20 January 2021 in IEEE Transactions on Nuclear Science
Point or distributed optical fiber (OF)-based dosimeters can exploit the observed linear dependence of the radiation-induced attenuation (RIA) at 1550 nm in phosphosilicate OFs to monitor the total ionizing dose (TID). The temperature dependence of the radiation sensitivity coefficients at 1550 nm (expressed in dB km -1 Gy -1 ) of three phosphorus-doped single-mode OFs has been investigated between -80 °C and 300 °C for TID ranging from 1 Gy to 1 kGy(SiO 2 ). Our measurements reveal the same temperature dependence of the calibration factor for the three fibers at the higher temperatures (>120 °C) where the P1 defects, at the origin of the IR-RIA, are metastable. However, the uncertainties on the TID measurements through the fiber-based dosimeter remain within the 15% for temperatures ranging from -80 °C to 120 °C for the three tested fibers. The independence of the RIA and then of the dose measurements from the dose rate is also maintained in this temperature range.
6 November 2012 in Journal of Non-Crystalline Solids
20 March 2020 in IEEE Transactions on Nuclear Science
We analyzed the simultaneous response to radiation and temperature exposure of radiation-sensitive optical fibers doped with Aluminum, Phosphorus and/or Germanium in the framework of the CERTYF (Combined Effects of Radiations, Temperature and hYdrogen on silica-based optical Fibers) project, whose aim is to build a predictive model based on intrinsic and extrinsic optical parameters.
24 March 2021 in IEEE Transactions on Nuclear Science
We investigated the radiation-induced attenuation (RIA) at 1550 nm under X-rays in two single-mode germanosilicate optical fibers (OFs): the Corning SMF-28e + and a homemade fiber manufactured by the Université Côte d'Azur in the framework of the CERTYF project. The RIA dependence on the injected power level of the probing signal is studied in order to analyze the photobleaching phenomenon at high doses [>100 kGy(SiO 2 )]. The Corning SMF-28e + revealed no RIA variation with the signal power (microwatts-milliwatts range), proving to be a good candidate for distributed OF sensor (DOFS) applications, while the CERTYF OF showed a clear photobleaching effect. A fitting routine based on the second-order growth kinetics model of Griscom has been performed, which has shown good consistency with the experimental results and offered a quantitative evaluation of the photobleaching effect on the CERTYF OF.
26 April 2021 in IEEE Transactions on Instrumentation and Measurement
This article reports on the first demonstration of in situ , real-time dosimetry realized with an enhanced backscattering optical fiber, and a high-resolution optical backscattering reflectometry measurement. This work is devised to overcome the current problems in monitoring radiotherapy treatments, in particular, the difficult evaluation of not only the actual X-ray dose that is accumulated on the target volume but also the distribution profile of the ionizing radiation beam. Overall, the research aims at developing a dose sensor with the most demanding features of small form factor, spatial profiling, and remote interrogation. The experiments have been conducted by evaluating the spatial profile of radiation-induced spectral shift of the Rayleigh backscattering along an optical fiber exposed to X-rays. The sensing element is a section of specialty optical fiber whose Rayleigh backscattering signature changes under ionizing radiation. The specialty fiber is designed to exhibit an enhanced backscattering, in order to overcome the poor sensitivity to radiation of standard optical fibers that are normally, used in telecommunications. The enhanced sensitivity is achieved by doping the core with either aluminum or magnesium nanoparticles, and two different fibers have been fabricated and tested. The experimental results show the capability of real time detection of the radiation profile from high-dose rates (700 Gy/min) to low-dose rates (2 Gy/min). Moreover, different sensing mechanisms and responses to high- and low-dose rates are evidenced. A comparison with a quasi-distributed sensing system based on an array of fiber Bragg gratings (FBGs) is discussed, highlighting the superior performance of the backscattering approach in terms of sensitivity and spatial resolution, whereas the array of FBGs exhibits an advantage in terms of sampling speed.
31 May 2000 in Diamond and Related Materials