Jan Gajewski

Mr. Jan Gajewski

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2021 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
KDKamil Dulski
Kamil Dulski
NCNeha Chug
Neha Chug
CCCatalina Curceanu
Catalina Curceanu
ECEryk Czerwiński
Eryk Czerwiński
WWWojciech Wiślicki
Wojciech Wiślicki
Positronium created in a human body during PET scans hallmarks neoplastic tissues.

1 February 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
CGCarlos Granja
Carlos Granja
COCristina Oancea
Cristina Oancea
JJJan Jakubek
Jan Jakubek
LMLukas Marek
Lukas Marek
EBEric Benton
Eric Benton
PKPavel Krist
Pavel Krist

8 May 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PSPaulina Stasica
Paulina Stasica
HNHanh Nguyen
Hanh Nguyen
CGCarlos Granja
Carlos Granja
RKRenata Kopec
Renata Kopec
LMLukas Marek
Lukas Marek
JGJan Gajewski
Jan Gajewski
Objective. Protons have advantageous dose distributions and are increasingly used in cancer therapy. At the depth of the Bragg peak range, protons produce a mixed radiation field consisting of low- and high-linear energy transfer (LET) components, the latter of which is characterized by an increased ionization density on the microscopic scale associated with increased biological effectiveness. Prediction of the yield and LET of primary and secondary charged particles at a certain depth in the patient is performed by Monte Carlo simulations but is difficult to verify experimentally. Approach. Here, the results of measurements performed with Timepix detector in the mixed radiation field produced by a therapeutic proton beam in water are presented and compared to Monte Carlo simulations. The unique capability of the detector to perform high-resolution single particle tracking and identification enhanced by artificial intelligence allowed to resolve the particle type and measure the deposited energy of each particle comprising the mixed radiation field. Based on the collected data, biologically important physics parameters, the LET of single protons and dose-averaged LET, were computed. Main results. An accuracy over 95% was achieved for proton recognition with a developed neural network model. For recognized protons, the measured LET spectra generally agree with the results of Monte Carlo simulations. The mean difference between dose-averaged LET values obtained from measurements and simulations is 17%. We observed a broad spectrum of LET values ranging from a fraction of keV μm−1 to about 10 keV μm−1 for most of the measurements performed in the mixed radiation fields. Significance. It has been demonstrated that the introduced measurement method provides experimental data for validation of LETD or LET spectra in any treatment planning system. The simplicity and accessibility of the presented methodology make it easy to be translated into a clinical routine in any proton therapy facility.

1 October 2021 in Radiotherapy and Oncology
Verified
Journal Article
Open access
MGMagdalena Garbacz
Magdalena Garbacz
FCFrancesco Giuseppe Cordoni
Francesco Giuseppe Cordoni
Marco DuranteMarco Durante
Marco Durante
JGJan Gajewski
Jan Gajewski
KKKamil Kisielewicz
Kamil Kisielewicz
ARAntoni Rucinski
Antoni Rucinski
We investigated the relationship between RBE-weighted dose (DRBE) calculated with constant (cRBE) and variable RBE (vRBE), dose-averaged linear energy transfer (LETd) and the risk of radiographic changes in skull base patients treated with protons. Clinical treatment plans of 45 patients were recalculated with Monte Carlo tool FRED. Radiographic changes (i.e. edema and/or necrosis) were identified by MRI. Dosimetric parameters for cRBE and vRBE were computed. Biological margin extension and voxel-based analysis were employed looking for association of DRBE(vRBE) and LETd with brain edema and/or necrosis. When using vRBE, Dmax in the brain was above the highest dose limits for 38% of patients, while such limit was never exceeded assuming cRBE. Similar values of Dmax were observed in necrotic regions, brain and temporal lobes. Most of the brain necrosis was in proximity to the PTV. The voxel-based analysis did not show evidence of an association with high LETd values. When looking at standard dosimetric parameters, the higher dose associated with vRBE seems to be responsible for an enhanced risk of radiographic changes. However, as revealed by a voxel-based analysis, the large inter-patient variability hinders the identification of a clear effect for high LETd.

1 August 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
KDKamil Dulski
Kamil Dulski
SBSteven D. Bass
Steven D. Bass
JCJ. Chhokar
J. Chhokar
NCN. Chug
N. Chug
CCCatalina Curceanu
Catalina Curceanu
PMPawel Moskal
Pawel Moskal

11 November 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
DBDamian Borys
Damian Borys
JBJakub Baran
Jakub Baran
KBKarol Brzeziński
Karol Brzeziński
JGJan Gajewski
Jan Gajewski
NCNeha Chug
Neha Chug
ARAntoni Rucinski
Antoni Rucinski
Objective. This paper reports on the implementation and shows examples of the use of the ProTheRaMon framework for simulating the delivery of proton therapy treatment plans and range monitoring using positron emission tomography (PET). ProTheRaMon offers complete processing of proton therapy treatment plans, patient CT geometries, and intra-treatment PET imaging, taking into account therapy and imaging coordinate systems and activity decay during the PET imaging protocol specific to a given proton therapy facility. We present the ProTheRaMon framework and illustrate its potential use case and data processing steps for a patient treated at the Cyclotron Centre Bronowice (CCB) proton therapy center in Krakow, Poland. Approach. The ProTheRaMon framework is based on GATE Monte Carlo software, the CASToR reconstruction package and in-house developed Python and bash scripts. The framework consists of five separated simulation and data processing steps, that can be further optimized according to the user’s needs and specific settings of a given proton therapy facility and PET scanner design. Main results. ProTheRaMon is presented using example data from a patient treated at CCB and the J-PET scanner to demonstrate the application of the framework for proton therapy range monitoring. The output of each simulation and data processing stage is described and visualized. Significance. We demonstrate that the ProTheRaMon simulation platform is a high-performance tool, capable of running on a computational cluster and suitable for multi-parameter studies, with databases consisting of large number of patients, as well as different PET scanner geometries and settings for range monitoring in a clinical environment. Due to its modular structure, the ProTheRaMon framework can be adjusted for different proton therapy centers and/or different PET detector geometries. It is available to the community via github (Borys et al 2022).