Jingjing Yang

Jingjing Yang

Auto-generated profile, based on publicly available information

Jingjing Yang

Shandong University

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in High Voltage
Verified
Journal Article
Open access
ZKZhaoyang Kang
Zhaoyang Kang
Fuqiang RenFuqiang Ren
Fuqiang Ren
HZHongru Zhang
Hongru Zhang
JYJingjing Yang
Jingjing Yang
KHKaining Hou
Kaining Hou
HWHuaxin Wen
Huaxin Wen
Basin‐type insulator often has small cracks due to stress concentration. The current method cannot accurately reflect the stress condition of the insulator to find the stress concentration areas. To solve these problems, a method for detecting two‐dimensional plane stress ( δ 1 and δ 2 ) within different depth ranges in a basin‐type insulator is proposed based on critically refracted longitudinal (LCR) wave. First, the acoustoelastic equation characterising the relationship between the variation of LCR wave propagation time and the plane stress was derived. Next, the propagation characteristics of LCR wave in epoxy resin samples were investigated. Then, the stress distribution within different depth ranges of the insulator subjected to hydraulic load was measured using the proposed method, including direction ( θ ), δ 1 and δ 2 . The results show that the magnitude of the stress alone cannot accurately characterise the stress state. Points with equal distances to the centre have similar stress magnitudes, but their directions are not the same. With increasing depth, θ remains essentially unchanged at the same location, while δ 1 and δ 2 decrease, and the rate of decrease varies at different locations. Comparing the measured and simulated data, the results showed that they were in good agreement, and the maximum errors of stress value and θ were 0.69 MPa and 2.97°, respectively, which confirmed the feasibility and accuracy of the stress detection in the proposed method.

27 September 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
HWHongbin Wu
Hongbin Wu
Hongshun LiuHongshun Liu
Hongshun Liu
ZXZhitong Xue
Zhitong Xue
JYJingjing Yang
Jingjing Yang
QLQing-quan Li
Qing-quan Li
WSWah Hoon Siew
Wah Hoon Siew
Bubbles in transformer oil can easily lead to partial discharge, which can deteriorate the transformer oil and even breakdown the transformer insulation. To clarify the migration process and the characteristics of bubbles generated in an oil-immersed power transformer exposed to an extremely uneven electric field, we experimentally monitor these phenomena under an extremely nonuniform AC electric field and numerically simulate the migration distance and the migration speed of bubbles with different initial positions and sizes. The results show that the streamer discharge channel formed by a partial discharge in oil is gasified into a bubble channel. After it collides with the surface of the pressboard, its morphology is transformed into approximately spherical bubbles due to the surface tension of the gas-liquid interface. After bubbles are generated in the oil, they move away from areas with a strong electric field due to the electric-field force and gradually approach the oil surface due to the buoyancy force. The experimental results are consistent with the simulation results, which verify the rationality of the simulation model.

15 September 2025 in High Voltage
Verified
Journal Article
Open access
JYJingjing Yang
Jingjing Yang
KHKaining Hou
Kaining Hou
HWHongbin Wu
Hongbin Wu
PGPenghong Guo
Penghong Guo
YXYongwei Xv
Yongwei Xv
QLQing-quan Li
Qing-quan Li
Converter transformers are the core components of ultra‐high voltage (UHV) transmission systems. The main cause of faults in converter transformers is irreversible deterioration of oil–pressboard insulation under combined electrical–thermal–mechanical stress over long operating times. In this paper, the chemical characteristics of oil–pressboard insulation samples subjected to electrical–thermal–mechanical ageing for different times are studied. An image processing algorithm is used to analyse the discharge propagation characteristics of the samples under combined alternating current (AC)–direct current (DC) voltage, and the current pulse curves and phase resolved partial discharge spectrogram corresponding to the discharge images are analysed. An improved wavelet packet algorithm is used to denoise the discharge current pulse. Finally, the influence of electrical–thermal–mechanical ageing on discharge characteristics is analysed using radar charts. The condition of oil–pressboard insulation is one of the main factors determining the life expectancy of converter transformers. The results obtained here therefore have practical significance for understanding the process of insulation failure caused by accelerated ageing of oil–pressboard insulation.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
JYJingjing Yang
Jingjing Yang
KHKaining Hou
Kaining Hou
ZKZhaoyang Kang
Zhaoyang Kang
Hongshun LiuHongshun Liu
Hongshun Liu
QLQing-quan Li
Qing-quan Li
For extremely large ultra-high-voltage (UHV) power transmission and distribution lines using hybrid reactive power compensation (HRPC), single-phase earth fault (1LG), three-phase ground fault (3LG), phase-to-phase fault (2LS), and two-phase grounding fault (2LG) often occurs. This study uses numerical emulations to examine the indicators of the interruption performance for the circuit breaker in case of different faults. Based on the equivalent-valued parameter circuit and the structure of a UHV demonstration project, formal expressions for the interruption performance of the circuit breaker are deduced, and the influence of such factors as the location of the fault and the degree of HRPC on the interruption performance of the 1LG, 2LG, 3LG, and 2LS is analyzed. Finally, the interruption performance of circuit breakers under different faults are compared. A quantitative evaluation of the influence of changes in the relevant indicators on the interruption performance of circuit breakers can provide a technical basis for choosing the appropriate design of the circuit breaker in light of the application as well as equipment development and assessment.

8 January 2025
Verified
Book Chapter
Closed access
PDF file
JYJingjing Yang
Jingjing Yang
FRFuqiang Ren
Fuqiang Ren
RYRenyi Yang
Renyi Yang
YXYongwei Xv
Yongwei Xv
GGGuodong Gu
Guodong Gu
QLQing-quan Li
Qing-quan Li