Ahmed Elyamani

Dr. Ahmed Elyamani

Architectural Conservation, Cairo University, Giza, Al Jīzah, Egypt
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2016 in Structural Control and Health Monitoring
Verified
Journal Article
Closed access
PDF file
Ahmed ElyamaniAhmed Elyamani
Ahmed Elyamani
OCOriol Caselles
Oriol Caselles
PRPere Roca
Pere Roca
JCJaime Clapes
Jaime Clapes

1 April 2017 in Engineering Failure Analysis
Verified
Journal Article
Open access
Ahmed ElyamaniAhmed Elyamani
Ahmed Elyamani
PRPere Roca
Pere Roca
OCOriol Caselles
Oriol Caselles
JCJaime Clapes
Jaime Clapes
The paper presents an integrated approach aimed at assessing the seismic safety of Mallorca cathedral. This cathedral is an extraordinary historical construction dating back to the middle-ages. The experimental modal parameters of the cathedral were identified using Ambient Vibration Testing (AVT). The cathedral numerical model was updated using the identified modal parameters. This updated model was then used to study the seismic response of the cathedral using non-linear static (pushover) analysis. A sensitively analysis was carried out to reveal the dependency of the seismic capacity on the input materials properties. To assess the seismic performance and the safety of the cathedral, the N2 method was employed. It was found that the cathedral is safe when subjected to the earthquakes expected in Mallorca Island.Peer ReviewedPostprint (author's final draft

16 July 2021 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
AEAhmed Elghazouli
Ahmed Elghazouli
DBDan Bompa
Dan Bompa
SMSherif A. Mourad
Sherif A. Mourad
Ahmed ElyamaniAhmed Elyamani
Ahmed Elyamani
This paper presents an experimental investigation into the structural and material response of ambient-dry and wet clay-brick/lime-mortar masonry elements. In addition to cyclic tests on four large-scale masonry walls subjected to lateral in-plane displacement and co-existing compressive gravity load, the study also includes complementary tests on square masonry panels under diagonal compression and cylindrical masonry cores in compression. After describing the specimen details, wetting method and testing arrangements, the main results and observations are provided and discussed. The results obtained from full-field digital image correlation measurements enable a detailed assessment of the material shear-compression strength envelope, and permit a direct comparison with the strength characteristics of structural walls. The full load-deformation behaviour of the large-scale walls is also evaluated, including their ductility and failure modes, and compared with the predictions of available assessment models. It is shown that moisture has a notable effect on the main material properties, including the shear and compression strengths, brick–mortar interaction parameters, and the elastic and shear moduli. The extent of the moisture effects is a function of the governing behaviour and material characteristics as well as the interaction between shear and precompression stresses, and can lead to a loss of more than a third of the stiffness and strength. For the large scale wall specimens subjected to lateral loading and co-existing compression, the wet-to-dry reduction was found to be up to 20% and 11% in terms of stiffness and lateral strength, respectively, whilst the ductility ratio diminished by up to 12%. Overall, provided that the key moisture-dependent material properties are appropriately evaluated, it is shown that analytical assessment methods can be reliably adapted for predicting the response, in terms of the lateral stiffness, strength and overall load-deformation, for both dry and wet masonry walls.

11 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
ARAhmad Reda
Ahmad Reda
Ahmed ElyamaniAhmed Elyamani
Ahmed Elyamani
AEAdel G. El-Attar
Adel G. El-Attar
DBDan Bompa
Dan Bompa
AEAhmed Elghazouli
Ahmed Elghazouli
SMSherif A. Mourad
Sherif A. Mourad
Historic Cairo has been a UNESCO World Heritage Site since 1979. It has more than 600 historic structures, which require extensive studies to sustain their cultural, religious, and economic values. The main aim of this paper is to undertake dynamic investigation tests for the dome of Fatima Khatun, a historic mausoleum in Historic Cairo dating back to the 13th century and consisting of mainly bricks and stones. The challenge was that the structure was difficult to access, and only a small portion of the top was accessible for the attachment of accelerometers. Current dynamic identification procedures typically adopt methods in which the sensors are arranged at optimal locations and permit direct assessment of the natural frequencies, mode shapes, and damping ratios of a structure. Approaches that allow for the evaluation of dynamic response for structures with limited accessibility are lacking. To this end, in addition to in situ dynamic investigation tests, a numerical model was created based on available architectural, structural, and material documentation to obtain detailed insight into the dominant modes of vibration. The free vibration analysis of the numerical model identified the dynamic properties of the structure using reasonable assumptions on boundary conditions. System identification, which was carried out using in situ dynamic investigation tests and input from modelling, captured three experimental natural frequencies of the structure with their mode shapes and damping ratios. The approach proposed in this study informs and directs structural restoration for the mausoleum and can be used for other heritage structures located in congested historic sites.

23 October 2023 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
AEAhmed Elghazouli
Ahmed Elghazouli
DBDan Bompa
Dan Bompa
SMSherif A. Mourad
Sherif A. Mourad
Ahmed ElyamaniAhmed Elyamani
Ahmed Elyamani
This paper studies the response of unreinforced masonry (URM) members made of hydraulic lime mortar and fired clay bricks, commonly found in heritage structures, strengthened with textile reinforced mortar (TRM) overlays. The investigation includes URM and TRM-strengthened diagonal compression tests on square panels, and relatively large-scale wall specimens subjected to combined gravity and lateral cyclic loads. Complementary compression, tension, and interface material tests are also carried out. The diagonal panel tests show that the TRM effectiveness depends in a non-proportional manner on the overlays, render thickness, and substrate strength. The enhancement in stiffness, strength, and ultimate shear strain, using one to four mesh layers on each side, is shown to vary in the range of 49–132%, 102–536%, and 300–556% respectively. It is shown that strut crushing typically governs the response of such low-strength URM masonry elements confined by TRM overlays. The cyclic tests on the comparatively larger walls show that the TRM is effective, shifting the response from URM diagonal tension to rocking, and enhancing the stiffness, strength, and ultimate drift capacity by more than 160%, 30%, and 130%, respectively. It is shown that analytical assessment methods for predicting the response of TRM-strengthened and URM members in terms of stiffness, strength and load-deformation can be reliably adapted. The cumulative contribution of the URM and TRM components, in conjunction with a suitable fibre textile strain, is also found to offer an improved prediction of the shear strength compared to codified procedures. The findings enable the evaluation and improvement of analytical models for determining the main inelastic response parameters of TRM-strengthened masonry and provide information for validating future detailed nonlinear numerical simulations.

20 October 2022 in SN Applied Sciences
Verified
Journal Article
Open access
PDF file
MHMaha Hassan
Maha Hassan
Ahmed ElyamaniAhmed Elyamani
Ahmed Elyamani
SMSherif A. Mourad
Sherif A. Mourad
This work intends to provide seismic vulnerability analysis for a building stock in Al Khalifa District, Fatimid Cairo while focusing on the historic buildings in the area. The work represents part of an interdisciplinary study targeting the management and conservation of a UNESCO World Heritage Site. The project inspects several aspects including behavior of masonry walls, structural health monitoring of selected structures, conservation studies, in addition to influence of rising ground water. In the current study, seismicity of Egypt generally and Cairo specifically is reviewed. Afterwards, large-scale seismic vulnerability is adopted to calculate the vulnerability index for buildings within the study area. Data are collected through extensive on-site surveys for more than one hundred buildings. Observed typologies are listed alongside possible mechanisms of failure. Egypt has moderate seismic hazard; however, many buildings are prone to damage due to inadequate seismic design. This leads to retrofitting requirements to reduce seismic vulnerability and adhere to imposed seismic requirements in design codes. The study is intended to understand seismic risk of buildings within study area as part of a comprehensive study. Developed vulnerability map show that many buildings are prone to damage during seismic events. Article Highlights: Seismic vulnerability of building samples in a study area within Old Cairo is assessed and presented in the form of a vulnerability map. Structural characteristics of buildings are detailed and investigated. Signs of deterioration are analyzed, and mechanisms of failure are featured.