1 May 2022 in Review of Scientific Instruments
Pulsed power technology is gradually forming a development trend of civil-military integration, which puts forward more requirements for pulsed power generators. This paper takes magnetic switches (MSs) as the starting point and reviews recent advancements in pulse generators based on MSs. First, the working mechanism of the MS “rapid inductance drop after magnetic core saturation” is analyzed. Second, the basic uses of MSs are introduced with specific examples, namely, magnetic compression unit, saturated pulse transformer, and magnetic delay switches. Then, the typical topologies of pulse generators based on MSs are discussed, including transmission line, Marx, Fitch, linear transformer driver, and semiconductor opening switch pumping circuits. These circuits’ technical characteristics and parameter levels are highlighted. Finally, the existing problems and future development trends of MS-based solid-state pulse generators are discussed.
1 July 2019 in Review of Scientific Instruments
In this paper, a torsional thrust balance with an asymmetrical arm is designed and tested which is effective for the microthruster performance evaluation in the vacuum facilities with limited space. An optimization design method for the key parameters of the thrust balance has been developed. By utilizing the asymmetrical arm, a great resolution can be obtained with a restrained arm length. A novel printed circuit board electrostatic comb has been applied to the thrust balance calibration. Experimental results show that the comb is capable of producing steady force in the range of about 30 μN–3300 μN and an impulse bit of 7 µNs–777 µNs which can be further extended to nano-Newton second range with a shorter pulse width and a lower voltage. The calibration results show that the thrust balance has a great repeatability and reliability. The total uncertainty of the thrust stand is estimated to be 3.33% in the 1 µNs range.
1 September 2022 in Review of Scientific Instruments
Electrical wire explosions have many applications in scientific research and industry. Optical diagnosis is a powerful method to clarify the evolutionary process of such explosions. In this paper, an experimental platform was established to diagnose the optical radiation of electrical wire explosions. A low-jitter trigatron switch and its trigger generator were designed to ensure accurate synchronization. The spatial–temporal evolution process and the self-emission spectrum of electrical explosion plasmas from different wires (copper and tantalum) were obtained and analyzed. The optical diagnosis results indicated that the electrical explosion of copper wire was mainly characterized by the inhomogeneity of partial ionization and the rapid expansion of the discharge channel. The spectrum in the early discharge stage of the copper wire electrical explosion was a continuum, and most of the self-radiation spectral lines belonged to Cu I or Cu II. At the later stage of the plasma dissipation process, the continuous spectrum gradually transformed into a line spectrum. The development of the tantalum wire discharge channel was relatively uniform, and the plasma was mainly established in the gas–liquid mixed phase channel of the tantalum wire. The self-emission spectrum of the tantalum wire was always continuous, and the absorption process of line spectrum radiation was distinct.
1 September 2024 in Review of Scientific Instruments
Plasma ignition and combustion enhancement is a promising technology in applications of engines, industrial burners, pollutant emissions controls, etc. A new repetitive electrothermal plasma jet ignition system based on ablated capillary discharge under atmospheric pressure is presented in this paper. It consists of a capillary discharge module, a pulse current circuit, a pulse voltage circuit, a current release unit, an LC series resonant circuit, and a control system. The effects of the energy storage capacitor’s voltage and resistance in the current release unit on the electrical parameters are investigated. Increasing the capacitor voltage helps to shorten the discharge delay and increase the energy deposition efficiency in the main discharge process. The increase of the resistance in the current release unit leads to a longer discharge delay and higher energy deposition efficiency in the main discharge process. Balanced parameters between the delay of discharge in 66 µs and the energy deposition efficiency in 84% are achieved through optimization, with a peak radiative heat flux of 23 MW m−2 and a maximum jet length of 17 cm. Repetitive capillary discharge at 20 Hz under atmospheric pressure is achieved with the dispersion of energy storage capacitor charging voltage and energy deposition efficiency of 0.3% and 9.6%, respectively. Simplified circuit topology and control logic contribute to the miniaturization of the ignition system.
1 October 2025 in Review of Scientific Instruments
With the increasing incidence of electrical overstress (EOS) failures in electronic devices, investigating the behavioral characteristics of integrated circuits under long-pulse-width and DC electrical stress is crucial for enhancing product reliability. Conventional surge stress tests are primarily pass/fail-oriented and lack dedicated research-grade methodologies and instruments for analyzing device behavior under prolonged pulse width and high current, hindering the establishment of a quantitative basis for top-down EOS protection design. In this study, we present an EOS test system with multiple adjustable parameters to simulate diverse EOS conditions. Under a 50 Ω matched load, the EOS simulator achieves a minimum rise time of 8 ns (adjustable to longer durations), a voltage amplitude of 50 V, and a square-wave pulse width tunable from 5 µs to DC. The maximum output current amplitude varies with pulse width, reaching up to 540 A under short-circuit conditions with a 300 µs pulse width. The system is utilized to perform experiments on a transient voltage suppressor, revealing previously unobserved triggering behavior under long-pulse-width stress and elucidating its failure process and the failure threshold curve. Furthermore, an efficient test methodology for such conditions is proposed. This system supports comprehensive device characterization, transient behavior analysis, behavioral modeling, and systematic EOS protection design.