3 November 2023 in IEEE Transactions on Power Electronics
The hybrid soft open point (HSOP), formed by the parallel combination of the normally open point (NOP) and the soft open point (SOP), combines the advantages of flexibility and high cost-efficiency. At the power outage moment, the seamless switching process of HSOP contains a co-operation state with NOP and SOP parallel working together. This state involves current transitions between NOP and SOP, which may cause overcurrent and trigger the protection shutdown. To address this issue, a wide-band mathematical model is established to analyze and evaluate the transiting current, including high-frequency transiting current caused by the phase difference of pulsewidth modulation, and low-frequency overcurrent caused by a grid voltage step change. Based on the analysis, a high-frequency overcurrent limitation strategy is introduced, relying on the synchronization modulation strategy, and a low-frequency overcurrent limitation strategy is proposed, based on virtual impedance. The effectiveness of the proposed strategy is validated by operating the whole switching process with the simulation and a downscaled experimental platform. According to the experimental results, the SOP can support the load voltage within 20 ms after the power outage. Moreover, the high-frequency currents can be suppressed to around 10% compared to extreme cases, and the low-frequency overcurrent can be completely inhibited.
15 June 2026 in IEEE Transactions on Instrumentation and Measurement
The integration of the distributed generations (DG) stations distorts the conventional single-phase grounding (SPG) fault localization results. Considering the flexibility of DGs, a novel SPG fault localization methodology for the neutral non-effectively grounded distribution networks is proposed in this article. In the proposed method, DGs are controlled to inject the harmonic currents to actively participate in the localization process. Firstly, the SPG fault characteristic at the harmonic frequency is analyzed, and the measured harmonic impedance at the feeder junction is shown to correlate with the fault distance. Subsequently, typical control strategies of the grid-following and grid-forming DGs under the SPG fault are modified to assist the harmonic impedance detection. Then, the coupling effect between DGs at various feeders is studied, and this coupling effect is eliminated by modifying the output impedance of the control-heterogeneous DGs at the special frequency band. Finally, the SPG fault localization can be realized through the coordination operation of the multiple control-heterogeneous DGs, and the simulation model and the hardware-in-loop experimental results verify the effectiveness under various testing conditions.
23 December 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The DC-link capacitors in back-to-back (BTB) converters perform as a necessary DC-link voltage supporter and power buffer for both sides. However, the DC-link capacitor is normally over-designed due to performance considerations, causing a larger volume and higher cost. This article proposes a more comprehensive and accurate design scheme of the DC-link capacitance for the BTB three-level neutral point clamped converter, achieving the DC bus lightweight design. Multidimensional aspects are considered when quantifying the capacitance constraints, including small-signal interactive stability, DC-link voltage fluctuation facing a given power step change from both AC sides, and switching ripple filtering performances. Corresponding to the above multidimensional aspects, the stability constraint, response speed constraint, and filtering performance constraint of the DC-link capacitance and the control parameter value are analyzed. Additionally, the active capacitor is adopted to suppress the neutral point voltage low-frequency oscillation and to avoid the unfavorable boundary reduction of the DC-link capacitance selection. The effectiveness of the proposed lightweight DC-link capacitance design scheme is validated through simulations and experimental results. Experimental results indicate that the DC-link capacitance of each converter can be reduced to 10μF in the 2kW experimental BTB converter, realizing over 60% volume reduction of the DC bus compared with conventional designs.
11 June 2026 in International Journal of Electrical Power & Energy Systems
10 March 2026 in SSRN Electronic Journal
The conventional overcurrent protection fails to isolate the permanent short-circuit fault with the power electronic converters interface, hindering the utilization of various converters for power supply restoration. A novel protection scheme based on the harmonic undervoltage is proposed in this paper to realize accurate and rapid fault isolation. From the system-level perspective, the three-stage harmonic undervoltage protection method is proposed, enabling coordinated operation between primary and backup protection. The operation principle, parameter design, and extension scheme for complex networks of the novel protection method are introduced, enhancing the computational efficiency and adaptability. From the converter-level perspective, the transient overcurrent limited strategy based on voltage feedforward dynamic gain adjustment is presented for avoiding undesired device shutdown during faults. Besides, the active harmonic injection loop is added to the control system, assisting the operation of the proposed protection method. The simulation and the experimental results indicate that the above method can rapidly locate various short-circuit faults in networks with converters, facilitating flexible control of the distribution networks.