Multiphase machines have been attracting more and more attentions in high-reliability-required applications due to their inherent fault-tolerant capability. Postfault control strategies with-standing open-circuit faults (OCFs) for several multiphase machine types, like five-phase, symmetrical six-phase (S6) and asymmetrical six-phase (A6) machines, have been widely investigated in recent literatures. However, fault-tolerant control for symmetrical dual three-phase (D3) machines have rarely been studied so far. To fill the gap, this paper addresses key issues in postfault decoupling modeling and field orient control (FOC) for the dual three-phase surface-mounted permanent magnet synchronous machine (SPMSM) with isolated neutrals under single-phase OCF. To do so, a postfault decoupling model with reduced-order transformation is established for D3 machines. Postfault current references are reconfigured with two main-stream criteria: minimum-loss (ML) and maximum-torque (MT). Furthermore, third harmonic flux linkage/back-EMF are taken into account in modeling and control, since it causes third harmonic currents and hence torque ripples under single-phase OCF. Proportional-resonant controllers are employed to decrease the third harmonic currents and torque pulsations. The validity of the postfault control strategies is proved by experiments.
24 October 2017 in IEEE Transactions on Energy Conversion
Large torque and voltage ripple are inherent drawbacks of doubly salient generators. This paper firstly introduces torque sharing function (TSF) into the application of a dual-channel three-phase 12/8 poles doubly salient permanent magnet generator (DSPMG) to reduce torque and voltage ripple. Based on the principle of copper losses minimization, a new TSF is proposed through theoretical analysis and numerical computation. The proposed TSF is compared to conventional TSFs according to three evaluation criteria. In order to achieve satisfying and consistent steady state and dynamic performances over the whole operation range, gain scheduling PI controller is adopted to overcome the highly nonlinear characteristic of the DSPMG. Besides, with compensators of back-EMF, cogging torque and losses adopted as feed-forward, a dual closed-loop generation control system is detailed designed. Both simulation and experimental results verify the effectiveness of the proposed control system and the copper losses minimization TSF in reducing torque and voltage ripple.
Passive reconstruction methods such as traditional multi-view stereo are capable to accurate reconstruction results. However, the depth calculation of multi-view stereo encounters significant difficulties, especially when the corresponding points have some degree of inaccuracy or unreliability. In this paper, we make use of geometric and shading cues information in the multi-view stereo approach to construct a robust energy function, which is also effective to optimize the depth information provided by multi-view stereo. This work improves the accuracy of point cloud depth. we evaluated our algorithm in the famous DTU datasets, and established our own dinosaur datasets. All the data is collected by mobile devices under natural light condition, while the reconstruction results are completed and accurate.
1 April 2018 in International Journal of Hydrogen Energy
As one of the most widespread faults in permanent magnet synchronous motors (PMSM), demagnetization faults can dramatically degrade the performance of the motor system. Extensive research has been conducted on partial demagnetization faults in existing literature, providing the harmonic range of the back electromotive force (EMF) when demagnetization faults occur. In order to enhance the specificity of fault characteristics in practical application scenarios, this paper analyzes the characteristic faulty signature associated with motor topologies in the back EMF and currents for fractional slot PMSMs experiencing partial demagnetization faults. The back EMF reduction model under faulty conditions is constructed. An analysis is conducted on the specific faulty harmonic components of PMSMs with three distinct pole-slot combinations, using the dq-axis reference frame. The research reveals that in concentrated winding fractional slot PMSMs, the specific harmonic order of partial demagnetization fault in the dq-axis is determined by the ratio of the number of slots to the number of pole pairs. The effectiveness of the proposed conclusion is validated by finite element (FE) simulation and experiment results.