The use of phase change materials (PCMs) has become an increasingly common way to reduce a building’s energy usage when added to the building envelope. This developing technology has demonstrated improvements in thermal comfort and energy efficiency, making it a viable building energy solution. The current study intends to provide a comprehensive review of the published studies on the utilization of PCMs in various constructions of energy-efficient roofs, walls, and ceilings. The research question holds massive potential to unlock pioneering solutions for maximizing the usefulness of PCMs in reducing cooling demands, especially in challenging high-temperature environments. Several issues with PCMs have been revealed, the most significant of which is their reduced effectiveness during the day due to high summer temperatures, preventing them from crystallizing at night. However, this review investigates how PCMs can delay the peak temperature time, reducing the number of hours during which the indoor temperature exceeds the thermal comfort range. Additionally, the utilization of PCMs can improve the building’s energy efficiency by mitigating the need for cooling systems during peak hours. Thus, selecting the right PCM for high temperatures is both critical and challenging. Insulation density, specific heat, and thermal conductivity all play a role in heat transfer under extreme conditions. This study introduces several quantification techniques and paves the way for future advancements to accommodate practical and technical solutions related to PCM usage in building materials.
Low-emissivity (low-E) window films are designed to improve the thermal comfort and energy performance of buildings. These films can be applied to different glazing systems without having to change the whole window. This makes it possible to apply films to windows in old and historical buildings for which preservation regulations often require that windows should remain unchanged. This research aims to investigate the impacts of low-E window films on the energy performance and thermal comfort of a three-story historical stone building in the cold climate of Sweden using the simulation software “IDA ICE”. On-site measurements were taken to acquire thermal and optical properties of the windows. This research shows that the application of the low-emissivity window film on the outward-facing surface of the inner pane of the double-glazed windows helped to reduce heat loss through the windows in winter and unwanted heat gains in summer by almost 36% and 35%, respectively. This resulted in a 6% reduction in the building’s annual energy consumption for heating purposes and a reduction in the percentage of total occupant hours with thermal dissatisfaction from 14% (without the film) to 11% (with the film). However, the relatively high price of the films and low price of district heating results in a rather long payback period of around 30 years. Thus, the films seem scarcely attractive from a purely economic viewpoint, but may be warranted for energy/environmental and thermal comfort reasons.
The performance of a newly designed corner impinging jet air distribution method with an equilateral triangle cross section was evaluated experimentally and compared to that of two more traditional methods (mixing and displacement ventilation). At nine evenly chosen positions with four standard vertical points, air velocity, turbulence intensity, temperature, and tracer gas decay measurements were conducted for all systems. The results show that the new method behaves as a displacement ventilation system, with high air change effectiveness and stratified flow pattern and temperature field. Both local air change effectiveness and air exchange effectiveness of the corner impinging jet showed high quality and promising results, which is a good indicator of ventilation effectiveness. The results also indicate that there is a possibility to slightly lower the airflow rates for the new air distribution system, while still meeting the requirements for thermal comfort and indoor air quality, thereby reducing fan energy usage. The draught rate was also lower for corner impinging jet compared to the other tested air distribution methods. The findings of this research show that the corner impinging jet method can be used for office ventilation.