Varun V. Soman

Varun V. Soman

Auto-generated profile, based on publicly available information

Varun V. Soman

Small Scale Systems Integration and Packaging Center, Binghamton University, Binghamton, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YGYang Gao
Yang Gao
VSVarun V. Soman
Varun V. Soman
JLJack P. Lombardi
Jack P. Lombardi
PRPravakar Prasad Rajbhandari
Pravakar Prasad Rajbhandari
TDTara P Dhakal
Tara P Dhakal
ZJZhanpeng Jin
Zhanpeng Jin
Noninvasive sensors capable of measuring weak biopotential signals, such as electrocardiogram (ECG) and EEG, and communicating results wirelessly to a host computer are developing rapidly. Some of them utilize capacitively coupled electrodes in an attempt to place the sensor at a distance from the skin. This article demonstrated the fabrication and development of a capacitively coupled ECG electrode prototype using custom high specific capacitance electrodes and custom high-performance electronics. Two ultrathin capacitive electrodes were fabricated on a flexible polyimide substrate (2 × 2 in) protected by a guard ring to reduce noise. The detection and amplification circuitry consisted of operational amplifiers (OpAmps) that filtered and conditioned the ECG signal. R-peaks in the ECG were readily detected and quantified using both simulated signals from ECG databases and real signals from human subjects. Heart rates and heart rate variability calculated from our monitor measurements were comparable with commercial rigid wearable sensors, including a smartwatch and an ECG monitor that uses standard clinical ionic electrodes. The prototype monitor was tested on human subjects during rest and moderate exercise and showed appropriate responses. The challenge of high-gain low-noise amplification was met by the development of highly thinned OpAmps whose operation was shown to be equivalent to commercially available rigidly packaged OpAmps, demonstrating that high-performance Si-electronics can be used to produce high-fidelity signals from weak biopotentials.

31 May 2019 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
VSVarun V. Soman
Varun V. Soman
DHDonggeon Han
Donggeon Han
AAAna Claudia Arias
Ana Claudia Arias
KGKanad Ghose
Kanad Ghose
MPMark Poliks
Mark Poliks
NYNatasha A. D. Yamamoto
Natasha A. D. Yamamoto
Flexible hybrid electronics (FHE) interface rigid electronic components with flexible sensors, circuits, and substrates. This paper reports the reliability improvement of a FHE Human Performance Monitor (HPM), designed to monitor electrocardiography (ECG) signals. The 50.8 mm × 50.8 mm HPM is fabricated on Kapton® HN polyimide (PI) substrate with flexible gold (Au) ECG electrodes on one side of the substrate and rigid electronic components for signal processing and communication mounted on the other side of the substrate. Our previously reported HPMs demonstrated reliability issues due to (1) cracking of the copper (Cu) circuitry, and (2) thinning and lack of adhesion at the printed Au and plated Cu interface that connected printed sensors to the Cu circuitry. Both failure mechanisms resulted in electrical opens in the circuit, which caused device failure. We explored effect of different design parameters, such as PI substrate thickness (50 μm vs 125 μm), Cu circuit thickness (2 μm vs 6 μm), solder reflow temperature (205 °C for Tin-Lead (Sn-Pb) vs 175 ° for Tin-Bismuth (Sn-Bi) solder), solder pad design, and optimized inkjet printing (printing on bare Cu vs Au plated Cu) on improving FHE reliability. Test vehicles (TVs) with different combinations of these factors were fabricated and bend tested to determine the most robust configuration. TVs with 50 μm thick PI substrate, 6 μm thick Cu circuit, Sn-Bi solder, redesigned solder pads with rounded corners, and printed Au traces on Au plated Cu pads demonstrated the best reliability results.