Vishal Dhamgaye

Vishal Dhamgaye

Auto-generated profile, based on publicly available information

Vishal Dhamgaye

Diamond Light Source, Didcot, United Kingdom

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2019 in Optica
Verified
Journal Article
Closed access
PDF file
DLDavid Laundy
David Laundy
VDVishal Dhamgaye
Vishal Dhamgaye
TMThomas Moxham
Thomas Moxham
Kawal SawhneyKawal Sawhney
Kawal Sawhney
Advances in x-radiation sources put greater demands on x-ray optics. Fabrication errors in optical elements lead to deformation of the radiation wavefront, which prevents diffraction-limited imaging of the source. A new adaptable x-ray phase compensator using refracting elements has been developed, fabricated, and tested. The compensator makes a sinusoidal correction to the x-ray wavefront with variable amplitude, period, and phase. The adaptable compensator was used to correct two planar compound refractive lenses and a Kirkpatrick–Baez mirror system on an x-ray beamline. Wavefront measurements showed a reduction in the rms wavefront error by a factor of seven for the lenses and three for the mirror system, reducing rms wavefront errors down to of order $ \lambda /100 $. This concept could be used with optics on existing x-ray beamlines to enable diffraction-limited focusing.

19 October 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
VDVishal Dhamgaye
Vishal Dhamgaye
DLDavid Laundy
David Laundy
SBSara Baldock
Sara Baldock
TMThomas Moxham
Thomas Moxham
Kawal SawhneyKawal Sawhney
Kawal Sawhney
A refractive phase corrector optics is proposed for the compensation of fabrication error of X-ray optical elements. Here, at-wavelength wavefront measurements of the focused X-ray beam by knife-edge imaging technique, the design of a three-dimensional corrector plate, its fabrication by 3D printing, and use of a corrector to compensate for X-ray lens figure errors are presented. A rotationally invariant corrector was manufactured in the polymer IP-STM using additive manufacturing based on the two-photon polymerization technique. The fabricated corrector was characterized at the B16 Test beamline, Diamond Light Source, UK, showing a reduction in r.m.s. wavefront error of a Be compound refractive Lens (CRL) by a factor of six. The r.m.s. wavefront error is a figure of merit for the wavefront quality but, for X-ray lenses, with significant X-ray absorption, a form of the r.m.s. error with weighting proportional to the transmitted X-ray intensity has been proposed. The knife-edge imaging wavefront-sensing technique was adapted to measure rotationally variant wavefront errors from two different sets of Be CRL consisting of 98 and 24 lenses. The optical aberrations were then quantified using a Zernike polynomial expansion of the 2D wavefront error. The compensation by a rotationally invariant corrector plate was partial as the Be CRL wavefront error distribution was found to vary with polar angle indicating the presence of non-spherical aberration terms. A wavefront correction plate with rotationally anisotropic thickness is proposed to compensate for anisotropy in order to achieve good focusing by CRLs at beamlines operating at diffraction-limited storage rings.

8 March 2021 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
TMThomas Moxham
Thomas Moxham
DLDavid Laundy
David Laundy
VDVishal Dhamgaye
Vishal Dhamgaye
OFOliver J. L. Fox
Oliver J. L. Fox
Kawal SawhneyKawal Sawhney
Kawal Sawhney
Alexander KorsunskyAlexander Korsunsky
Alexander Korsunsky
Ptychography is a scanning coherent diffraction imaging technique that provides high-resolution imaging and complete spatial information of the complex probe and object transmission function. The wavefront error caused by aberrated optics has previously been recovered using ptychography when a highly coherent source is used, but has not been demonstrated with partial coherence due to the multi-modal probe required. Here, we demonstrate that partial coherence can be accounted for in ptychographic reconstructions using the multi-modal approach and assuming that decoherence arises from either the probe or the object. This equivalence recovers coherent (or single state) reconstructions of both the probe and the object even in the presence of partial coherence. We demonstrate this experimentally by using hard x-ray ptychography with a partially coherent source to image a Siemens star test object and to also recover the wavefront error from an aberrated beryllium compound refractive lens. The source properties and resolving capabilities are analyzed, and the wavefront error results are compared with another at-wavelength metrology technique. Our work demonstrates the capability of ptychography to provide high-resolution imaging and optics characterization even in the presence of partial coherence.

16 October 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
TMThomas Moxham
Thomas Moxham
APAaron Parsons
Aaron Parsons
TZTunhe Zhou
Tunhe Zhou
LALucia Alianelli
Lucia Alianelli
HWHongchang Wang
Hongchang Wang
Alexander KorsunskyAlexander Korsunsky
Alexander Korsunsky
Ptychography is a scanning coherent diffraction imaging technique which provides high resolution imaging and complete spatial information of the complex electric field probe and sample transmission function. Its ability to accurately determine the illumination probe has led to its use at modern synchrotrons and free-electron lasers as a wavefront-sensing technique for optics alignment, monitoring and correction. Recent developments in the ptychography reconstruction process now incorporate a modal decomposition of the illuminating probe and relax the restriction of using sources with high spatial coherence. In this article a practical implementation of hard X-ray ptychography from a partially coherent X-ray source with a large number of modes is demonstrated experimentally. A strongly diffracting Siemens star test sample is imaged using the focused beam produced by either a Fresnel zone plate or beryllium compound refractive lens. The recovered probe from each optic is back propagated in order to plot the beam caustic and determine the precise focal size and position. The power distribution of the reconstructed probe modes also allows the quantification of the beams coherence and is compared with the values predicted by a Gaussian–Schell model and the optics exit intensity.

31 July 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
VDVishal Dhamgaye
Vishal Dhamgaye
DLDavid Laundy
David Laundy
HKHossein Khosroabadi
Hossein Khosroabadi
TMThomas Moxham
Thomas Moxham
SBSara Baldock
Sara Baldock
Kawal SawhneyKawal Sawhney
Kawal Sawhney
Visible light optical elements such as lenses and mirrors have counterparts for X-rays. In the visible regime, a variable focusing power can be achieved by an Alvarez lens which consists of a pair of inline planar refractors with a cubic thickness profile. When the two refractors are laterally displaced in opposite directions, the parabolic component of the wavefront is changed resulting in a longitudinal displacement of the focus. This paper reports an implementation of this concept for X-rays using two planar microfabricated refractive elements. The Alvarez X-ray lens can vary the focal distance of an elliptical X-ray mirror or a planar compound X-ray lens over several millimetres. The study presents the first demonstration of an Alvarez X-ray lens which adaptively corrects defocus and astigmatism aberrations of X-ray optics. In addition, the Alvarez X-ray lens eliminates coma aberration in an elliptical mirror, to the lowest order, when combining the lens with an adjustment of the pitch angle of the mirror.

28 October 2024 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
XTXujie Tong
Xujie Tong
VDVishal Dhamgaye
Vishal Dhamgaye
QCQiucheng Chen
Qiucheng Chen
QWQingxin Wu
Qingxin Wu
BDBiao Deng
Biao Deng
Kawal SawhneyKawal Sawhney
Kawal Sawhney
Hard X-ray microscopes with 20–30 nm spatial resolution ranges are an advanced tool for the inspection of materials at the nanoscale. However, the limited efficiency of the focusing optics, for example, a Fresnel zone plate (ZP) lens, can significantly reduce the power of a nanoprobe. Despite several reports on ZP lenses that focus hard X-rays with 20 nm resolution – mainly constructed by zone-doubling techniques – a systematic investigation into the limiting factors has not been reported. We report the structural effects on the focusing and imaging efficiency of 20–30 nm-resolution ZPs, employing a modified beam-propagation method. The zone width and the duty cycle (zone width/ring pitch) were optimized to achieve maximum efficiency, and a comparative analysis of the zone materials was conducted. The optimized zone structures were used in the fabrication of Pt-hydrogen silsesquioxane (HSQ) ZPs. The highest focusing efficiency of the Pt-HSQ-ZP with a resolution of 30 nm was 10% at 7 keV and >5% in the range 6–10 keV, whereas the highest efficiency of the Pt-HSQ-ZP with a resolution of 20 nm was realized at 7 keV with an efficiency of 7.6%. Optical characterization conducted at X-ray beamlines demonstrated significant enhancement of the focusing and imaging efficiency in a broader range of hard X-rays from 5 keV to 10 keV, demonstrating the potential application in hard X-ray focusing and imaging.