Pisaisit Chaijareenont

Dr. Pisaisit Chaijareenont

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2024 in Metals
Verified
Journal Article
Open access
PDF file
STSivakorn Tuikampee
Sivakorn Tuikampee
PCPisaisit Chaijareenont
Pisaisit Chaijareenont
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
AYApichai Yavirach
Apichai Yavirach
Surface modifications for titanium, a material of choice for dental implants, can greatly alter the surface micro/nanotopography and composition of implants, leading to notable enhancements in their hydrophilicity, mechanical properties, osseointegration performance, and antibacterial performance, as well as their impacts on osteoblast activity and bone formation processes. This article aims to update titanium surface modification techniques for dental implants from the past to the present, along with their effects on osteoblasts and bone formation, by thoroughly summarizing findings from published studies. Peer-reviewed articles published in English consisting of in vitro, in vivo, and clinical studies on titanium dental implant surface treatments were searched in Google Scholar, PubMed/MEDLINE, ScienceDirect, and the Scopus databases from January 1983 to December 2023 and included in this review. The previous studies show that implant surface roughness, condition, and hydrophilicity are crucial for osteoblast adhesion and growth. While various techniques enhance osseointegration comparably, one of the most common approaches to accomplishing these properties is sandblasting large-grit acid etching surface treatment and coating with hydroxyapatite or chitosan. In conclusion, this review points out the efficacy of different subtraction and addition techniques in enhancing the surface properties of titanium dental implants, promoting favorable outcomes in terms of osteoblast activity and bone formation in various degrees. However, most existing studies predominantly compare treated and non-treated titanium, revealing a need for more comprehensive studies comparing the effects of various modification techniques. Moreover, further investigation of factors playing a role in the dynamic osseointegration process in addition to osteoblasts and their functions, as well as improved surface modification techniques for the treatment of compromised patients, is greatly required.

3 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Angkoon KhaohoenAngkoon Khaohoen
Angkoon Khaohoen
TSTanapon Sornsuwan
Tanapon Sornsuwan
PCPisaisit Chaijareenont
Pisaisit Chaijareenont
PPPongsakorn Poovarodom
Pongsakorn Poovarodom
CRChaiy Rungsiyakull
Chaiy Rungsiyakull
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
Titanium has been the material of choice for dental implant fixtures due to its exceptional qualities, such as its excellent balance of rigidity and stiffness. Since zirconia is a soft-tissue-friendly material and caters to esthetic demands, it is an alternative to titanium for use in implants. Nevertheless, bone density plays a vital role in determining the material and design of implants. Compromised bone density leads to both early and late implant failures due to a lack of implant stability. Therefore, this narrative review aims to investigate the influence of implant material/design and surgical technique on bone density from both biomechanical and biological standpoints. Relevant articles were included for analysis. Dental implant materials can be fabricated from titanium, zirconia, and PEEK. In terms of mechanical and biological aspects, titanium is still the gold standard for dental implant materials. Additionally, the macro- and microgeometry of dental implants play a role in determining and planning the appropriate treatment because it can enhance the mechanical stress transmitted to the bone tissue. Under low-density conditions, a conical titanium implant design, longer length, large diameter, reverse buttress with self-tapping, small thread pitch, and deep thread depth are recommended. Implant material, implant design, surgical techniques, and bone density are pivotal factors affecting the success rates of dental implant placement in low-density bone. Further study is required to find the optimal implant material for a clinical setting’s bone state.

Verified
Journal Article
Open access
PDF file
PCParima Chokaree
Parima Chokaree
PPPongsakorn Poovarodom
Pongsakorn Poovarodom
PCPisaisit Chaijareenont
Pisaisit Chaijareenont
AYApichai Yavirach
Apichai Yavirach
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
Customized healing abutments have been introduced in clinical practice along with implant surgery to preserve or create natural-appearing hard and soft tissue around the implant. This provides the benefits of reducing the overall treatment time by eliminating the second stage and reducing the elapsed time of the fabrication of the final prostheses. This article aims to review the types and properties of materials used for the fabrication of customized healing abutments and their clinical applications. Articles published in English on customized healing abutments were searched in Google Scholar, PubMed/MEDLINE, ScienceDirect, and the Scopus databases up to August 2022. The relevant articles were selected and included in this literature review. Customized healing abutments can be fabricated from materials available for dental implants, including PEEK, PMMA, zirconia, resin composite, and titanium. All the materials can be used following both immediate and delayed implant placement. Each material provides different mechanical and biological properties that influence the peri-implant tissues. In conclusion, the studies have demonstrated promising outcomes for all the materials. However, further investigation comparing the effects of each material on peri-implant soft and hard tissues is required.

Verified
Journal Article
Open access
PDF file
SSSuphachai Suphangul
Suphachai Suphangul
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
CKchatruethai Kanchanasobhana
chatruethai Kanchanasobhana
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
PCPisaisit Chaijareenont
Pisaisit Chaijareenont
Polyetheretherketone (PEEK) has become a useful polymeric biomaterial due to its superior properties and has been increasingly used in dentistry, especially in prosthetic dentistry and dental implantology. Promising applications of PEEK in dentistry are dental implants, temporary abutment, implant-supported provisional crowns, fixed prosthesis, removable denture framework, and finger prosthesis. PEEK as a long-term provisional implant restoration has not been studied much. Hence, this review article aims to review PEEK as a long-term provisional implant restoration for applications focusing on implant dentistry. Articles published in English on PEEK biomaterial for long-term provisional implant restoration were searched in Google Scholar, ScienceDirect, PubMed/MEDLINE, and Scopus. Then, relevant articles were selected and included in this literature review. PEEK presents suitable properties for various implant components in implant dentistry, including temporary and long-term provisional restorations. The modifications of PEEK result in wider applications in clinical dentistry. The PEEK reinforced by 30–50% carbon fibers can be a suitable material for the various implant components in dentistry.

2 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PCParima Chokaree
Parima Chokaree
PPPongsakorn Poovarodom
Pongsakorn Poovarodom
PCPisaisit Chaijareenont
Pisaisit Chaijareenont
PRPimduen Rungsiyakull
Pimduen Rungsiyakull
This study aimed to evaluate the effect of customized healing abutments compared to prefabricated healing abutments in immediate implant sites. Twelve patients requiring single immediate implant placement were divided into two groups: a prefabricated group received prefabricated titanium healing abutments, and a customized group received a polyetheretherketone (PEEK) customized healing abutments fabricated based on the individuals’ digital impressions. Outcomes, including peri-implant horizontal and vertical soft tissue alteration, bone level change, volume change, pain score, and pink esthetic score (PES) change, were evaluated at the 1-, 4-, and 6-month follow-ups compared to pre-extraction teeth. At the 1- and 4-month follow-ups, the customized group had a significantly lower buccal volume variation (BVv). At the 6-month follow-up, neither group showed any significant difference in the marginal bone change; however, the customized group had a significantly lower PES change and a lower pain score. In the anterior and premolar regions, the customized group showed the preservation of peri-implant buccal horizontal soft tissue and buccal volume, while in the molar regions, the preservation of papilla height and midfacial height was observed. The morphology of the customized healing abutment demonstrated a better trend in preservation of peri-implant soft tissue, esthetic outcomes, and lower patient discomfort in immediate implant sites.

15 April 2021 in Antibiotics
Verified
Journal Article
Open access
PDF file
SOSiriporn Okonogi
Siriporn Okonogi
PPPIMPAK PHUMAT
PIMPAK PHUMAT
SKSakornrat Khongkhunthian
Sakornrat Khongkhunthian
KSKullapop - Suttiat
Kullapop - Suttiat
PCPisaisit Chaijareenont
Pisaisit Chaijareenont
Candida albicans is a common overgrowth in people wearing dentures. Long-term use of antifungal chemicals carries a risk of toxic side effects. This study focused on the edible Piper betle extract because of its safety. The broth dilution method was applied for antifungal determination of the ethyl acetate fractionated extract (fEA) and fEA-loaded polymeric micelles (PMF). The PMF was prepared by thin-film hydration using poloxamer 407 as a polymer base. The results found that the weight ratio of fEA to polymer is the main factor to obtain PMF system as a clear solution, nanoparticle sizes, narrow size distribution, negative zeta potential, and high entrapment efficiency. The activity of PMF against C. albicans is significantly higher than fEA alone, with a minimum fungicidal concentration of 1.5 mg/mL. PMF from 1:3 ratio of fEA to polymer is used to develop a denture-soaking solution contained 1.5 mg fEA/mL (PMFS). A clinical study on dentures of 15 volunteers demonstrated an 86.1 ± 9.2% reduction of C. albicans after soaking the dentures in PMFS daily for 14 days. Interestingly, PMFS did not change the hardness and roughness of the denture base resins. The developed PMFS may serve as a potential natural denture-soaking solution against candidiasis in denture wearers.