Jakub Baran

Jakub Baran

Auto-generated profile, based on publicly available information

Jakub Baran

Jagiellonian University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in NeuroImage
Verified
Journal Article
Closed access
SJSharna D. Jamadar
Sharna D. Jamadar
PWPhillip Gd. Ward
Phillip Gd. Ward
SLShenpeng Li
Shenpeng Li
FSFrancesco Sforazzini
Francesco Sforazzini
JBJakub Baran
Jakub Baran
GEGary F Egan
Gary F Egan

13 September 2024 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
JBJakub Baran
Jakub Baran
SBSteven Bass
Steven Bass
JCJarosław Choiński
Jarosław Choiński
NCNeha Chug
Neha Chug
Ewa Łucja StępieńEwa Łucja Stępień
Ewa Łucja Stępień
Positronium is abundantly produced within the molecular voids of a patient’s body during positron emission tomography (PET). Its properties dynamically respond to the submolecular architecture of the tissue and the partial pressure of oxygen. Current PET systems record only two annihilation photons and cannot provide information about the positronium lifetime. This study presents the in vivo images of positronium lifetime in a human, for a patient with a glioblastoma brain tumor, by using the dedicated Jagiellonian PET system enabling simultaneous detection of annihilation photons and prompt gamma emitted by a radionuclide. The prompt gamma provides information on the time of positronium formation. The photons from positronium annihilation are used to reconstruct the place and time of its decay. In the presented case study, the determined positron and positronium lifetimes in glioblastoma cells are shorter than those in salivary glands and those in healthy brain tissues, indicating that positronium imaging could be used to diagnose disease in vivo.

4 August 2018 in Human Brain Mapping
Verified
Journal Article
Closed access
PDF file
ZCZhaolin Chen
Zhaolin Chen
SJSharna D. Jamadar
Sharna D. Jamadar
SLShenpeng Li
Shenpeng Li
FSFrancesco Sforazzini
Francesco Sforazzini
JBJakub Baran
Jakub Baran
GEGary F Egan
Gary F Egan

11 November 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
DBDamian Borys
Damian Borys
JBJakub Baran
Jakub Baran
KBKarol Brzeziński
Karol Brzeziński
JGJan Gajewski
Jan Gajewski
NCNeha Chug
Neha Chug
ARAntoni Rucinski
Antoni Rucinski
Objective. This paper reports on the implementation and shows examples of the use of the ProTheRaMon framework for simulating the delivery of proton therapy treatment plans and range monitoring using positron emission tomography (PET). ProTheRaMon offers complete processing of proton therapy treatment plans, patient CT geometries, and intra-treatment PET imaging, taking into account therapy and imaging coordinate systems and activity decay during the PET imaging protocol specific to a given proton therapy facility. We present the ProTheRaMon framework and illustrate its potential use case and data processing steps for a patient treated at the Cyclotron Centre Bronowice (CCB) proton therapy center in Krakow, Poland. Approach. The ProTheRaMon framework is based on GATE Monte Carlo software, the CASToR reconstruction package and in-house developed Python and bash scripts. The framework consists of five separated simulation and data processing steps, that can be further optimized according to the user’s needs and specific settings of a given proton therapy facility and PET scanner design. Main results. ProTheRaMon is presented using example data from a patient treated at CCB and the J-PET scanner to demonstrate the application of the framework for proton therapy range monitoring. The output of each simulation and data processing stage is described and visualized. Significance. We demonstrate that the ProTheRaMon simulation platform is a high-performance tool, capable of running on a computational cluster and suitable for multi-parameter studies, with databases consisting of large number of patients, as well as different PET scanner geometries and settings for range monitoring in a clinical environment. Due to its modular structure, the ProTheRaMon framework can be adjusted for different proton therapy centers and/or different PET detector geometries. It is available to the community via github (Borys et al 2022).

3 January 2019 in Human Brain Mapping
Verified
Journal Article
Open access
PDF file
ZCZhaolin Chen
Zhaolin Chen
FSFrancesco Sforazzini
Francesco Sforazzini
JBJakub Baran
Jakub Baran
TCThomas Close
Thomas Close
NSN. Jon Shah
N. Jon Shah
GEGary F Egan
Gary F Egan
Head motion is a major source of image artefacts in neuroimaging studies and can lead to degradation of the quantitative accuracy of reconstructed PET images. Simultaneous magnetic resonance‐positron emission tomography (MR‐PET) makes it possible to estimate head motion information from high‐resolution MR images and then correct motion artefacts in PET images. In this article, we introduce a fully automated PET motion correction method, MR‐guided MAF, based on the co‐registration of multicontrast MR images. The performance of the MR‐guided MAF method was evaluated using MR‐PET data acquired from a cohort of ten healthy participants who received a slow infusion of fluorodeoxyglucose ([18‐F]FDG). Compared with conventional methods, MR‐guided PET image reconstruction can reduce head motion introduced artefacts and improve the image sharpness and quantitative accuracy of PET images acquired using simultaneous MR‐PET scanners. The fully automated motion estimation method has been implemented as a publicly available web‐service.

12 July 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
KBKarol Brzeziński
Karol Brzeziński
JBJakub Baran
Jakub Baran
DBDamian Borys
Damian Borys
JGJan Gajewski
Jan Gajewski
NCNeha Chug
Neha Chug
ARAntoni Rucinski
Antoni Rucinski
Objective. The Jagiellonian positron emission tomography (J-PET) technology, based on plastic scintillators, has been proposed as a cost effective tool for detecting range deviations during proton therapy. This study investigates the feasibility of using J-PET for range monitoring by means of a detailed Monte Carlo simulation study of 95 patients who underwent proton therapy at the Cyclotron Centre Bronowice (CCB) in Krakow, Poland. Approach. Discrepancies between prescribed and delivered treatments were artificially introduced in the simulations by means of shifts in patient positioning and in the Hounsfield unit to the relative proton stopping power calibration curve. A dual-layer, cylindrical J-PET geometry was simulated in an in-room monitoring scenario and a triple-layer, dual-head geometry in an in-beam protocol. The distribution of range shifts in reconstructed PET activity was visualized in the beam’s eye view. Linear prediction models were constructed from all patients in the cohort, using the mean shift in reconstructed PET activity as a predictor of the mean proton range deviation. Main results. Maps of deviations in the range of reconstructed PET distributions showed agreement with those of deviations in dose range in most patients. The linear prediction model showed a good fit, with coefficient of determination r 2 = 0.84 (in-room) and 0.75 (in-beam). Residual standard error was below 1 mm: 0.33 mm (in-room) and 0.23 mm (in-beam). Significance. The precision of the proposed prediction models shows the sensitivity of the proposed J-PET scanners to shifts in proton range for a wide range of clinical treatment plans. Furthermore, it motivates the use of such models as a tool for predicting proton range deviations and opens up new prospects for investigations into the use of intra-treatment PET images for predicting clinical metrics that aid in the assessment of the quality of delivered treatment.