21 March 2024 in Scientific Reports
Positioning the positive pressure ventilator in front of the door opening affects the effectiveness of the rescue operation carried out during a fire. An important factor determining the effectiveness of the positive pressure ventilator is also the layout of the rooms within the gas exchange path and the obstacles present there. The purpose of this article is to assess the feasibility of using analyses such as large eddy simulation (LES) to verify the efficiency of mobile fans under simulation conditions, without the need for time-consuming experimentation (also for complex room volumes of buildings). The article presents a comparative analysis to assess the degree of convergence of flow parameters obtained during an experiment (in a multi-story building) and computational fluid dynamics (CFD) simulations. For volumetric flow rate, convergence was achieved at levels ranging from 0.4% (for 5 m) to 11.5% (1 m), and for pressure values, the differences achieved ranged from 0.6% (5 m) to 30.1% (4 m). This paper demonstrates that the LES model can be used to perform CFD simulations in the area of assessing the performance of a positive pressure ventilator. The article also describes a test methodology for determining the flow parameters of an air stream, which can be used to perform numerical simulations.
15 August 2019 in International Journal of Numerical Methods for Heat & Fluid Flow
Purpose: The aim of this study is to identify key factors limiting efficiency of pumped heat energy storage systems and determine some general features of transient behavior of solid state, sensible heat storages. Moreover, it aimed at establishing a feasible approach to transient conjugate heat transfer (CHT) analyses for such applications. Design/methodology/approach: A zero-dimensional analytical model is used to determine the system efficiency sensitivity to efficiency of its components. Analysis of argon gas flow in an exemplary configuration of layered bed thermal energy storage is presented. The analysis incorporates a unsteady reynolds averaged navier stokes model with conjugate heat transfer between gas and solid storage core. Findings: It is established that exergetic efficiency of the heat storage is one of the key factors for the system’s overall performance. Three full cycles of storage charging and discharging having 17 h physical time in total are simulated, with calculation of exergetic efficiency for each of the cycles. From standpoint of the system efficiency, it is concluded that the presented heat storage kind has limited exergetic efficiency because of severe temperature drop at the solid–fluid interface in comparison to granular kind of heat storage devices. From the methodological standpoint, it is concluded that calculating the exergetic efficiency of the heat storage by direct computational fluid dynamics (CFD) analysis requires significant amount of walltime and computational resources. Originality/value: The paper presents unconventional approach to using standard CFD tools by exploiting numerical diffusion to numerically suppress high-frequency solution oscillations. This strategy grants that the analysis, otherwise requiring impractically long computation walltime, is completed within a practical time.
1 February 2025 in Physics of Fluids
Improved turbulence models are necessary for achieving more accurate solutions in Reynolds-averaged Navier–Stokes (RANS) simulations. RANS is widely used in various engineering applications, and enhancing its accuracy is crucial for geometry design and control applications. With the increasing availability of high-fidelity datasets, machine learning (ML) techniques offer the opportunity for data-driven inference of RANS equation closure terms. By Pope's theoretical analysis, ML turbulence closure models for RANS simulations are often used alongside physics-informed preprocessing of equivariant tensor basis. In this work, we replace this established approach by designing an equivariant turbulence model with Euclidean Neural Networks (e3nn). We demonstrate that Pope's tensor basis is a special case of our model. We test the model on the periodic hills flow case dataset. Our approach significantly improves the prediction of anisotropic components of Reynolds stresses, leading to more accurate modeling of the flow field when integrated into RANS through a single injection.
27 November 2018 in MATEC Web of Conferences
An analysis of argon gas flow in exemplary configuration of layered bed thermal energy storage is presented. The analysis incorporates URANS model with conjugate heat transfer between gas and solid storage core. The aim of this analysis was to identify key factors limiting exergy efficiency of this storage type and determine some details about storage transient behaviour. Three full cycles of storage loading and unloading having 17 hours physical time in total are simulated, with calculation of exergetic efficiency for each of the cycles. Conclusions regarding this storage type feasibility for indirect power storage in pumped heat systems are made.