2 September 2021 in IEEE Transactions on Electromagnetic Compatibility
In 2015, the energy measurement of some static electricity meters was found to be sensitive to specific conducted electromagnetic disturbances with very fast current changes caused by highly nonlinear loads, leading to meter errors up to several hundred percent. This article describes new results on the electromagnetic compatibility (EMC) of 16 different meters from all over Europe when exposed to real-world disturbance signals. Those test signals were obtained from household appliances and onsite measurements at metered supply points all over Europe. The results show that also the interference signals recorded onsite can cause measurement errors as large as several hundred percent, even for meters that pass the present EMC standards. This unambiguously demonstrates that the present immunity testing standards do not cover the most disturbing conducted interference occurring in present daily-life situations due to the increased use of nonlinear electronics. Furthermore, to enable the adoption of potential new test waveforms in future standards for electricity meter testing, artificial test waveforms were constructed based on real-world waveforms using a piece-wise linear model. These artificial test waveforms were demonstrated to cause meter errors similar to those caused by the original real-life waveforms they are representing, showing that they are suitable candidates for use in improved standardization of electricity meter testing.
9 April 2021 in IEEE Transactions on Electromagnetic Compatibility
This article presents a time-domain waveform model developed to characterize pulsed, nonlinear, current waveforms resulting in electromagnetic interference on static energy meters. The waveform model is calculated by fitting the sampled waveform data into a linear piece-wise function through a process that involves applying algorithms of pulse extraction, change-point detection, and redundancy elimination. The model is applied to data from laboratory experiments that have indicated critical current waveforms resulting in electromagnetic interference problems with static meters. Afterwards, the parameters of the modeled waveforms are calculated in order to correlate them to metering errors. The most relevant parameters that are correlated to significant errors are the maximum slope, crest factor, pulse duration, and charge. The waveform model provides an accurate description of the complex nonlinear waveforms through simplified analytical expressions that reproduce the significant features of the interfering waveforms. This waveform modeling approach could be used to standardize the artificial test signals that are representative of realistic devices and scenarios.
26 September 2022 in IEEE Transactions on Electromagnetic Compatibility
Static energy meters installed in households, used for billing purposes of the energy consumption, have shown errors due to conducted electromagnetic interference coming from appliances in household situations. This resulted in over- and underestimations of the energy bill, and even in a perceived energy generation. The currents causing interference are known to be nonlinear pulsed currents with fast slopes. This article shows that clipping of the amplifier, following the Rogowski coil, which is used as the current sensing element, results in distorted energy measurements. Due to the pulsed nature of the current, the output of the Rogowski coil exceeds the maximum input voltage of the amplifier, resulting in clipping at the output of the amplifier. This clipped signal is then integrated in the digital chain, resulting in an offset in the perceived current. Hence, causing a higher or lower energy calculation, depending on the phase firing angle and the fastest edge of the pulse. It is found that parameters, such as the slew rate, rise and fall times, and firing angle, are correlated to the interference on static energy meters.
18 September 2020 in IEEE Transactions on Electromagnetic Compatibility
Measurement bandwidth of energy measurements are increasing to incorporate all the harmonics created by nonlinear loads and distributed generators making the measurement electronics complex and sensitive to electromagnetic interference. This article proposes to change the accuracy paradigm by focusing on fundamental active power and lower harmonics for energy metering, simplifying the electronics and making them robust against electromagnetic interference. Using the orthogonality of power flow via Parseval’s theorem, a theoretical analysis, simulations, and measurements on power calculations using the fundamental active power are presented. It is shown that a perfect power measurement is achieved with a pure 50 Hz supply voltage, regardless of the nonlinear current. Even with the highest allowed harmonic distortion of the voltage and the current as listed in the international standards EN 50160 and IEC 61000-3-2, more than 97.5% of the active power is contained in the fundamental active power. Negligible active power is contained in the higher frequency components. This error margin falls within limits for electricity meters. Filtering the current with a basic low-pass filter can prevent the erroneous measurements that have appeared with static energy meters. In other words, it has been proven that negligible energy flows in the higher frequency components.
12 July 2021 in IEEE Transactions on Electromagnetic Compatibility
Static energy meters have shown errors beyond the standards due to conducted electromagnetic interference of pulsed currents. This was observed in several case studies and confirmed by laboratory experiments, which showed errors up to 2675%. The extent of this interference case is unknown, because there is limited information about the waveforms occurring in the real on-site scenarios. This article aims to detect critical waveforms in on-site surveyed data that have similar characteristics as the pulses that resulted in metering errors. The time-domain parameters of the laboratory experiments that show static energy meter interference are compared to the on-site waveform data using an interpolation based on an inverse weighting distance function. Using this approach, the waveform characteristics are compared, and an error is estimated. This approach was satisfactorily validated using data from validation experiments that shows a correct estimation of the actual error according to the permissible limits for energy metering for all validation indices. The performed on-site surveys show the existence of nonlinear waveforms. During the survey of three sites for ten days, 19 531 waveforms were captured, of which 14 487 indicate large nonlinearities and 379 are estimated to produce metering errors up to 925%.