Umut Yucel

Dr. Umut Yucel

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2015 in Journal of Earthquake Engineering
Verified
Journal Article
Closed access
IMIbrahim Serkan Misir
Ibrahim Serkan Misir
OOOzgur Ozcelik
Ozgur Ozcelik
Sadık Can GirginSadık Can Girgin
Sadık Can Girgin
UYUmut Yucel
Umut Yucel
Large-scale reinforced concrete frames with five different infill conditions, namely three single-leaf, two double-leaf walls with and without Z-ties, and a bare frame were tested. Under progressively increased in-plane actions, as the main aspect the behavior of walls under simultaneously acting monotonic out-of-plane loads was investigated. All infill walls have doubled the initial stiffness and energy absorption capacity of the frames, and the ultimate strength has increased about 50%. Z-ties have helped the double-leaf wall to maintain its integrity up to higher inter-story drift levels, and improve the out-of-plane stability of the wall.

27 July 2022 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Closed access
PDF file
OOOzgur OZcelik
Ozgur OZcelik
IMIbrahim Serkan Misir
Ibrahim Serkan Misir
UYUmut Yucel
Umut Yucel
EDErkan Durmazgezer
Erkan Durmazgezer
GYGokhan Yucel
Gokhan Yucel
CACarmen Amaddeo
Carmen Amaddeo

30 October 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Onur OzturkogluOnur Ozturkoglu
Onur Ozturkoglu
UYUmut Yucel
Umut Yucel
CKCihan Karademir
Cihan Karademir
EDErkan Durmazgezer
Erkan Durmazgezer
This paper aims to investigate the effect of glass fiber-reinforced polymer (GFRP) and carbon fiber-reinforced polymer (CFRP) strengthening materials on the static and dynamic behavior of reinforced concrete (R/C) beams subjected to progressive damage. Four identical beams, each strengthened with either GFRP or CFRP, are tested under a cyclic quasi-static loading pattern. Impact hammer tests are performed for undamaged states and various damage levels of the beams. The dynamic test data are analyzed using the Enhanced Frequency Domain Decomposition (EFDD) method to estimate the dynamic characteristics of the beams. In this context, the first three vibration modes in both vertical and horizontal directions are considered. Strengthening is applied to both pre-damaged and undamaged beams, enabling a comparison of their performance before and after the strengthening procedure. Beams strengthened with CFRP exhibit a higher load-bearing capacity and stiffness but also fail at lower displacement levels compared to those strengthened with GFRP, which demonstrate more ductile behavior. Furthermore, the modal frequency ratios indicate that the first vibration mode is more sensitive to damage than the second and third modes. This study highlights the effectiveness of both strengthening materials in enhancing the structural performance of both undamaged and damaged beams.

1 January 2015
Verified
Book Chapter
Closed access
PDF file
OOOzgur Ozcelik
Ozgur Ozcelik
IMIbrahim Serkan Misir
Ibrahim Serkan Misir
CACarmen Amaddeo
Carmen Amaddeo
UYUmut Yucel
Umut Yucel
EDErkan Durmazgezer
Erkan Durmazgezer

12 October 2022 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
UYUmut Yucel
Umut Yucel
EDErkan Durmazgezer
Erkan Durmazgezer
OOOzgur OZcelik
Ozgur OZcelik
IMIbrahim Serkan Misir
Ibrahim Serkan Misir

11 January 2021
Verified
Book Chapter
Closed access
PDF file
EDErkan Durmazgezer
Erkan Durmazgezer
UYUmut Yucel
Umut Yucel
OOOzgur Ozcelik
Ozgur Ozcelik