Tayeb Allaoui

Tayeb Allaoui

Auto-generated profile, based on publicly available information

Tayeb Allaoui

University of Tiaret

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
SHSamira Heroual
Samira Heroual
BBBelkacem Belabbas
Belkacem Belabbas
YDYasser Diab
Yasser Diab
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
TATayeb Allaoui
Tayeb Allaoui
NBNaima Benabdallah
Naima Benabdallah
This paper focuses on developing power management strategies for hybrid energy storage systems (HESSs) combining batteries and supercapacitors (SCs) with photovoltaic (PV) systems. The proposed control scheme is based on proportional‐integral (PI) controllers optimized with particle swarm optimization (PSO) and duplicate particle swarm optimization (DPSO) algorithms. The aim is to reduce peak current and the energy management system’s response time while enhancing the system’s stability during the charging and discharging of the HSS under various operating conditions. A comparative study with other tuning methods is presented to demonstrate the effectiveness of the proposed DPSO algorithm in particle duplication, population diversity, and the convergence speed toward the global optimum, enhancing the overall system’s performance. The results demonstrate the feasibility and robustness of the PI − DPSO in providing quick and accurate responses even under variable load, variable solar irradiations, and variable temperature, thus enhancing the dynamic response of the SC and reducing battery stress, resulting in a longer lifespan for the HESS.

6 November 2022 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
ABABDELKADER AZZEDDINE BENGHARBI
ABDELKADER AZZEDDINE BENGHARBI
SLsouad laribi
souad laribi
TAT. Allaoui
T. Allaoui
AMA. Mimouni
A. Mimouni
Introduction. This research work focuses on the design and experimental validation of fault detection techniques in grid-connected solar photovoltaic system operating under Maximum Power Point Tracking mode and subjected to various operating conditions. Purpose. Six fault scenarios are considered in this study including partial shading, open circuit in the photovoltaic array, complete failure of one of the six IGBTs of the inverter and some parametric faults that may appear in controller of the boost converter. Methods. The fault detection technique developed in this work is based on artificial neural networks and uses discrete wavelet transform to extract the features for the identification of the underlying faults. By applying discrete wavelet transform, the time domain inverter output current is decomposed into different frequency bands, and then the root mean square values at each frequency band are used to train the neural network. Results. The proposed fault diagnosis method has been extensively tested on the above faults scenarios and proved to be very effective and extremely accurate under large variations in the irradiance and temperature. Practical significance. The results obtained in the binary numerical system allow it to be used as a machine code and the simulation results has been validated by MATLAB / Simulink software.

6 September 2022 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
MAMIMOUNA ABID
MIMOUNA ABID
SLsouad laribi
souad laribi
MLM. Larbi
M. Larbi
TAT. Allaoui
T. Allaoui
Introduction. To attain high efficiency and reliability in the field of clean energy conversion, power electronics play a significant role in a wide range of applications. More effort is being made to increase the dependability of power electronics systems. Purpose. In order to avoid any undesirable effects or disturbances that negatively affect the continuity of service in the field of energy production, this research provides a fault detection technique for insulated-gate bipolar transistor open-circuit faults in a three-level diode-clamped inverter of a wind energy conversion system predicated on a doubly-fed induction generator. The novelty of the suggested work ensures the regulation of power exchanged between the system and the grid without faults, advanced intelligence approaches based on a multilayer artificial neural network are used to discover and locate this type of defect; the database is based on the module and phase angle of three-phase stator currents of induction generators. The proposed methods are designed for the detection of one or two open-circuit faults in the power switches of the side converter of a doubly-fed induction generator in a wind energy conversion system. Methods. In the proposed detection method, only the three-phase stator current module and phase angle are used to identify the faulty switch. The primary goal of this fault diagnosis system is to effectively detect and locate failures in one or even more neutral point clamped inverter switches. Practical value. The performance of the controllers is evaluated under different operating conditions of the power system, and the reliability, feasibility, and effectiveness of the proposed fault detection have been verified under various open-switch fault conditions. The diagnostic approach is also robust to transient conditions posed by changes in load and speed. The proposed diagnostic technique's performance and effectiveness are both proven by simulation in the SimPower /Simulink® MATLAB environment.

21 October 2023 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
YMY. A. Mabrouk
Y. A. Mabrouk
MBMokhtari Bachir
Mokhtari Bachir
TAT. Allaoui
T. Allaoui
Introduction. The best way to control the torque of an induction motor is conventional direct torque control (DTC); this control method is the most used approach in the industrial sector due to its many advantages. Its main advantages are its simplicity and its exclusive dependence on the stator resistance of the induction motor. However, the use of hysteresis comparators reduces its effectiveness, causing more torque ripple. Additionally, this results in variable operating frequency and limited frequency sampling, resulting in pseudo-random overshoot of the hysteresis band. Purpose. For these reasons, this article presents a new study aimed at confirming its shortcomings and improving the effectiveness of the control. Novelty. We propose to use fuzzy logic methods to estimate the two components of the stator flux. Methods. In traditional DTC the flux components are estimated from an equation relating the stator resistance to the stator voltage and current. In the proposed method, only stator currents and voltages are used for this evaluation, which eliminates the dependence of DTC on stator resistance. The aim of this proposal is to make DTC robust to parametric changes. Results. General harmonic distortions, rotational speed of the induction motor, electromagnetic moment, magnetic flux and stator currents are analyzed. Practical value. With this proposed technique, validated in Simulink/MATLAB, several improvements in motor behavior and control are endorsed: torque fluctuations are reduced, overshoot is completely eliminated, and total harmonic distortion is significantly reduced by 48.31 % for stator currents. This study also confirmed the robustness of DTC to changes in stator resistance. Вступ. Найкращим способом управління крутним моментом асинхронного двигуна є традиційне пряме управління крутним моментом (DTC); цей метод управління є найбільш використовуваним у промисловому секторі через його численні переваги. Його основними перевагами є простота та виключна залежність від опору статора асинхронного двигуна. Однак використання гістерезисних компараторів знижує його ефективність, викликаючи велику пульсацію крутного моменту. Крім того, це призводить до зміни робочої частоти та обмеження вибірки частоти, що призводить до псевдовипадкового виходу за межі смуги гістерезису. Мета. З цих причин у цій статті представлено нове дослідження, спрямоване на підтвердження його недоліків та підвищення ефективності контролю. Новизна. Ми пропонуємо використовувати методи нечіткої логіки з метою оцінки двох компонентів потоку статора. Методи. У традиційному DTC компоненти потоку оцінюються за рівнянням, що зв'язує опір статора з напругою та струмом статора. У запропонованому методі цієї оцінки використовуються лише струми і напруги статора, що виключає залежність DTC від опору статора. Мета цієї пропозиції – зробити DTC стійким до параметричних змін. Результати. Аналізуються загальні гармонічні спотворення, швидкість обертання асинхронного двигуна, електромагнітний момент, магнітний потік та струми статору. Практична цінність. За допомогою цього запропонованого методу, перевіреного в Simulink/MATLAB, підтверджено кілька покращень у поведінці та управління двигуном: коливання крутного моменту зменшуються, перерегулювання повністю усувається, а загальні гармонічні спотворення значно зменшуються на 48,31% для струмів статора. Це дослідження підтвердило стійкість DTC до змін опору статора.

4 January 2023 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
AMA. Mimouni
A. Mimouni
SLsouad laribi
souad laribi
SMSEBAA Morsli
SEBAA Morsli
TAT. Allaoui
T. Allaoui
ABABDELKADER AZZEDDINE BENGHARBI
ABDELKADER AZZEDDINE BENGHARBI
Introduction. The widespread use of photovoltaic systems in various applications has spotlighted the pressing requirement for reliability, efficiency and continuity of service. The main impediment to a more effective implementation has been the reliability of the power converters. Indeed, the presence of faults in power converters that can cause malfunctions in the photovoltaic system, which can reduce its performance. Novelty. This paper presents a technique for diagnosing open circuit failures in the switches (IGBTs) of power converters (DC-DC converters and three-phase inverters) in a grid-connected photovoltaic system. Purpose. To ensure supply continuity, a fault-diagnosis process is required throughout all phases of energy production, transfer, and conversion. Methods. The diagnostic approach is based on artificial neural networks and the extraction of features corresponding to the open circuit fault of the IGBT switch. This approach is based on the Clarke transformation of the three-phase currents of the inverter output as well as the calculation of the average value of these currents to determine the exact angle of the open circuit fault. Results. This method is able to effectively identify and localize single or multiple open circuit faults of the DC-DC converter IGBT switch or the three-phase inverter IGBT switches.

31 January 2025 in International Journal of Robotics and Control Systems
Verified
Journal Article
Open access
PDF file
SHSamira Heroual
Samira Heroual
BBBelkacem Belabbas
Belkacem Belabbas
IEI. M. Elzein
I. M. Elzein
YDYasser DIAB
Yasser DIAB
AMAlfian Ma'arif
Alfian Ma'arif
NBNaima Benabdallah
Naima Benabdallah
One of the main issues with grid-connected distributed energy systems, including photovoltaic (PV) systems, is the DC bus voltage's instability during load fluctuations and power line short circuits. This paper attempts to address this problem and proposes to use superconducting magnetic energy storage (SMES) to stabilize the voltage of the DC link and improve the power quality and transient stability of the power system. The investigated configuration components are PV cells, boost converter, chopper, SMES, three level inverter (NPC), filter, grid, and load. MATLAB / Sim Power System is used to test the performance of a SMES in order to ensure the balance of the DC bus voltage of a PV system connected to the grid. Several scenarios were considered to show the performance and benefits of combining a SMES with the PV system. The outcomes of the examined scenarios (fault and load change) demonstrate the precision of the employed control systems, maintaining the DC voltage at acceptable levels (≈500 V), enhances the structure stability, and improving power quality (GPV THD = 4.34). Finally, it can be concluded that the proposed configuration will help in achieving high penetration scenarios of PV systems.