Angkoon Khaohoen

Dr. Angkoon Khaohoen

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2024 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Angkoon KhaohoenAngkoon Khaohoen
Angkoon Khaohoen
WPWarit Powcharoen
Warit Powcharoen
TSTanapon Sornsuwan
Tanapon Sornsuwan
PCPisaisit Chaijareenont
Pisaisit Chaijareenont
CRChaiy Rungsiyakull
Chaiy Rungsiyakull
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
This systematic review explores the accuracy of computerized guided implant placement including computer-aided static, dynamic, and robot-assisted surgery. An electronic search up to February 28, 2023, was conducted using the PubMed, Embase, and Scopus databases using the search terms “surgery”, “computer-assisted”, “dynamic computer-assisted”, “robotic surgical procedures”, and “dental implants”. The outcome variables were discrepancies including the implant’s 3D-coronal, -apical and -angular deviations. Articles were selectively retrieved according to the inclusion and exclusion criteria, and the data were quantitatively meta-analysed to verify the study outcomes. Sixty-seven articles were finally identified and included for analysis. The accuracy comparison revealed an overall mean deviation at the entry point of 1.11 mm (95% CI: 1.02–1.19), and 1.40 mm (95% CI: 1.31–1.49) at the apex, and the angulation was 3.51˚ (95% CI: 3.27–3.75). Amongst computerized guided implant placements, the robotic system tended to show the lowest deviation (0.81 mm in coronal deviation, 0.77 mm in apical deviation, and 1.71˚ in angular deviation). No significant differences were found between the arch type and flap operation in cases of dynamic navigation. The fully-guided protocol demonstrated a significantly higher level of accuracy compared to the pilot-guided protocol, but did not show any significant difference when compared to the partially guided protocol. The use of computerized technology clinically affirms that operators can accurately place implants in three directions. Several studies agree that a fully guided protocol is the gold standard in clinical practice.

3 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Angkoon KhaohoenAngkoon Khaohoen
Angkoon Khaohoen
TSTanapon Sornsuwan
Tanapon Sornsuwan
PCPisaisit Chaijareenont
Pisaisit Chaijareenont
PPPongsakorn Poovarodom
Pongsakorn Poovarodom
CRChaiy Rungsiyakull
Chaiy Rungsiyakull
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
Titanium has been the material of choice for dental implant fixtures due to its exceptional qualities, such as its excellent balance of rigidity and stiffness. Since zirconia is a soft-tissue-friendly material and caters to esthetic demands, it is an alternative to titanium for use in implants. Nevertheless, bone density plays a vital role in determining the material and design of implants. Compromised bone density leads to both early and late implant failures due to a lack of implant stability. Therefore, this narrative review aims to investigate the influence of implant material/design and surgical technique on bone density from both biomechanical and biological standpoints. Relevant articles were included for analysis. Dental implant materials can be fabricated from titanium, zirconia, and PEEK. In terms of mechanical and biological aspects, titanium is still the gold standard for dental implant materials. Additionally, the macro- and microgeometry of dental implants play a role in determining and planning the appropriate treatment because it can enhance the mechanical stress transmitted to the bone tissue. Under low-density conditions, a conical titanium implant design, longer length, large diameter, reverse buttress with self-tapping, small thread pitch, and deep thread depth are recommended. Implant material, implant design, surgical techniques, and bone density are pivotal factors affecting the success rates of dental implant placement in low-density bone. Further study is required to find the optimal implant material for a clinical setting’s bone state.

10 April 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
Angkoon KhaohoenAngkoon Khaohoen
Angkoon Khaohoen
WPWarit Powcharoen
Warit Powcharoen
NYNobuhiro Yoda
Nobuhiro Yoda
CRChaiy Rungsiyakull
Chaiy Rungsiyakull
PRPimduen Rungsiyakull
Pimduen Rungsiyakull

Verified
Journal Article
Open access
PDF file
TLTin Thinzar Linn
Tin Thinzar Linn
Angkoon KhaohoenAngkoon Khaohoen
Angkoon Khaohoen
Khaing Myat ThuKhaing Myat Thu
Khaing Myat Thu
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
Background: The improvement of oral-health-related quality of life (OHRQoL) with different types of prosthesis for completely edentulous jaws in the elderly population is a critical factor in clinical decision making for these vulnerable patients. This review aims to evaluate the changes in OHRQoL after treatment with different types of full-arch prostheses in the elderly edentulous population to determine the prostheses that result in the greatest improvement in OHRQoL. Materials and Methods: Clinical studies of different types of full-arch prostheses that measured the OHRQoL in edentulous patients 60 years or older were searched for in the PubMed, Embase and Scopus electronic databases, with additional hand searching to summarize the outcomes of the selected studies. Result: Among the 302 identified studies, 10 studies were selected. A total of 504 patients wearing 133 complete dentures, 372 implant overdentures and 39 fixed prostheses were assessed among the selected studies. The overall OHIP and GOHAI scores were evaluated at baseline and in the 3rd, 6th, 12th and 18th months of treatment with the respective prostheses. The improved OHRQoL with overall OHIP scores associated with conventional dentures were 9.21–12.5% from the 3rd month to 1 year after treatment, whereas those associated with implant overdentures and full-arch fixed prosthesis were 9–25.26% at 1 year and 18.53–26.79 at the 18th-month follow-up, respectively. The increased overall GOHAI scores were 21.3–25.43% for conventional dentures, 36.82–41.32% for implant overdentures and 39.48–42.83% for full-arch fixed prosthesis from the 3rd month to the 6th-month follow-up. Conclusion: In general, the improvement in OHRQoL after rehabilitation with implant overdentures declined at one year, and that with full-arch fixed prosthesis declined at the 18th-month follow-up; meanwhile, the OHRQoL associated with conventional dentures improved stably up to one year, but the implant-supported prostheses resulted in an obviously greater improvement in the OHRQoL than that obtained with conventional dentures. However, studies with longer follow-up periods are still required to evaluate the long-term clinical effectiveness.

11 December 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Angkoon KhaohoenAngkoon Khaohoen
Angkoon Khaohoen
NYNobuhiro Yoda
Nobuhiro Yoda
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
CRChaiy Rungsiyakull
Chaiy Rungsiyakull
TTTaichi Tenkumo
Taichi Tenkumo
This review aims to explore the application of AI (artificial intelligence) in fixed prosthodontics and implant-supported fixed restorations, with a specific focus on the accuracy, effectiveness, and clinical applicability of AI models for optimizing treatment planning and predicting clinical outcomes. This review followed the PCC (Population, Concept, Context) framework. A systematic search was conducted using PubMed, Scopus, and Embase for studies published between January 2010 and July 2025. Keywords included “artificial intelligence,”, “deep learning”, “digital dentistry”, “prosthodontic treatment planning,” “clinical decision support,” and “outcome prediction.” The initial databases search yielded 834 results. After selection, 20 studies were included for analysis in this review. AI applications were grouped into four domains: implant planning, crown design, full-arch framework optimization, and prognostic modeling. Convolutional neural networks (CNNs), generative adversarial networks (GANs), regression models, and optimization algorithms were most frequently employed. In implant planning, AI achieved high accuracies (90–99.5%) for site detection, drilling protocols, and bone assessment. Crown design studies demonstrated occlusal and morphological deviations within clinically acceptable thresholds (0.18–0.30 mm) and mean internal gaps of 59–83 μm, while reducing design time by up to fourfold compared with conventional workflows. For full-arch prosthetics, optimization methods such as particle swarm optimization (PSO) and bi-evolutionary structural optimization (BESO) enhanced efficiency and reduced stress concentration in simulated workflows. Prognostic modeling showed promising performance, with models achieving over 90% accuracy in predicting implant survival and treatment outcomes. AI applications in prosthodontics are most developed in implant site planning and crown design, with fewer studies on full-arch optimization and prognosis. Models generally achieve high accuracy and efficiency, but most evidence is early-stage and simulation-based. Future research should focus on prospective validation, multimodal integration, and patient-centered outcomes to ensure clinical reliability.

1 January 2026 in Journal of Prosthodontic Research
Verified
Journal Article
Open access
PDF file
Angkoon KhaohoenAngkoon Khaohoen
Angkoon Khaohoen
NYNobuhiro Yoda
Nobuhiro Yoda
PPPinyo Puangmali
Pinyo Puangmali
CRChaiy Rungsiyakull
Chaiy Rungsiyakull
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
Purpose: This review examined clinical and technological factors that influence implant placement accuracy in computer-assisted implant surgery (CAIS) systems.Study selection: A systematic search of PubMed, Scopus, and Embase identified English-language studies published between January 2015 and January 2025. The eligible studies included randomized controlled trials, observational studies, systematic reviews, in vitro investigations, and case reports. Data extraction focused on the coronal, apical, and angular deviations. Methodological quality was appraised using the Oxford Centre for Evidence-Based Medicine (CEBM) framework and validated bias assessment tools.Results: Fifty-three studies were included. Accuracy was influenced by patient-related factors (arch type, bone density, and edentulous span), surgical variables (flap design, operator experience, and guide protocol), and technological parameters (imaging modality, fiducial markers, and calibration). Static systems achieved high accuracy in dentate cases with stable guide support, but were less reliable in posterior or edentulous jaws. Dynamic navigation provided intraoperative flexibility and consistent performance across arches, although outcomes depended on calibration precision and operator learning curves. Robotic-assisted systems achieved the lowest mean deviations through trajectory control and haptic feedback, although evidence remains limited to early clinical and in vitro studies.Conclusions: Although all CAIS systems achieve high accuracy, their performance varies according to the design of the system and clinical context. Static systems are effective when stabilization is ensured, while dynamic navigation offers adaptable accuracy across scenarios, and robotics exhibit the greatest consistency by reducing operator variability. Further multicenter randomized trials and standardized reporting are needed to strengthen the available evidence and guide clinical selection.