student learning. A practice-oriented approach discovers how the gap between academic research and its application in building design can be addressed. Nevertheless, the physical characteristics design of daylighting systems, including window sizes, shapes, dimensions, and materials, are considered fundamental challenges for their practicability. In this study, the physical characteristics design of daylighting systems, including window sizes, shapes, dimensions, and materials, are considered in a designed sample school, and the daylight metrics were analyzed to achieve more trustworthy and applicable daylighting systems. Grasshopper (Honeybee-Ladybug), as a parametric control method, was applied to simulate the daylighting quality for various educational spaces in a secondary school in Sanandaj City, based on average ‘Daylight Factor’, ‘Daylight Autonomy’, ‘Useful Daylight Illuminance’, and ‘Annual Sunlight Exposure’. These metrics were examined to discover the relationship between window size and positions on visual comfort. The results indicate daylighting assessments are a solid approach to revising the architectural design mistakes at the primary designing phase. Architects and other building designers or energy consumption assessors can apply the design improvement process to present more sufficient and successful architectural details. This is a fundamental step toward the implementation of green buildings.