Xikun Fu

Xikun Fu

Auto-generated profile, based on publicly available information

Xikun Fu

School of Electrical Engineering and Automation, Wuhan University, Wuhan, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XFXikun Fu
Xikun Fu
JSJianjun Sun
Jianjun Sun
MHmeng huang
meng huang
ZTZhen Tian
Zhen Tian
HYHan Yan
Han Yan
XZXiaoming Zha
Xiaoming Zha
The grid-forming and grid-following controls are adopted in three-phase voltage source converters according to different grid conditions. However, the basic operation principle of the two kinds of control are different and will leads to the instability of the grid-connected system through various paths. In this paper, the energy function model of the grid-forming and grid-following controlled converters are established and compared in detail. The influence of system parameters is studied, and the large-signal stability boundaries are derived through a general method. Moreover, compared to the grid-forming controlled converter, the grid-following converter will lose stability by exhibiting a varying damping coefficient transient. The equivalent damping coefficient can be used as a criterion of whether the grid-forming/following control is suitable for the weak/strong grid condition. The simulation and experiment results show the difference of the transient process and validate the control criterion for different grid strength under large-signal disturbance.

25 February 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XFXikun Fu
Xikun Fu
MHmeng huang
meng huang
SPShangzhi Pan
Shangzhi Pan
XZXiaoming Zha
Xiaoming Zha
In this letter, a cascading synchronization instability phenomenon is reported in a multi-voltage-source-converter (VSC) grid. By adopting the equal area criterion, it is revealed that during the fault transient, there is static interaction that increases equivalent mechanical power for the original stable-operating VSC. Due to the fast power angle swing of the unstable VSC, there is nonnegligible dynamic interaction, which may decrease its synchronization stability margin. The effect of system parameters on synchronization stability is studied, and the simulation and experimental results verify the analysis.

28 April 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ZTZhen Tian
Zhen Tian
YTYingjie Tang
Yingjie Tang
XZXiaoming Zha
Xiaoming Zha
JSJianjun Sun
Jianjun Sun
MHmeng huang
meng huang
FLFei Liu
Fei Liu
As the crucial interface of renewable energy integration, the stable operation of power converters under grid faults and external disturbances has become much more important. However, synchronization instability of grid-tied inverters has been found caused by the phase-locked loop (PLL) under some critical operating conditions, such as the grid voltage sag, current surge, and transmission line faults. Due to the strong nonlinearity, transient stability analysis of inverters with PLL becomes much more complicated under large-signal perturbations and weak grid conditions. In this article, the large-signal synchronization stability of grid-tied inverters is investigated from the energy perspective. Based on the structural resemblance between the PLL and synchronous generator, the energy function is constructed to establish a port-Hamiltonian model for the grid-tied inverter. For the nonlinear inverter system, an explicit Hamilton-based stability criterion is developed for grid-tied converters according to the concept of dissipativity and LaSalle’s theorem. Moreover, the analytical stability boundary is acquired based on the proposed stability criterion and attraction region estimation, covering both controller parameters and grid parameters. To verify the effectiveness of the proposed analysis approach, extensive simulation and experimental results are presented. Compared with the conventional large-signal methods, the proposed Hamilton-based approach has explicit physical meaning and high accuracy.

29 March 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
XFXikun Fu
Xikun Fu
MHmeng huang
meng huang
CTChi K. Tse
Chi K. Tse
JYJingxi Yang
Jingxi Yang
YLYangjian Ling
Yangjian Ling
XZXiaoming Zha
Xiaoming Zha
In the grid-following (GFL) voltage source converter (VSC), the synchronization process of phase-locked loop (PLL) can be seriously affected by the interactions from the inner current loop and other parallel-connected VSCs. In this paper, we focus on the influences of these interactions on the synchronization stability of GFL-VSC. Firstly, these interactions are classified into static and dynamic interactions by the mechanism of how they affect the dynamic of PLL. Then, their influence on the synchronization stability is estimated based on a novel Lyapunov stability criterion, which is derived from the extended invariance principle. On this basis, in terms of the physical mechanism, we reveal how the VSC exhibits the non-asymptotic synchronization (i.e., limit cycles) and cascading synchronization instability. In addition, we get the maximum range of static and dynamic interactions that the VSC endure, which can provide the practical design guidance for the VSC. Finally, simulations and experiments are performed to verify the theoretical findings.

4 May 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JYJingxi Yang
Jingxi Yang
CTChi K. Tse
Chi K. Tse
MHmeng huang
meng huang
XFXikun Fu
Xikun Fu
Under transient disturbance, the grid-forming voltage-source converter may lose its synchronization with the grid, inducing sustained low-frequency oscillation in instantaneous power, current, and phase angle. The physical origin of such oscillations is found to be a homoclinic bifurcation in this article. Before the system runs into a homoclinic bifurcation, a stable equilibrium point (SEP) and a stable periodic orbit coexist. When a large transient disturbance is applied, the system exhibits a periodic orbit, which manifests itself as low-frequency oscillation. Moreover, after the homoclinic bifurcation, the periodic orbit subsides, and only a single attractor, the SEP, exists in the phase space. In this case, the grid-forming converter is able to resynchronize with the grid even under transient disturbances. Bifurcation diagrams are derived as the boundaries of stable operation in the parameter space, which serve as practical design guidelines to avoid sustained oscillations. Cycle-by-cycle simulations and laboratory experiments are performed to verify the analytical findings.

19 June 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JYJingxi Yang
Jingxi Yang
CTChi K. Tse
Chi K. Tse
MHmeng huang
meng huang
DLDong Liu
Dong Liu
CLChao Charles Liu
Chao Charles Liu
XFXikun Fu
Xikun Fu
A second-order model is developed to describe the essential behavior of the grid-following converter (GFLC) and the grid-forming converter (GFMC) for studying the synchronization characteristics of grid-connected converter systems. In this article, a general set of criteria in terms of the manifolds and saddle quantity is derived for studying the homoclinic bifurcation behavior of GFLCs and GFMCs. It is shown that three unstable periodic orbits and two homoclinic bifurcations may exist for the GFLC, while only one stable periodic orbit and one homoclinic bifurcation may exist for the GFMC. It is also found that after the onset of the first homoclinic bifurcation, the stable equilibrium point (SEP) is surrounded by the stable manifolds of the unstable equilibrium point (UEP), which forms the SEP's basin of attraction, for both GFLCs and GFMCs. In this case, the converters may lose their synchronization if the trajectory crosses over the UEP. Therefore, system parameters should be designed to avoid the onset of the aforementioned bifurcation so that the SEP's basin of attraction can be significantly enlarged to contain the UEP. As a result, the GFLC or GFMC can eventually resynchronize with the grid even when its trajectory passes the UEP. Finally, experimental results are provided to verify these theoretical findings.