Syed Ghufran Khalid

Dr. Syed Ghufran Khalid


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
Syed Ghufran KhalidSyed Ghufran Khalid
Syed Ghufran Khalid
JZJufen Zhang
Jufen Zhang
FCFei Chen
Fei Chen
DZDingchang Zheng
Dingchang Zheng
Introduction. Blood pressure (BP) has been a potential risk factor for cardiovascular diseases. BP measurement is one of the most useful parameters for early diagnosis, prevention, and treatment of cardiovascular diseases. At present, BP measurement mainly relies on cuff-based techniques that cause inconvenience and discomfort to users. Although some of the present prototype cuffless BP measurement techniques are able to reach overall acceptable accuracies, they require an electrocardiogram (ECG) and a photoplethysmograph (PPG) that make them unsuitable for true wearable applications. Therefore, developing a single PPG-based cuffless BP estimation algorithm with enough accuracy would be clinically and practically useful. Methods. The University of Queensland vital sign dataset (online database) was accessed to extract raw PPG signals and its corresponding reference BPs (systolic BP and diastolic BP). The online database consisted of PPG waveforms of 32 cases from whom 8133 (good quality) signal segments (5 s for each) were extracted, preprocessed, and normalised in both width and amplitude. Three most significant pulse features (pulse area, pulse rising time, and width 25%) with their corresponding reference BPs were used to train and test three machine learning algorithms (regression tree, multiple linear regression (MLR), and support vector machine (SVM)). A 10-fold cross-validation was applied to obtain overall BP estimation accuracy, separately for the three machine learning algorithms. Their estimation accuracies were further analysed separately for three clinical BP categories (normotensive, hypertensive, and hypotensive). Finally, they were compared with the ISO standard for noninvasive BP device validation (average difference no greater than 5 mmHg and SD no greater than 8 mmHg). Results. In terms of overall estimation accuracy, the regression tree achieved the best overall accuracy for SBP (mean and SD of difference: −0.1 ± 6.5 mmHg) and DBP (mean and SD of difference: −0.6 ± 5.2 mmHg). MLR and SVM achieved the overall mean difference less than 5 mmHg for both SBP and DBP, but their SD of difference was >8 mmHg. Regarding the estimation accuracy in each BP categories, only the regression tree achieved acceptable ISO standard for SBP (−1.1 ± 5.7 mmHg) and DBP (−0.03 ± 5.6 mmHg) in the normotensive category. MLR and SVM did not achieve acceptable accuracies in any BP categories. Conclusion. This study developed and compared three machine learning algorithms to estimate BPs using PPG only and revealed that the regression tree algorithm was the best approach with overall acceptable accuracy to ISO standard for BP device validation. Furthermore, this study demonstrated that the regression tree algorithm achieved acceptable measurement accuracy only in the normotensive category, suggesting that future algorithm development for BP estimation should be more specific for different BP categories.

19 March 2020 in IEEE Access
Verified
Journal Article
Open access
Syed Ghufran KhalidSyed Ghufran Khalid
Syed Ghufran Khalid
Haipeng LiuHaipeng Liu
Haipeng Liu
TZTahir Zia
Tahir Zia
JZJufen Zhang
Jufen Zhang
FCFei Chen
Fei Chen
DZDingchang Zheng
Dingchang Zheng
Traditional cuff-based blood pressure (BP) monitoring procedure causes inconvenience and discomfort to the users. To overcome these limitations, cuffless BP estimation based on pulse transit time (PTT) and single-channel photoplethysmography (PPG) has been proposed. However, existing studies based on PTT and PPG for BP estimation did not achieve AAMI/ISO standard criteria for BP measurement (mean difference within ±5mmHg and SD of difference within ±8mmHg) under each BP category (Hypotensive, Normotensive and Hypertensive). This study aims to validate an innovative two-step method for PPG-based cuffless BP estimation. A combined database was derived from two online databases (Queensland and MIMIC II) to cover a wide range of corresponding BPs. In total, there were 18010 raw PPG signal segments (5 seconds for each) with corresponding BPs, separated into two halves for training and testing of algorithms (independent datasets). Each PPG signal segment was pre-processed to extract 16 signal features. Later, three significant features have been selected using multicollinearity test. The traditional generic (trained with uncategorized BP) algorithm and two-step algorithm (specifically optimized for each BP category) were developed using machine learning. Generally, the two-step algorithm achieved the AAMI/ISO standard in estimating systolic BP (mean±SD: 0.07±7.1 mmHg, p<0.001) and diastolic BP (-0.08±6.0 mmHg, p<0.001). Categorically, the two-step method also achieved standard accuracy in all BP categories except Hypotensive systolic BP whereas generic algorithm did not conform to standard accuracy in any BP category except Hypotensive diastolic BP and Normotensive categories. Compared to the traditional generic algorithm, the two-step algorithm specifically designed for three different BP category patients and achieved standard accuracy for cuffless BP estimation.

16 October 2024 in IEEE Access
Verified
Journal Article
Open access
AHAhmad Houkan
Ahmad Houkan
ASAshwin Kumar Sahoo
Ashwin Kumar Sahoo
SGSarada Prasad Gochhayat
Sarada Prasad Gochhayat
UPUpasana Kumar Panigrahi
Upasana Kumar Panigrahi
Haipeng LiuHaipeng Liu
Haipeng Liu
Prince JainPrince Jain
Prince Jain
The increasing deployment of Internet of Things devices has introduced significant cyber security challenges, creating a need for robust intrusion detection systems. This research focuses on improving anomaly detection in industrial Internet of Things networks through feature reduction and selection. Experiments were performed to compare the effectiveness of Minimum Redundancy Maximum Relevance for feature selection with Principal Component Analysis for feature reduction. Six machine learning algorithms—Decision Trees, k-nearest neighbors, Gaussian Support Vector Machine, Neural Network, Support Vector Machines kernel, and Logistic Regression Kernel—were evaluated for both binary and multi-class classification using feature sets of 4, 12, 23, 50, and 79 features. The results reveal that Minimum Redundancy Maximum Relevance is superior to Principal Component Analysis in identifying crucial features. Notably, Minimum Redundancy Maximum Relevance achieves high accuracy with just 12 features, where the Decision Tree classifier reached an outstanding 99.9% accuracy in binary classification, and k-nearest neighbors achieved 99% accuracy in multi-class classification. The article emphasizes the critical role of feature engineering, with a specific focus on feature selection and reduction, and elaborates on applying MRMR and PCA algorithms to various feature sets. By comparing these methods, it showcases their influence on both model performance and complexity, leading to the development of more efficient and precise intrusion detection systems for Industrial IoT networks. What sets this study apart from previous ones is its novel demonstration of how these techniques significantly reduce training time and model complexity while maintaining or even improving performance, confirming the effectiveness of strategic feature utilization in strengthening Industrial IoT security by balancing accuracy, speed, and model size.

1 September 2020 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
Haipeng LiuHaipeng Liu
Haipeng Liu
FCFei Chen
Fei Chen
VHVera Hartmann
Vera Hartmann
Syed Ghufran KhalidSyed Ghufran Khalid
Syed Ghufran Khalid
SHStephen Hughes
Stephen Hughes
DZDingchang Zheng
Dingchang Zheng
Objective: Based on different physiological mechanisms, the respiratory modulations of photoplethysmography (PPG) signals differ in strength and resultant accuracy of respiratory frequency (RF) estimations. We aimed to investigate the strength of different respiratory modulations and the accuracy of resultant RF estimations in different body sites and two breathing patterns. Approach: PPG and reference respiratory signals were simultaneously measured over 60 s from 36 healthy subjects in six sites (arm, earlobe, finger, forehead, wrist-under (volar side), wrist-upper (dorsal side)). Respiratory signals were extracted from PPG recordings using four demodulation approaches: amplitude modulation (AM), baseline wandering (BW), frequency modulation (FM) and filtering. RFs were calculated from the PPG-derived and reference respiratory signals. To investigate the strength of respiratory modulations, the energy proportion in the range that covers 75% of the total energy in the reference respiratory signal, with RF in the middle, was calculated and compared between different modulations. Analysis of variance and the Scheirer–Ray–Hare test were performed with post hoc analysis. Main results: In normal breathing, FM was the only modulation whose RF was not significantly different from the reference RF (p > 0.05). Compared with other modulations, FM was significantly higher in energy proportion (p < 0.05) and lower in RF estimation error (p < 0.05). As to energy proportion, measurements from the finger and the forehead were not significantly different (p > 0.05), but both were significantly different from the other four sites (p < 0.05). In deep breathing, the RFs derived by BW, filtering and FM were not significantly different from the reference RF (p > 0.05). The RF estimation error of FM was significantly less than that of AM or BW (p < 0.05). The energy proportion of FM was significantly higher than that of other modulations (p < 0.05). Significance: Of all the respiratory modulations, FM has the highest strength and is appropriate for accurate RF estimation from PPG signals recorded at different sites and for different breathing patterns.

1 July 2021 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
Haipeng LiuHaipeng Liu
Haipeng Liu
John AllenJohn Allen
John Allen
Syed Ghufran KhalidSyed Ghufran Khalid
Syed Ghufran Khalid
FCFei Chen
Fei Chen
DZDingchang Zheng
Dingchang Zheng
Objective. The waveform of a photoplethysmography (PPG) signal depends on the measurement site and individual physiological conditions. Filtering can distort the morphology of the original PPG signal waveform and change the timing of pulse feature points on PPG signals. We aim to quantitatively investigate the effect of PPG signal morphology (related to measurement site) and type of pulse feature on the filtering-induced time shift (TS). Approach. 60 s PPG signals were measured from six body sites (finger, wrist under (volar), wrist upper (dorsal), earlobe, and forehead) of 36 healthy adults. Using infinite impulse response digital filters which are common in PPG signal processing, PPG signals were prefiltered (band-pass, pass and stop bands: >0.5 Hz and <0.2 Hz for high-pass filter, 30 Hz for low-pass filter) and then filtered (low-pass, pass and stop bands: 5 Hz). Four pulse feature points were defined and extracted (peak, valley, maximal first derivative, and maximal second derivative). For each subject, overall TS and intra-subject TS variability in feature points were calculated as the mean and standard deviation of TS between prefiltered and filtered PPG signals in 50 cardiac cycles. Statistical testing was performed to investigate the effect of measurement site and type of pulse feature on overall TS and intra-subject TS variability. Main results. Measurement site, type of pulse feature, and their interaction had significant impacts on the overall TS and intra-subject TS variability ( p < 0.001 for all). Valley and maximal second derivative showed higher overall TS than peak and maximal first derivative. Finger had higher overall TS and lower intra-subject TS variability than other measurement sites. Significance . Measurement site and type of pulse feature can significantly influence the timing of feature points on filtered PPG signals. Filtering parameters should be quoted to support the reproducibility of PPG-related studies.

5 September 2022 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
Syed Ghufran KhalidSyed Ghufran Khalid
Syed Ghufran Khalid
SASyed Mehmood Ali
Syed Mehmood Ali
Haipeng LiuHaipeng Liu
Haipeng Liu
AQAisha Ghazal Qurashi
Aisha Ghazal Qurashi
UAUzma Ali
Uzma Ali
Anesthesia drug overdose hazards and lack of gold standards in anesthesia monitoring lead to an urgent need for accurate anesthesia drug detection. To investigate the PPG waveform features affected by anesthesia drugs and develop a machine-learning classifier with high anesthesia drug sensitivity. This study used 64 anesthesia and non-anesthesia patient data (32 cases each), extracted from Queensland and MIMIC-II databases, respectively. The key waveform features (total area, rising time, width 75%, 50%, and 25%) were extracted from 16,310 signal recordings (5-s duration). Discriminant analysis, support vector machine (SVM), and K-nearest neighbor (KNN) were evaluated by splitting the dataset into halve training (11 patients, 8570 segments) and halve testing dataset (11 patients, 7740 segments). Significant differences exist between PPG waveform features of anesthesia and non-anesthesia groups (p < 0.05) except total area feature (p > 0.05). The KNN classifier achieved 91.7% (AUC = 0.95) anesthesia detection accuracy with the highest sensitivity (0.88) and specificity (0.90) as compared to other classifiers. Kohen’s kappa also shows almost perfect agreement (0.79) with the KNN classifier. The KNN classifier trained with significant PPG features has the potential to be used as a reliable, non-invasive, and low-cost method for the detection of anesthesia drugs for depth analysis during surgical operations and postoperative monitoring. Graphical abstract