Amaya Paz de la vega Quiroz

Ms. Amaya Paz de la vega Quiroz

Departamento de Química de los Materiales, Universidad de Santiago de Chile, Santiago, Región Metropolitana, Chile
orcid
Mg. and PhD(c).

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Food Chemistry
Verified
Journal Article
Closed access
FLFabiana Andrea Liendo
Fabiana Andrea Liendo
AQAmaya Paz de la vega Quiroz
Amaya Paz de la vega Quiroz
MAMaria Jesus Aguirre
Maria Jesus Aguirre
FGFernando Godoy
Fernando Godoy
AMAngel A. Martí
Angel A. Martí
RSRodrigo Segura
Rodrigo Segura

Verified
Journal Article
Open access
PDF file
AQAmaya Paz de la vega Quiroz
Amaya Paz de la vega Quiroz
FLFabiana Andrea Liendo
Fabiana Andrea Liendo
BPBryan Hernán Pichún
Bryan Hernán Pichún
JLJohisner Penagos Llanos
Johisner Penagos Llanos
RSRodrigo Segura
Rodrigo Segura
MAMaria Aguirre
Maria Aguirre
Designing a highly sensitive and efficient functionalized electrode for precise drug analysis remains a significant challenge. In this work, an electrochemical sensor based on a glassy carbon electrode (GCE) modified with phenyl diazonium salts (ph) and electrochemically reduced graphene oxide (ERGO), labeled GCE/ph/ERGO, was developed for the detection of paracetamol (PAR) in pharmaceutical matrices using square wave voltammetry (SWV). The modified electrode was characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Compared to the bare GCE, the GCE/ph/ERGO sensor demonstrated significantly improved conductivity and anodic current peak for PAR over two orders of magnitude higher, indicating a substantial enhancement in electrochemical performance. Under optimized conditions, the developed sensor exhibited a low detection limit of 18.2 nM and a quantification limit of 60.6 nM. Precision studies yielded relative standard deviations (RSDs) below 8%. The sensor demonstrated excellent selectivity in the presence of common pharmaceutical excipients and high accuracy in the analysis of generic pharmaceutical formulations, with results comparable to those obtained by the HPLC technique. These findings confirm the sensor’s reliability, stability, robustness, and suitability for routine analysis of PAR in pharmaceutical samples.

9 September 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
FLFabiana Andrea Liendo
Fabiana Andrea Liendo
BPBryan Hernán Pichún
Bryan Hernán Pichún
AQAmaya Paz de la vega Quiroz
Amaya Paz de la vega Quiroz
JLJohisner Penagos Llanos
Johisner Penagos Llanos
Núria SerranoNúria Serrano
Núria Serrano
MAMaria Aguirre
Maria Aguirre
In this study, a new and simple glassy carbon electrode modified with carbon nanohorns (SWCNH/GCE) was used for the determination of Cr(VI) in aqueous matrices via adsorptive cathodic stripping voltammetry (AdCSV). The modified electrode was characterized via field emission scanning electron microscopy and cyclic voltammetry, which revealed a homogeneous distribution of spherical agglomerates of SWCNH on the electrode surface. The modification increased the electrochemically active area from 0.10 cm2 ± 0.01 (GCE) to 0.16 cm2 ± 0.01 (SWCNH/GCE). The optimized analytical conditions were as follows: a supporting electrolyte (0.15 mol L−1 HCl), an accumulation potential of 0.8 V versus Ag/AgCl, and an accumulation time of 240 s. Validation of the analytical methodology was performed, obtaining a linear range between 20 and 100 µg L−1, a limit of detection of 3.5 µg L−1, and a limit of quantification of 11.6 µg L−1 with good accuracy and precision. The method was applied to the analysis of spiked tap water samples, and the results were compared using a flame atomic absorption spectrophotometer (FAAS) with no significant statistical differences.

30 May 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
JLJohisner Penagos Llanos
Johisner Penagos Llanos
RSRodrigo Segura
Rodrigo Segura
AQAmaya Paz de la vega Quiroz
Amaya Paz de la vega Quiroz
BPBryan Hernán Pichún
Bryan Hernán Pichún
FLFabiana Andrea Liendo
Fabiana Andrea Liendo
ENEdgar Nagles
Edgar Nagles
This paper presents an application for a molybdenum disulfide nanomaterial with multiwalled carbon nanotubes (MoS2@MWCNT/E) in a modified electrode substrate for the detection of uric acid (UA). The modified electrode generates a substantial three-fold increase in the anodic peak current for UA compared to the unmodified MWCNT electrode (MWCNT/E). The MoS2@MWCNT/E surface was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS) and electrochemical impedance spectroscopy (EIS). The achieved detection limit stood at 0.04 µmol/L, with a relative standard deviation (RSD) of 2.0% (n = 10). The method’s accuracy, assessed through relative error and percent recovery, was validated using a urine standard solution spiked with known quantities of UA.

19 November 2022 in Microorganisms
Verified
Journal Article
Open access
PDF file
MAMaialen Aldabaldetrecu
Maialen Aldabaldetrecu
MPMick Parra
Mick Parra
SSSarita Soto-Aguilera
Sarita Soto-Aguilera
PAPablo Arce
Pablo Arce
AQAmaya Paz de la vega Quiroz
Amaya Paz de la vega Quiroz
BMBrenda Modak
Brenda Modak
Previously, we reported an in vitro evaluation regarding antibacterial effects against F. psychrophilum by a new Cu (I) complex, [Cu(NN1)2](ClO4). This study presents the results of an in vivo evaluation of [Cu(NN1)2](ClO4) added as a dietary supplement against F. psychrophilum in rainbow trout. The results showed that the administration of [Cu(NN1)2](ClO4) at 29 and 58 µg/g of fish for 15 days does not affect the growth of rainbow trout. On the other hand, the amount of copper present in the liver, intestine, and muscle of rainbow trout was determined. The results showed that the amount of copper in the liver, when compared between treated fish and control fish, does not change. While, in the intestine, an increase in the fish fed at 58 µg/g of fish was observed. In muscle, a slight decrease at 29 µg/g was obtained. Additionally, copper concentrations in the pond water after 15 days of feeding with the [Cu(NN1)2](ClO4) complex showed the highest levels of copper. Finally, the effect of the administration of [Cu(NN1)2](ClO4) for 15 days at 58 µg/g of fish was evaluated against F. psychrophilum, where a 75% survival was obtained during 20 days of challenge.

1 December 2013 in Journal of the Chilean Chemical Society
Verified
Journal Article
Open access
PDF file
AQAmaya Paz de la vega Quiroz
Amaya Paz de la vega Quiroz
DADiego A Alarcón
Diego A Alarcón
JGJuan S Gómez-Jeria
Juan S Gómez-Jeria