Ibrahim Serkan Misir

Prof. Dr. Ibrahim Serkan Misir

orcid
Dokuz Eylul University Civil Engineering Department

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2012 in STRUCTURAL ENGINEERING AND MECHANICS
Verified
Journal Article
Closed access
IMIbrahim Serkan Misir
Ibrahim Serkan Misir
OOOzgur Ozcelik
Ozgur Ozcelik
Sadık Can GirginSadık Can Girgin
Sadık Can Girgin
SKSerap Kahraman
Serap Kahraman

24 November 2015 in Journal of Earthquake Engineering
Verified
Journal Article
Closed access
IMIbrahim Serkan Misir
Ibrahim Serkan Misir
OOOzgur Ozcelik
Ozgur Ozcelik
Sadık Can GirginSadık Can Girgin
Sadık Can Girgin
UYUmut Yucel
Umut Yucel
Large-scale reinforced concrete frames with five different infill conditions, namely three single-leaf, two double-leaf walls with and without Z-ties, and a bare frame were tested. Under progressively increased in-plane actions, as the main aspect the behavior of walls under simultaneously acting monotonic out-of-plane loads was investigated. All infill walls have doubled the initial stiffness and energy absorption capacity of the frames, and the ultimate strength has increased about 50%. Z-ties have helped the double-leaf wall to maintain its integrity up to higher inter-story drift levels, and improve the out-of-plane stability of the wall.

22 May 2017 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
Sadık Can GirginSadık Can Girgin
Sadık Can Girgin
IMIbrahim Serkan Misir
Ibrahim Serkan Misir
SKSerap Kahraman
Serap Kahraman
Post-earthquake observations revealed that seismic performance of beam-column connections in precast concrete structures affect the overall response extensively. Seismic design of precast reinforced concrete structures requires improved beam-column connections to transfer reversed load effects between structural elements. In Turkey, hybrid beam-column connections with welded components have been applied extensively in precast concrete industry for decades. Beam bottom longitudinal rebars are welded to beam end plates while top longitudinal rebars are placed to designated gaps in joint panels before casting of topping concrete in this type of connections. The paper presents the major findings of an experimental test programme including one monolithic and five precast hybrid half scale specimens representing interior beam-column connections of a moment frame of high ductility level. The required welding area between beam bottom longitudinal rebars and beam-end plates were calculated based on welding coefficients considered as a test parameter. It is observed that the maximum strain developed in the beam bottom flexural reinforcement plays an important role in the overall behavior of the connections. Two additional specimens which include unbonded lengths on the longitudinal rebars to reduce that strain demands were also tested. Strength, stiffness and energy dissipation characteristics of test specimens were investigated with respect to test variables. Seismic performances of test specimens were evaluated by obtaining damage indices.

1 October 2015 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
IMIbrahim Serkan Misir
Ibrahim Serkan Misir

27 July 2022 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Closed access
PDF file
OOOzgur OZcelik
Ozgur OZcelik
IMIbrahim Serkan Misir
Ibrahim Serkan Misir
UYUmut Yucel
Umut Yucel
EDErkan Durmazgezer
Erkan Durmazgezer
GYGokhan Yucel
Gokhan Yucel
CACarmen Amaddeo
Carmen Amaddeo

4 February 2023 in Buildings
Verified
Journal Article
Open access
PDF file
IMIbrahim Serkan Misir
Ibrahim Serkan Misir
GYGokhan Yucel
Gokhan Yucel
Failure under seismic action generally occurs in the form of out-of-plane collapses of walls before reaching their in-plane strength in historical stone masonry buildings. Consistent finite element (FE) macro modeling has emerged as a need for use in seismic assessments of these walls. This paper presents the numerical model calibration of U-shaped multi-leaf stone masonry wall specimens tested under ambient vibrations and out-of-plane (OOP) load reversals. The uncertain elastic parameters were obtained by manual calibration of the numerical models based on ambient vibration test (AVT) data of the specimens. To obtain nonlinear calibration parameters, static pushover analyses were performed on FE models simulating quasi-static tests. The calibrated numerical models matched well with the experimental results in terms of load–drift response and damage distribution. As a result, the modulus of elasticity and tensile and compressive degrading strength parameters of masonry walls were proposed. A parametric study was conducted to examine the effects of different materials and geometric properties (tensile strength, aspect ratio, slenderness ratio, and geometric scale) on the OOP behavior of stone masonry walls. A quite different strain distribution was obtained in the case of a large aspect ratio, while it was determined that the geometric scale had no effect on the strain distribution. Tensile strength was the dominant parameter affecting the load–drift response of the models. Within the presented work, a practical tool for out-of-plane seismic assessment has been proposed for the structures covered in this paper.