Zebin Yang

Zebin Yang

Auto-generated profile, based on publicly available information

Zebin Yang

State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ZYZebin Yang
Zebin Yang
HYHao Yi
Hao Yi
FZFang Zhuo
Fang Zhuo
XYXiaoqing Yin
Xiaoqing Yin
WWWei Wei
Wei Wei
QWQing Wang
Qing Wang
The decentralized distribution of nonlinear harmonic loads drives the trend of harmonic control from local compensation to system-level mitigation. Based on the active power filter (APF) with multi-bus harmonic detections, comprehensive control of harmonic distortions in multiple buses achieves, which is so-called system-level harmonic mitigation. However, existing system-level harmonic mitigation methods require high-speed data exchange for real-time phase synchronization among multiple buses, which reduces the feasibility of the methods. To reduce the burden of communication, a system-level harmonic mitigation method without inter-bus phase synchronization is proposed in this paper. Firstly, the phase synchronization problem is analyzed, and control system of multi-bus detected APF is proposed, in which the reference phase of each detector could be set locally. Then, a new online system-level harmonic mitigation model is introduced and solved to obtain the optimal APF current reference. Subsequently, the closed-loop control strategy of multi-bus detected APF is raised and four control stages are designed to cope with different situations. Finally, an eight-bus network with dynamic harmonic loads is designed in simulation and experiment. According to the results, multi-bus harmonic voltage distortions in the network could meet the standard. The proposed method contributes to achieving good harmonic compensation performance without multi-bus phase-synchronization.

22 December 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ZYZebin Yang
Zebin Yang
HYHao Yi
Hao Yi
FZFang Zhuo
Fang Zhuo
XYXiaoqing Yin
Xiaoqing Yin
WWWei Wei
Wei Wei
QWQing Wang
Qing Wang
With the massive and distributed access of nonlinear loads to distribution networks, traditional point-to-point harmonic compensation method becomes inefficient. Meanwhile, the demand for system-level harmonic control by few shunt active power filters (SAPFs) has emerged, which lays emphasis on the optimal allocation and coordination of SAPFs, in terms of location, capacity and output. Existing allocation algorithms suffer from local minimum, characterized by excessive locations and unreasonable capacity assignment of SAPFs. Therefore, this paper introduces a new nonlinear loads partition model and a cluster-based SAPFs allocation algorithm. Firstly, the existing basic SAPFs allocation model is reviewed for problem description. By reconstructing the existing model, a three-level nonlinear loads partition model is built, in which the essence of system-level harmonic control is revealed and the harmonic compensation distance between SAPF and the nonlinear load is defined. Based on this distance, a modified K-means clustering algorithm is implemented to partition nonlinear loads and obtain the optimal allocation of SAPFs. Finally, the IEEE 18-bus standard system and its simplified 8-bus network are designed respectively in simulation and experiment. Results verify that the proposed SAPFs allocation method has the advantages of less location, less total capacity and good harmonic suppression performance.

18 April 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YLYuguo Li
Yuguo Li
HYHao Yi
Hao Yi
ZYZebin Yang
Zebin Yang
XJXin Jiang
Xin Jiang
The dynamic interaction between voltage-source converters (VSC) and the grid may lead to high-frequency destabilization (HFDS). It has been shown that HFDS can be effectively avoided if the VSC input admittance (VIA) is compensated to be passive at all the frequencies below Nyquist frequency (NF). The effective approaches, auxiliary current feedback and advanced control sequence (i.e., oversampling or delayed sampling), are limited for cost-sensitive applications. Without the above approaches, full-range passive VIA is hard to achieve, even if existing self-tuning active damping methods are used. Therefore, this article proposes an adaptive parameter switching voltage-feedback active damping control (AFVC) method. Both positive and negative feedback are used to design preset AFVC parameters, making VIA passive in different ranges, which overlap and cover the frequencies below NF. Parameter switching is triggered by fast Fourier transformation (FFT). The data sequence length of FFT is designed to balance the speed and frequency spectrum resolution. Sampling frequency aliasing and PWM sideband frequency coupling challenge the admittance/impedance based stability analysis around NF, so they are modeled and proved to be negligible for high-frequency stability. The effectiveness of the proposed method is verified by both simulation and experiment.

23 December 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ZLZhenhong Lai
Zhenhong Lai
HYHao Yi
Hao Yi
KWKaihua Wu
Kaihua Wu
Zhenxiong WangZhenxiong Wang
Zhenxiong Wang
ZYZebin Yang
Zebin Yang
FZFang Zhuo
Fang Zhuo
The DC-link capacitors in back-to-back (BTB) converters perform as a necessary DC-link voltage supporter and power buffer for both sides. However, the DC-link capacitor is normally over-designed due to performance considerations, causing a larger volume and higher cost. This article proposes a more comprehensive and accurate design scheme of the DC-link capacitance for the BTB three-level neutral point clamped converter, achieving the DC bus lightweight design. Multidimensional aspects are considered when quantifying the capacitance constraints, including small-signal interactive stability, DC-link voltage fluctuation facing a given power step change from both AC sides, and switching ripple filtering performances. Corresponding to the above multidimensional aspects, the stability constraint, response speed constraint, and filtering performance constraint of the DC-link capacitance and the control parameter value are analyzed. Additionally, the active capacitor is adopted to suppress the neutral point voltage low-frequency oscillation and to avoid the unfavorable boundary reduction of the DC-link capacitance selection. The effectiveness of the proposed lightweight DC-link capacitance design scheme is validated through simulations and experimental results. Experimental results indicate that the DC-link capacitance of each converter can be reduced to 10μF in the 2kW experimental BTB converter, realizing over 60% volume reduction of the DC bus compared with conventional designs.