Sang-Hun Kim

Mr. Sang-Hun Kim

Power Electronics Lab (PEL) in Ajou University
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2020 in IEEE Access
Verified
Journal Article
Open access
SKSang-Hun Kim
Sang-Hun Kim
DYDong-Yeon Yoo
Dong-Yeon Yoo
SASang-Won An
Sang-Won An
YPYe-Seul Park
Ye-Seul Park
JLJung-Won Lee
Jung-Won Lee
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
This paper presents an open-switch fault detection method for a hybrid active neutral-point clamped (HANPC) inverter based on deep learning technology. The HANPC inverter generates a three-level output voltage with four silicon switches and two silicon carbide switches per phase. The probability of open fault in switching devices increases because of the large number of switches of the entire power converter. The open-switch fault causes distortion of output currents. A convolution neural network (CNN) comprising several convolution layers and fully connected layers is used to extract features of distorted currents. A CNN network was trained using three-phase current information to determine the location of the open-switch fault. Our proposed CNN model can accurately detect approximately 99.6% of open-switch faults without requiring additional circuitry and regardless of the current level. The feasibility and effectiveness of the proposed method are verified by experimental results.

15 February 2003 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
JCJu H. Choi
Ju H. Choi
HSHee-Seung Shin
Hee-Seung Shin
SKSang-Hun Kim
Sang-Hun Kim
JMJong-Ha Moon
Jong-Ha Moon
BLByung-Teak Lee
Byung-Teak Lee

28 February 2020 in Electronics
Verified
Journal Article
Open access
PDF file
BKBong Hyun Kwon
Bong Hyun Kwon
SKSang-Hun Kim
Sang-Hun Kim
SKSeok-Min Kim
Seok-Min Kim
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
A diagnostic method for an open-circuit switch failure in a hybrid active neutral-point clamped (HANPC) inverter is proposed in this paper. The switching leg of the HANPC inverter consists of four silicon insulated gate bipolar transistors and two silicon carbide metal-oxide-semiconductor field-effect transistors to achieve higher efficiency and power density compared to conventional neutral-point clamped inverters. When an open-circuit failure occurs in a switching device, the output current is severely distorted, causing damage to the inverter and the connected loads. The proposed diagnostic method aims to detect the open-switch failure and protect the related devices without additional sensors or circuits. The faulty conditions of six different switches are investigated based on the current distortion in the stationary reference frame. By analyzing the individual characteristic of each switch failure, it is possible to detect the exact location of the failed switch in a short period. The effectiveness and feasibility of the proposed fault-diagnostic method are verified using simulation and experimental results.

3 September 2020 in Electronics
Verified
Journal Article
Open access
PDF file
SKSang-Hun Kim
Sang-Hun Kim
SKSeok-Min Kim
Seok-Min Kim
SPSungmin Park
Sungmin Park
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
This paper proposes a fault-detection method for open-switch failures in hybrid active neutral-point-clamped (HANPC) rectifiers. The basic HANPC topology comprises two SiC-based metal-oxide-semiconductor field-effect transistors (MOSFETs) and four Si insulated-gate bipolar transistors (IGBTs). A three-phase rectifier system using the HANPC topology can produce higher efficiency and lower current harmonics. An open-switch fault in a HANPC rectifier can be a MOSFET or IGBT fault. In this work, faulty cases of six different switches are analyzed based on the current distortion in the stationary reference frame. Open faults in MOSFET switches cause immediate and remarkable current distortions, whereas, open faults in IGBT switches are difficult to detect using conventional methods. To detect an IGBT fault, the proposed detection method utilizes some of the reactive power in a certain period to make an important difference, using the direct-quadrant (dq)-axis current information derived from the three-phase current. Thus, the proposed detection method is based on three-phase current measurements and does not use additional hardware. By analyzing the individual characteristics of each switch failure, the failed switch can be located exactly. The effectiveness and feasibility of the proposed fault-detection method are verified through PSIM simulations and experimental results.

3 August 2020 in IEEE Access
Verified
Journal Article
Open access
YKYe-Ji Kim
Ye-Ji Kim
SKSang-Hun Kim
Sang-Hun Kim
SKSeok-Min Kim
Seok-Min Kim
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
This paper proposes open fault diagnosis and tolerance control methods for grid-connected hybrid active neutral-point-clamped (ANPC) inverters with optimized carrier-based pulse width modulation. The hybrid ANPC inverter is composed of silicon carbide metal-oxide-semiconductor field effect transistors and Si-insulated gate bipolar transistors. Open faults of switch devices lead to the distortion of output currents, inverter performance degradation, and low reliability. Therefore, the open-circuit fault diagnosis and the tolerance control methods should be handled to improve the reliability of the inverter. The fault tolerance control methods for grid-connected inverters should also consider the fixed voltage modulation index as the modulation index is fixed. In this study, the proposed fault tolerance control method handles the open fault without reducing the modulation index. The implementation of the proposed method is easy and can be conducted through a simple change in the reference waveform. The effectiveness of the proposed fault detection and fault tolerance control methods was verified through the simulation and experimental results.

28 March 2022 in IEEE Access
Verified
Journal Article
Open access
JPJin-Ho Park
Jin-Ho Park
WJWoong Jo
Woong Jo
EJEun-Tak Jeon
Eun-Tak Jeon
SKSang-Hun Kim
Sang-Hun Kim
CLChang-Hee Lee
Chang-Hee Lee
CWChung-Yuen Won
Chung-Yuen Won
Most railroad cars employ a natural ventilation cooling method. For this reason, severe problems occur in the control devices for the railroad cars due to the heat generated by the high-power switching loss. Therefore, the traction inverter for the railroad car requires a control method that can reduce the switching loss. In this paper, we propose a control method for an interior permanent magnet synchronous motor in consideration of the driving conditions of the railroad cars. The proposed method combines a variable switching frequency-based synchronous pulse width modulation control method, a flux-weakening control method that considers the maximum voltage modulation index, and an optimized over-modulation method. Through the proposed method, the utilization rate of the DC-link voltage can be maximized while lowering the switching frequency of the traction inverter as much as possible, and the high-performance current control can be performed in the entire speed region of the railroad car. The validity and effectiveness of the proposed method are verified by the simulation results and the experimental results.