Chih-Hsien Lai

Chih-Hsien Lai

Auto-generated profile, based on publicly available information

Chih-Hsien Lai

National Yunlin University of Science and Technology

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YCYuan-Fong Chau
Yuan-Fong Chau
KCKuan-Hung Chen
Kuan-Hung Chen
Hai-Pang ChiangHai-Pang Chiang
Hai-Pang Chiang
CLChee Ming Lim
Chee Ming Lim
Hung Ji HuangHung Ji Huang
Hung Ji Huang
Roshan ThotagamugeRoshan Thotagamuge
Roshan Thotagamuge
In this paper, a periodic metallic–dielectric nanorod array which consists of Si nanorods coated with 30 nm Ag thin film set in a hexagonal configuration is fabricated and characterized. The fabrication procedure is performed by using nanosphere lithography with reactive ion etching, followed by Ag thin-film deposition. The mechanism of the surface and gap plasmon modes supported by the fabricated structure is numerically demonstrated by the three-dimensional finite element method. The measured and simulated absorptance spectra are observed to have a same trend and a qualitative fit. Our fabricated plasmonic sensor shows an average sensitivity of 340.0 nm/RIU when applied to a refractive index sensor ranging from 1.0 to 1.6. The proposed substrates provide a practical plasmonic nanorod-based sensing platform, and the fabrication methods used are technically effective and low-cost.

1 September 2019 in Vacuum
Verified
Journal Article
Closed access
YNYu-Hsun Nien
Yu-Hsun Nien
HCHuang-Hua Chen
Huang-Hua Chen
HHHui-Hsuan Hsu
Hui-Hsuan Hsu
PKPo-Yu Kuo
Po-Yu Kuo
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
CKCheng-Chu Ko
Cheng-Chu Ko

13 November 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JCJung-Chuan Chou
Jung-Chuan Chou
SYSiao-Jie Yan
Siao-Jie Yan
YLYi-Hung Liao
Yi-Hung Liao
CLChih-Hsien Lai
Chih-Hsien Lai
JCJian-Syun Chen
Jian-Syun Chen
TWTong-Yu Wu
Tong-Yu Wu
In this study, nickel oxide (NiO) was used as sensing film of flexible arrayed NiO pH sensor, and its average sensitivity could be improved by introducing oxygen gas in sputtering deposition process for NiO sensing film. It had the advantage such as portability, disposability, low cost, high flexibility, miniaturization, long-term stability for basic solution and high sensitivity (63 mV/pH) exhibited in the pH range from pH 1 to pH 13. Moreover, the characteristics of optimal NiO sensing film were investigated by using field emission scanning electron microscope. The non-ideal effects of flexible arrayed NiO pH sensor were investigated, such as drift and hysteresis effects. The drift rates for pH 1, pH 7 and pH 13 were -4 mV/hr, 3 mV/hr and 1 mV/hr, respectively. Moreover, the hysteresis voltages were within 4 mV.

11 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
SLSi-Hong Lin
Si-Hong Lin
TLTsu-Yang Lai
Tsu-Yang Lai
Po-Yu KuoPo-Yu Kuo
Po-Yu Kuo
CLChih-Hsien Lai
Chih-Hsien Lai
TSTzu-Yu Su
Tzu-Yu Su
In this study, the potentiometric arrayed glucose biosensors, which were based on zinc oxide (ZnO) or aluminum-doped zinc oxide (AZO) sensing membranes, were fabricated by using screen-printing technology and a sputtering system, and graphene oxide (GO) and Nafion-glucose oxidase (GOx) were used to modify sensing membranes by using the drop-coating method. Next, the material properties were characterized by using a Raman spectrometer, a field-emission scanning electron microscope (FE-SEM), and a scanning probe microscope (SPM). The sensing characteristics of the glucose biosensors were measured by using the voltage–time (V-T) measurement system. Finally, electrochemical impedance spectroscopy (EIS) was conducted to analyze their charge transfer abilities. The results indicated that the average sensitivity of the glucose biosensor based on Nafion-GOx/GO/AZO was apparently higher than that of the glucose biosensor based on Nafion-GOx/GO/ZnO. In addition, the glucose biosensor based on Nafion-GOx/GO/AZO exhibited an excellent average sensitivity of 15.44 mV/mM and linearity of 0.997 over a narrow range of glucose concentration range, a response time of 26 s, a limit of detection (LOD) of 1.89 mM, and good reproducibility. In terms of the reversibility and stability, the hysteresis voltages (VH) were 3.96 mV and 2.42 mV. Additionally, the glucose biosensor also showed good anti-inference ability and reproducibility. According to these results, it is demonstrated that AZO is a promising material, which could be used to develop a reliable, simple, and low-cost potentiometric glucose biosensor.

31 January 2019 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
CWCian-Yi Wu
Cian-Yi Wu
Po-Yu KuoPo-Yu Kuo
Po-Yu Kuo
CLChih-Hsien Lai
Chih-Hsien Lai
YNYu-Hsun Nien
Yu-Hsun Nien
YLYi-Hung Liao
Yi-Hung Liao
A flexible urea sensor based on urease-magnetic beads (MBs) and graphene oxide (GO) has been synthesized on nickel oxide (NiO) as matrix. The flexible urea sensor was constructed by sputtering technology and screen-printing technology. A sequential titrating of GO and magnetic beads over the surface on NiO film was adopted for the sensor preparation by the covalent binding with urease. The electrochemical impedance, response time and drift effect of the urea sensor based on MBs, GO and NiO were recorded using electrochemical impedance spectroscopy (EIS) and voltage-time (V-T) measurement system.

8 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
CWCian-Yi Wu
Cian-Yi Wu
SLSi-Hong Lin
Si-Hong Lin
Po-Yu KuoPo-Yu Kuo
Po-Yu Kuo
CLChih-Hsien Lai
Chih-Hsien Lai
TLTsu-Yang Lai
Tsu-Yang Lai
Two types of urea biosensors were integrated with a wireless measurement system and microfluidic measurement system. The two biosensors used were (i) a magnetic beads (MBs)-urease/graphene oxide (GO)/titanium dioxide (TiO2)-based biosensor and (ii) an MBs-urease/GO/ nickel oxide (NiO)-based biosensor, respectively. The wireless measurement system work exhibited the feasibility for the remote detection of urea, but it will require refinement and modification to improve stability and precision. The microchannel fluidic system showed the measurement reliability. The sensing properties of urea biosensors at different flow rates were investigated. From the measurement results, the decay of average sensitivity may be attributed to the induced vortex-induced vibrations (VIV) at the high flow rate. In the aspect of wireless monitoring, the average sensitivity of the urea biosensor based on MBs-urease/GO/NiO was 4.780 mV/(mg/dl) and with the linearity of 0.938. In the aspect of measurement under dynamic conditions, the average sensitivity of the urea biosensor based on MBs-urease/GO/NiO were 5.582 mV/(mg/dl) and with the linearity of 0.959. Both measurements performed NiO was better than TiO2 according to the comparisons.