Bas Ten Have

Bas Ten Have

Auto-generated profile, based on publicly available information

Bas Ten Have

Department of EEMCS, University of Twente, Enschede, the Netherlands

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2019 in Renewable Energy and Power Quality Journal
Verified
Journal Article
Closed access
BHBas Ten Have
Bas Ten Have
THTom Hartman
Tom Hartman
Niek MoonenNiek Moonen
Niek Moonen
CKCees Keyer
Cees Keyer
FLFrank Leferink
Frank Leferink
Conducted electromagnetic interference (EMI) can affect the energy readings of static energy meters. Lower readings of static energy meters have been reported in many publications, and higher readings were found when lighting equipment in combination with a dimmer was used as a load. In this paper it is shown that by using an off the shelf water pump as a consumer, faulty deviations on the static meters with respect to a reference meter can be found. In the most extreme case, using a standard mains supply, deviations between -61% and +2675% were found. When an ideal power supply with a standardized mains impedance was used deviations between -19% and +483% were shown to exist.

2 September 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Open access
HBHelko van den Brom
Helko van den Brom
RLRonald van Leeuwen
Ronald van Leeuwen
ZMZander Marais
Zander Marais
BHBas Ten Have
Bas Ten Have
THTom Hartman
Tom Hartman
FLFrank Leferink
Frank Leferink
In 2015, the energy measurement of some static electricity meters was found to be sensitive to specific conducted electromagnetic disturbances with very fast current changes caused by highly nonlinear loads, leading to meter errors up to several hundred percent. This article describes new results on the electromagnetic compatibility (EMC) of 16 different meters from all over Europe when exposed to real-world disturbance signals. Those test signals were obtained from household appliances and onsite measurements at metered supply points all over Europe. The results show that also the interference signals recorded onsite can cause measurement errors as large as several hundred percent, even for meters that pass the present EMC standards. This unambiguously demonstrates that the present immunity testing standards do not cover the most disturbing conducted interference occurring in present daily-life situations due to the increased use of nonlinear electronics. Furthermore, to enable the adoption of potential new test waveforms in future standards for electricity meter testing, artificial test waveforms were constructed based on real-world waveforms using a piece-wise linear model. These artificial test waveforms were demonstrated to cause meter errors similar to those caused by the original real-life waveforms they are representing, showing that they are suitable candidates for use in improved standardization of electricity meter testing.

1 September 2019
Verified
Conference Paper
Closed access
BHBas Ten Have
Bas Ten Have
THTom Hartman
Tom Hartman
Niek MoonenNiek Moonen
Niek Moonen
FLFrank Leferink
Frank Leferink
Static energy meters can be forced to give misreadings due to conducted electromagnetic interference (EMI). In previous research cases lower and higher readings of static energy meters were observed. In this paper an overview of previously reported lab experiments is given and further analyzed. The various situations are showing errors in the energy readings with respect to a reference meter. Based on these findings measurements are done using a dimmer in combination with a series of compact fluorescent lightning (CFL) and light emitting diode (LED) lamps. This setup was powered using a non-distorted mains power supply created by a four-quadrant amplifier combined with a line impedance stabilization network (LISN) to create a stable line impedance. The setup creates a pulsed current waveform with a short rise time. By using various line inductances the slope of the pulse is lowered and a correlation between the inclination of the slope and the deviations of the static meters is shown.

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
YAYawar Abbas
Yawar Abbas
BHBas Ten Have
Bas Ten Have
GHGerrit I. Hoekstra
Gerrit I. Hoekstra
ADArjan Douma
Arjan Douma
DBDouwe de Bruijn
Douwe de Bruijn
ABAlbert van Den Berg
Albert van Den Berg
For the first time, chloride ions are measured wirelessly in concrete. The half-cell potential of a silver/silver chloride (Ag/AgCl) electrode, which corresponds to the concentration of chloride ions, is measured wirelessly. Wireless communication is achieved by an inductive coupling (reflected-impedance) between the coils of the sensor and the readout. The resonance frequency of the sensor coil changes due to the change in the capacitance of a varactor element connected to the Ag/AgCl electrode. The capacitance of the varactor increases with the increase inchloride ion concentration (20 pF/decade). Furthermore, the capacitance can be reliability measured up to a distance of 35mm between sensor and readout coil. No battery is needed to power the sensor terminal, which makes it feasible to embed it in concrete structures

9 April 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Open access
BHBas Ten Have
Bas Ten Have
MAMarco A. Azpurua
Marco A. Azpurua
THTom Hartman
Tom Hartman
MPMarc Pous
Marc Pous
Niek MoonenNiek Moonen
Niek Moonen
FLFrank Leferink
Frank Leferink
This article presents a time-domain waveform model developed to characterize pulsed, nonlinear, current waveforms resulting in electromagnetic interference on static energy meters. The waveform model is calculated by fitting the sampled waveform data into a linear piece-wise function through a process that involves applying algorithms of pulse extraction, change-point detection, and redundancy elimination. The model is applied to data from laboratory experiments that have indicated critical current waveforms resulting in electromagnetic interference problems with static meters. Afterwards, the parameters of the modeled waveforms are calculated in order to correlate them to metering errors. The most relevant parameters that are correlated to significant errors are the maximum slope, crest factor, pulse duration, and charge. The waveform model provides an accurate description of the complex nonlinear waveforms through simplified analytical expressions that reproduce the significant features of the interfering waveforms. This waveform modeling approach could be used to standardize the artificial test signals that are representative of realistic devices and scenarios.

1 June 2019
Verified
Conference Paper
Closed access
BHBas Ten Have
Bas Ten Have
THTom Hartman
Tom Hartman
Niek MoonenNiek Moonen
Niek Moonen
FLFrank Leferink
Frank Leferink