Alfredo Llorente-Álvarez

Alfredo Llorente-Álvarez

Auto-generated profile, based on publicly available information

Alfredo Llorente-Álvarez

Departamento de Construcciones Arquitectónicas, I.T. y M.M.C y T.E., Universidad de Valladolid, Av. de Salamanca, 18, 47014 Valladolid, Spain

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Alberto MeissAlberto Meiss
Alberto Meiss
HJHéctor Jimeno-Merino
Héctor Jimeno-Merino
Irene Poza-CasadoIrene Poza-Casado
Irene Poza-Casado
ALAlfredo Llorente-Álvarez
Alfredo Llorente-Álvarez
MPMiguel Ángel Padilla-Marcos
Miguel Ángel Padilla-Marcos
This paper describes the implementation of a series of ventilation strategies in a nursery and primary school from September 2020, when the government decided to resume the students’ face-to-face activity in the middle of a COVID scenario. Air quality and hygrothermal comfort conditions were analysed before the pandemic and compared for different ventilation configurations in a post-COVID scenario. Ventilation strategies included the protocols issued by the Public Administration, while others were developed based on the typological configuration and use of the school. Results revealed that it is advisable to implement certain strategies that reduce the risk of infection among the occupants of the spaces, without a significant decrease in hygrothermal comfort. Given the importance of maintaining better IAQ in the future within classrooms, and regarding the pre-COVID situation, these strategies may be extended beyond this pandemic period, through a simple protocol and necessary didactic package to be assumed by both teachers and students of the centre.

1 January 2022 in Journal of Cultural Heritage
Verified
Journal Article
Open access
ALAlfredo Llorente-Alvarez
Alfredo Llorente-Alvarez
MCM Soledad Camino-Olea
M Soledad Camino-Olea
ACAlejandro Cabeza-Prieto
Alejandro Cabeza-Prieto
MARIA PAZ SAEZ-PEREZMARIA PAZ SAEZ-PEREZ
MARIA PAZ SAEZ-PEREZ
María Ascensión Rodríguez-EstebanMaría Ascensión Rodríguez-Esteban
María Ascensión Rodríguez-Esteban

4 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
ACAlejandro Cabeza-Prieto
Alejandro Cabeza-Prieto
MCM Soledad Camino-Olea
M Soledad Camino-Olea
MARIA PAZ SAEZ-PEREZMARIA PAZ SAEZ-PEREZ
MARIA PAZ SAEZ-PEREZ
ALAlfredo Llorente-Álvarez
Alfredo Llorente-Álvarez
ARAna-Belén Ramos-Gavilán
Ana-Belén Ramos-Gavilán
María Ascensión Rodríguez-EstebanMaría Ascensión Rodríguez-Esteban
María Ascensión Rodríguez-Esteban
During interventions to improve the energy efficiency of cultural heritage, it is common to use methodologies that are used for current buildings with different thermal behaviour. For this reason, research has been carried out on the thermal behaviour of old brick walls by carrying out thermal flow tests in the laboratory on brickwork specimens, in order to compare the behaviour of handmade bricks and mechanical bricks from more than a century ago, and to analyse the relationship between the values of thermal conductivity, humidity, density and porosity, as well as to compare these results with those obtained by applying the procedure of the EN-1745 standard. It was concluded that bricks behave thermally differently, depending on the manufacturing process: handmade or mechanical, in both types of brick it was found that the higher the moisture content and density were, the higher the brick’s thermal conductivity value. It has also been concluded that old bricks have thermal conductivity values different from those indicated in EN-1745 as a function of density, and that the ratio detected in these specimens in the dry state and in the wet state does not conform to the processes indicated in the standard. With regard to porosity, it is important to note that the greater the closed porosity, the lower the conductivity. It has been concluded that in order to intervene in cultural heritage buildings, it is necessary to carry out a specific study of the behaviour of the systems with which they were constructed.

11 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
Alejandro Cabeza-PrietoAlejandro Cabeza-Prieto
Alejandro Cabeza-Prieto
MCM Soledad Camino-Olea
M Soledad Camino-Olea
María Ascensión Rodríguez-EstebanMaría Ascensión Rodríguez-Esteban
María Ascensión Rodríguez-Esteban
ALAlfredo Llorente-Álvarez
Alfredo Llorente-Álvarez
MARIA PAZ SAEZ-PEREZMARIA PAZ SAEZ-PEREZ
MARIA PAZ SAEZ-PEREZ
To improve the energy performance of restored cultural heritage buildings, it is necessary to know the real values of thermal conductivity of its envelope, mainly of the facades, and to study an intervention strategy that does not interfere with the preservation of their cultural and architectural values. The brick walls with which a large number of these buildings were constructed, usually absorb water, leading to their deterioration, whereas the heat transmission through them is much higher (than when they are dry). This aspect is often not taken into account when making interventions to improve the energy efficiency of these buildings, which makes them ineffective. This article presents the results of an investigation that analyzes thermal behavior buildings of the early 20th century in the city of Zamora, Spain. It has been concluded that avoiding moisture in brick walls not only prevents its deterioration but represents a significant energy saving, especially in buildings that have porous brick masonry walls and with significant thicknesses.

27 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
Alberto MeissAlberto Meiss
Alberto Meiss
Irene Poza-CasadoIrene Poza-Casado
Irene Poza-Casado
ALAlfredo Llorente-Álvarez
Alfredo Llorente-Álvarez
HJHéctor Jimeno-Merino
Héctor Jimeno-Merino
MPMiguel Ángel Padilla-Marcos
Miguel Ángel Padilla-Marcos
The most recent research confirms that airborne transmission may be the dominant mode of SARS-CoV-2 virus spread in the interior spaces of buildings. Consequently, based on some prescriptions that implemented natural ventilation during face-to-face lessons in a university centre, an experimental characterization of several complementary options aimed at reinforcing the prevention and safety of the occupants was carried out. The action protocol adopted was based on the combination of mandatory natural ventilation, a maximum contribution of outdoor air supply in the air conditioning system, and the use of filtering devices located inside the classroom. All the strategies were incorporated concomitantly with necessary compliance with the basic conditions of social distance, occupation, use of masks and guidelines for use and cleaning within educational buildings. The suitability of this protocol was further evaluated throughout the teaching day with students and teachers by measuring the CO2 concentration. The results showed that the measures implemented successfully removed the possible pollutants generated inside.

29 November 2024 in Inżynieria Mineralna
Verified
Journal Article
Open access
PDF file
MCM.S. Camino-Olea
M.S. Camino-Olea
Alejandro Cabeza-PrietoAlejandro Cabeza-Prieto
Alejandro Cabeza-Prieto
MARIA PAZ SAEZ-PEREZMARIA PAZ SAEZ-PEREZ
MARIA PAZ SAEZ-PEREZ
ALA. Llorente-Álvarez
A. Llorente-Álvarez
María Ascensión Rodríguez-EstebanMaría Ascensión Rodríguez-Esteban
María Ascensión Rodríguez-Esteban
Brick masonry walls in Cultural Heritage buildings often have problems caused by rising damp. One solution is to coat the walls with repair mortars, including macroporous mortars. Their function is to ensure that the wall has a lower moisture content than without the coating to reduce deterioration, prevent efflorescence and prevent damp stains. This article presents the conclusions reached on the behaviour of macroporous mortars with regard to water absorption by capillary action and the drying process, by means of laboratory tests carried out on brick and mortar specimens of a similar composition to the old walls, coated with macroporous mortars. From the study it can be concluded that these coatings can help to maintain a lower level of humidity in the masonry before reaching saturation.