In 2015, the energy measurement of some static electricity meters was found to be sensitive to specific conducted electromagnetic disturbances with very fast current changes caused by highly nonlinear loads, leading to meter errors up to several hundred percent. This article describes new results on the electromagnetic compatibility (EMC) of 16 different meters from all over Europe when exposed to real-world disturbance signals. Those test signals were obtained from household appliances and onsite measurements at metered supply points all over Europe. The results show that also the interference signals recorded onsite can cause measurement errors as large as several hundred percent, even for meters that pass the present EMC standards. This unambiguously demonstrates that the present immunity testing standards do not cover the most disturbing conducted interference occurring in present daily-life situations due to the increased use of nonlinear electronics. Furthermore, to enable the adoption of potential new test waveforms in future standards for electricity meter testing, artificial test waveforms were constructed based on real-world waveforms using a piece-wise linear model. These artificial test waveforms were demonstrated to cause meter errors similar to those caused by the original real-life waveforms they are representing, showing that they are suitable candidates for use in improved standardization of electricity meter testing.
The growing use of renewable energy sources and sustainable technologies has increased the attractiveness of low-voltage DC distribution grids. Despite initial research and standardization work, the definition of power quality (PQ) issues and their related compatibility levels in DC grids and the related measurement techniques remain in their infancy. The lack of available measurement results obtained in real-world situations is a major shortcoming. In this paper, the results of a measurement campaign obtained in a configurable bipolar 350 V/700 V DC microgrid in an urban environment are presented. Voltage and current signals were registered continuously at different positions in the microgrid with a sampling rate of 500 kSa/s while changing the configuration of the microgrid; the resulting data were analyzed afterwards, with a focus on DC voltage and current variation, ripple, and spectral analysis. The measurements were taken with custom-designed metrology-sound measurement equipment. The measurement results provide input to the development of DC PQ analysis tools and the standardization of DC PQ measurement methods. Furthermore, the experience obtained will be beneficial for utility companies and regulatory authorities for reliable planning-level and compatibility-level surveys.
Accurate and reliable characterization of current transformer (CT) performance is essential for maintaining grid stability and power quality in modern electrical networks. CT measurements are key to effective monitoring of harmonic distortions, supporting regulatory compliance and ensuring the safe operation of the grid. This paper addresses a method for the characterization of CTs across an extended frequency range from 50 Hz up to 150 kHz, driven by increasing power quality issues introduced by renewable energy installations and non-linear loads. Traditional CT calibration approaches involve measurement setups that offer ppm-level uncertainty but are complex to operate and limited in practical frequency range. To simplify and expand calibration capabilities, a calibration system employing a sampling ammeter (power analyzer) was developed, enabling the direct measurement of CT secondary currents of an unknown CT and a reference CT without any further auxiliary equipment. The resulting expanded magnitude ratio uncertainties for the wideband CT calibration system are 10 ppm () up to 10 kHz and less than 120 ppm from 10 kHz to 150 kHz; these uncertainties do not include the uncertainty of the reference CT. Additionally, the operational conditions and setup design choices, such as instrument warm-up duration, grounding methods, measurement shunt selection, and cable type, were evaluated for their impact on measurement uncertainty and repeatability. The results highlight the significance of minimizing parasitic impedances at higher frequencies and maintaining consistent testing conditions. The developed calibration setup provides a robust foundation for future standardization efforts and practical guidance to characterize CT performance in the increasingly important supraharmonic frequency range.
17 March 2021 in IEEE Transactions on Instrumentation and Measurement
A sampling current ratio measurement system has been developed to calibrate the voltage dependence of ratio error and phase displacement of current transformers (CTs) used for medium-voltage (MV) and high-voltage (HV) applications. The influence of voltage-induced leakage current on the apparent ratio error and phase displacement of the reference circuit was unambiguously demonstrated using a novel measurement method. Measurement results for voltages up to 24 kV show that the observed leakage current is purely capacitive and caused by the shielded cable capacitance of the HV cable used to feed the current. The maximum ratio error and phase displacement were found to be about 100 parts in 10 6 and 100 μrad for the smallest current of 100 A used for these investigations. Since these values scale linearly with the applied voltage and inversely proportional with current, the assumption of negligible voltage dependence used in other reference systems presented in literature is questionable. Using the corrected reference circuit, a commercial class 0.2S MV CT with 2500-A nominal current was calibrated at voltage levels up to 24 kV. The voltage dependence of ratio error and phase displacement for primary currents up to 500 A was demonstrated to be capacitive as well, with a maximum impact on the current ratio of almost 0.9% for a primary current of 100 A (corresponding to 3.6% at 1% of nominal current). This value is beyond the limits of in-force standards, which emphasizes the necessity of implementing voltage dependence testing in those standards.
To assess the reliability of dc energy measurement equipment on-board trains, a setup was developed to characterize current transducers under realistic operating conditions. The operating principle is based on a current ratio measurement technique. The reference sensor is a high-precision zero-flux current transducer in combination with a broadband high-precision current shunt. The influence of ac distortion on this reference sensor was found to be within a few parts in 106 using an initial version of the setup, in which ac distortion was applied through a separate winding. A revised version of the setup employs a programmable electronic load to apply dynamic currents up to 600 A. The setup was used to characterize a 100 μohm high-current shunt resistor. The effect of dissipative heating on the dc transresistance error was around 0.03 %, with a settling time of about half an hour. The short-term intrinsic current dependence was also around 0.03 %. The effect of ac distortion was within a few parts in 106. The intrinsic current dependence and the onset of the heating effect were also observed when exposing the sensor to a dynamic current profile that was recorded during a trip between two successive underground train stations on Metro de Madrid. These results demonstrate that the setup described in this paper is very effective for characterizing dc current sensors for practical railway applications. Future work will concentrate on even more demanding current signals, such as chopped signals, and on other types of sensors and measurement systems.
This paper investigates the possibility of using simplified test methods for the characterization of IT frequency response in the supraharmonic range. Unlike the traditional reference methods, the simplified method relies on generating low-voltage and low-current signals, which are easier to implement in testing and manufacturers' laboratories. This method has been developed as a valid and rigorous alternative to the reference method, with results obtained from the laboratories of different National Metrology Institutes (NMIs). An inter-laboratory comparison has been conducted on two commercial current and voltage transformers to evaluate the deviation between results obtained by the reference method and those obtained through the simplified method. The experimental results present remarkable consistency between the two methods, with deviations mostly contained within $\pm0.5$~\% and $\pm1$~crad for ratio and phase errors, respectively.