Jiawen Zhao

Jiawen Zhao

Auto-generated profile, based on publicly available information

Jiawen Zhao

Columbia University Mailman School of Public Health New York New York USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2024 in Journal of Nursing Scholarship
Verified
Journal Article
Closed access
ANAllison A. Norful
Allison A. Norful
MAMonirah Albloushi
Monirah Albloushi
JZJiawen Zhao
Jiawen Zhao
YGYuandi Gao
Yuandi Gao
JCJanelle Castro
Janelle Castro
RRReynaldo R. Rivera
Reynaldo R. Rivera

16 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CSChunguang Suo
Chunguang Suo
JZJiawen Zhao
Jiawen Zhao
WZWenbin Zhang
Wenbin Zhang
PLPeng Li
Peng Li
RHRujin Huang
Rujin Huang
XTXiangyu Tan
Xiangyu Tan
The tracking and positioning of transmission lines is a key element for UAVs (Unmanned Aerial Vehicles) to achieve autonomous inspection of transmission lines. Current methods are vulnerable to weather and environmental factors, have high costs, and have difficulties in data processing. Therefore, this paper proposes a transmission line tracking and localization method based on the electric field sensor array, which calculates the current UAV’s heading angle deflection angle, the distance between the transmission line and the UAV, and the elevation angle, providing a new idea to solve the problem of UAV inspection of transmission lines. At the same time, the electric field distribution of different arrangements of three-phase transmission lines was analyzed using COMSOL to determine the flight area of the UAV. By comparing the electric field distribution of the UAV flight area and single-phase transmission lines, it was verified that the current method is also applicable in the three-phase transmission line scenario, and it was further verified that the sensor array used can sense the change of the UAV position in the flight area, indicating that the electric field sensor array can realize the transmission line tracking and localization of transmission lines. The experimental results showed that, in the three-phase transmission line scenario, when the sensor array moves along the transmission straight wire, the maximum absolute error of the heading angle deflection angle calculated according to this method was 8.2°, the maximum absolute error of the distance between the array and the transmission line was 19.3 cm, and the maximum absolute error of the elevation angle was 11.37°; the error was within a reasonable range and can be used for the UAV to realize autonomous inspection.

12 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
WZWenbin Zhang
Wenbin Zhang
PLPeng Li
Peng Li
NZNianrong Zhou
Nianrong Zhou
CSChunguang Suo
Chunguang Suo
WCWeiren Chen
Weiren Chen
Yincheng LiYincheng Li
Yincheng Li
The traditional method of using electric field sensors to realize early warning of electric power safety distance cannot measure the distance of dangerous sources. Therefore, aiming at the electric field with a frequency of 50 to 60 Hz (AC electric field), a new method for localization of aerial AC target by the capacitive one-dimensional spherical electric field sensor circular array is studied. This method can directly calculate the distance, elevation, and azimuth of the detector from the dangerous source. By combining the measurement principle of the spherical electric field sensor and the plane circular array theory, a mathematical model for the localization of aerial targets in an AC electric field is established. An error model was established using Gaussian noise and the effects of different layout parameters on the localization error were simulated. Based on mutual interference between sensors, minimum induced charge, and localization error, an optimal model for sensor layout was established, and it was solved by using genetic algorithms. The optimization results show that when the number of sensors is 4, the array radius is 20 cm, and the sensor radius is 1.5 cm, the ranging error is 8.4%. The detector was developed based on the layout parameters obtained from the optimization results, and the localization method was experimentally verified at 10 and 35 kV alarm distances. The experimental results show that when the detector is located at 10 kV alarm distance, the distance error is 0.18 m, the elevation error is 6.8°, and the azimuth error is 4.57°, and when it is located at 35 kV alarm distance, the distance error is 0.2 m, the elevation error is 4.8°, and the azimuth error is 5.14°, which meets the safety distance warning requirements of 10 and 35 kV voltage levels.