Arijit Karmakar

Dr. Arijit Karmakar

KU Leuven, Leuven, Belgium
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2021 in Radiation
Verified
Journal Article
Open access
PDF file
AKArijit Karmakar
Arijit Karmakar
JWJialei Wang
Jialei Wang
JPJeffrey Prinzie
Jeffrey Prinzie
Valentijn De SmedtValentijn De Smedt
Valentijn De Smedt
Paul LerouxPaul Leroux
Paul Leroux
This article provides a review of semiconductor based ionising radiation sensors to measure accumulated dose and detect individual strikes of ionising particles. The measurement of ionising radiation (γ-ray, X-ray, high energy UV-ray and heavy ions, etc.) is essential in several critical reliability applications such as medical, aviation, space missions and high energy physics experiments considering safety and quality assurance. In the last few decades, numerous techniques based on semiconductor devices such as diodes, metal-oxide-semiconductor field-effect transistors (MOSFETs) and solid-state photomultipliers (SSPMs), etc., have been reported to estimate the absorbed dose of radiation with sensitivity varying by several orders of magnitude from μGy to MGy. In addition, the mitigation of soft errors in integrated circuits essentially requires detection of charged particle induced transients and digital bit-flips in storage elements. Depending on the particle energies, flux and the application requirements, several sensing solutions such as diodes, static random access memory (SRAM) and NAND flash, etc., are reported in the literature. This article goes through the evolution of radiation dosimeters and particle detectors implemented using semiconductor technologies and summarises the features with emphasis on their underlying principles and applications. In addition, this article performs a comparison of the different methodologies while mentioning their advantages and limitations.

21 February 2021
Verified
Conference Paper
Closed access
AKArijit Karmakar
Arijit Karmakar
VSValentijn De Smedt
Valentijn De Smedt
Paul LerouxPaul Leroux
Paul Leroux
This work proposes a pseudo-differential time-domain integrator using half-delay time-domain registers and adders relying on charge-based time-domain circuits. It is implemented using a 65-nm CMOS Technology and performs first order integration of time-domain information within the range of [4 ns, -4 ns] across temperature -40° C to 80° C. It consumes 740 µW with a supply voltage of 1.2 V at a 100 MHz clock frequency. A delay-locked-loop (DLL) based foreground calibration is used to compensate for process and temperature variations.

19 February 2025 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
KBKieran De Bruyn
Kieran De Bruyn
AKArijit Karmakar
Arijit Karmakar
WGWarre Geeroms
Warre Geeroms
MVMichael Vanhoecke
Michael Vanhoecke
LBLaurens Bogaert
Laurens Bogaert
JBJohan Bauwelinck
Johan Bauwelinck
This article presents a radiation-hardened-by-process 56 Gbps 56 Gbps electro-absorption modulator driver designed in a 130nm SiGe BiCMOS technology for application in optical intra-satellite links. Details of the driver architecture are provided, along with the electrical and optical measurement setups used to evaluate its performance. To assess the vulnerability of the driver against radiation exposure in the space environment, samples were irradiated with X-rays up to a total accumulated dose of 1.2 Mrad(Si), simulating the effects of Total Ionizing Dose (TID) in orbit. Furthermore, heavy-ion experiments corroborated the driver’s resilience to Single Event Transients (SETs) across a range of linear energy transfers (LETs) from 20 to 65.2MeV cm2/mg, with a particle fluence of 1.2 × 107 cm−2. No Single Event Latchup (SEL) was observed in the irradiated samples during the heavy-ion exposure.

27 April 2022 in Electronics
Verified
Journal Article
Open access
PDF file
AKArijit Karmakar
Arijit Karmakar
Valentijn De SmedtValentijn De Smedt
Valentijn De Smedt
Paul LerouxPaul Leroux
Paul Leroux
This article presents a comprehensive assessment of the ionizing radiation induced effects on the performance of quadrature phase LC-tank based voltage-controlled-oscillators (VCOs). Two different quadrature VCOs (QVCOs) that are capable of generating frequencies in the range of 2.5 GHz to 2.9 GHz are implemented in a commercial 65 nm bulk CMOS technology to target for harsh radiation environments like space applications and high-energy physics (HEP) experiments. Each of the QVCOs consumes 13 mW power from a 1.2 V supply. The architectures are based on the popular implementation of two different types of QVCOs: parallel-coupled QVCO (PQVCO) and super-harmonic coupled QVCO (SQVCO). The various performance metrics (oscillation frequency, quadrature phase, phase noise, frequency tuning range, and power consumption) of the two different QVCOs are evaluated with respect to a Total ionizing Dose (TID) up to a level of approximately 100 Mrad (SiO2) through X-ray irradiation. During irradiation, the electrical characterization of the samples of the prototype are performed under biased condition at room temperature. Before irradiation, the QVCOs (PQVCO and SQVCO) achieve phase noise equal to −115 dBc/Hz and −119 dBc/Hz at 1 MHz offset, resulting in figure-of-merit (FoM) of −172.2 dBc/Hz and −176.4 dBc/Hz respectively. The test-setup of the TID experiment is discussed and the results obtained are statistically analyzed in this article to perform a comparative study of the performance of the two different QVCOs and evaluate the effectiveness of the radiation hardened by design techniques (RHBDs) employed in the implementations. Post-irradiation, the overall variations of the frequencies of the oscillators are less than 1% and the change in tuning range (TR) is less than 5% as observed from the tested samples.

1 May 2021
Verified
Conference Paper
Closed access
AKArijit Karmakar
Arijit Karmakar
VSValentijn De Smedt
Valentijn De Smedt
Paul LerouxPaul Leroux
Paul Leroux
This work presents a capacitance-to-digital converter (CDC) fully designed using time-domain circuits following the principle of a dual quantization based first-order ΔΣ modulator. The prototype supports capacitance measurement within the range of 0-3.75 pF and is implemented using a 65-nm CMOS Technology. It consumes 2 mW from a 1.2 V supply while sampling at a 100 MHz clock frequency. The CDC prototype achieves an ENOB of 12.9 bits with an energy efficiency of 0.18 pJ energy per conversion-step.

1 April 2015
Verified
Conference Paper
Closed access
PAProttay M. Adhikari
Prottay M. Adhikari
AKArijit Karmakar
Arijit Karmakar
RDRanjan Das
Ranjan Das
In present days, all the fundamental concepts and techniques of signal processing and control theory is being extended towards fractional order systems. In this paper, we considered a family of fractional order low pass filters. Using the concepts of fractional order calculus, they are approximated uptoa satisfactory level. We then took these approximated transfer functions and realised them using operational amplifiers and passive components(resistors and capacitors). The resistors were further approximated by switched capacitor(SC) arrangements. The switched capacitor based filters are simulated in Or CADp SPICE platform. These results were matched with their corresponding theoretical responses simulated in MATLAB. The broad purpose of this work is to propose a novel technique to design fractional order filters which can be used in discrete time analog signal processing applications or control applications. The goal behind using SC arrangements was to make the integration of both analog and digital functions possible in a single chip.