Particulate matter (PM2.5, PM10) in urban subway stations can significantly impact passengers' health. The particle concentration in subway stations is influenced by many factors. However, few existing studies have explored the impact of environmental control systems in-depth, especially under different outdoor pollution conditions. To address this research gap, this study focused on measuring and comparing the characteristics of PM2.5 and PM10 at subway stations with three control systems (open, closed, and screen door) under varying pollution conditions in Beijing. Particle concentrations from platforms, carriages, and outdoors were monitored and analyzed using statistical methods. The results showed that the particle concentration in the closed system was generally 20–40 μg/m3 higher than that in the screen system at the platform, which might be attributed to the piston wind, as the air from the tunnel with a lot of dirt. The pollution in the carriage was more severe for the open system than that of the screen system. The PM2.5/PM10 ratio in the carriage was 91%, 90%, and 83.84% for the closed, open, and screen systems, respectively. This indicates that the screen door could reduce the particle concentration in the platform to 10%–50%. The particle concentration varied among subway stations with different environmental control systems, suggesting that the prevention and control strategies for particulate matter pollution should be different for stations with different systems.
Although much research is being conducted on the characteristics of PM2.5 and PM10 at subway stations, there is no research focusing on a complex subway transfer station. In this paper, the characteristics of PM2.5 and PM10 at transfer stations are studied. For comparison, monitoring is performed under different outside conditions at four different transfer stations in the non-peak period during March 2018. The concentrations of PM2.5 and PM10 on the platform in the transfer stations is approximately 10 μg/m3 lower than in the non-transfer station, when outside PM2.5 is lower than 150 μg/m3. However, the ratio of PM2.5 to PM10 at the transfer stations (lowest: 78.1%) is higher than at the non-transfer station (lowest: 61.2%), indicating that the PM10 content differs from the non-transfer station. In a transfer station with the same depth, the PM concentration is the same or similar. In addition, the concentration of PM2.5 at subway stations has a strong correlation with the outside environment (R2 = 0.897), which indicates that an outside condition is important for the subway environment.
14 January 2024 in Journal of Building Engineering