Matteo Moratti

Matteo Moratti

Auto-generated profile, based on publicly available information

Matteo Moratti

Studio Calvi Pavia, 27100 Pavia, Italy

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
PDF file
Daniele MalomoDaniele Malomo
Daniele Malomo
Nicola ScattarreggiaNicola Scattarreggia
Nicola Scattarreggia
AOAndrea Orgnoni
Andrea Orgnoni
RPRui Pinho
Rui Pinho
MMMatteo Moratti
Matteo Moratti
GCGian Michele Calvi
Gian Michele Calvi
An innovative discontinuum-based micromodeling approach, the Applied Element Method, is used in this work to investigate explicitly potential failure mechanisms that might have contributed to the collapse of the Morandi Bridge in Genoa, Italy, which occurred on August 14, 2018. While, consistently with the findings presented in a previous contribution by the same authors, the initial trigger of the collapse mechanism was assumed as the release of one of the stays, this study investigates, through a sensitivity study, the impact that several parameters and epistemic uncertainties, including reduction of cables’ cross section (potentially induced by corrosion) and various possible configurations of both passive and active reinforcements in the main deck, have on the predicted failure mode. Then, to indicate the structural elements and details in which a potential presence of corrosion should be more carefully explored, the observed debris distribution is compared with its numerical counterparts.

1 November 2016 in Earthquake Spectra
Verified
Journal Article
Closed access
Paolo Martino CalviPaolo Martino Calvi
Paolo Martino Calvi
MMMatteo Moratti
Matteo Moratti
GCGian Michele Calvi
Gian Michele Calvi
Base isolators are effective tools to favor a high level of building performance under lateral load, providing protection to both structural and nonstructural elements. In this context, this paper discusses the possibility of employing materials with different frictional properties to enhance the response of flat and curved‐surface base isolators. Two innovative devices, referred to as “BowTie” and “BowC,” are introduced and discussed in some detail. A series of nonlinear time history analyses are then conducted using a customized computer program and considering a number of case study structures, designed applying a displacement‐based approach. The results of the analyses are used to discuss the key differences between variable friction and constant friction sliding isolation devices. It is shown that the newly proposed isolators may represent an improvement on classic base‐isolation solutions, in light of their higher energy absorption capacity, which contributes to significantly enhance their performance.

5 June 2022 in Engineering Structures
Verified
Journal Article
Closed access
Nicola ScattarreggiaNicola Scattarreggia
Nicola Scattarreggia
WGWilliam Galik
William Galik
PCPaolo M. Calvi
Paolo M. Calvi
MMMatteo Moratti
Matteo Moratti
AOAndrea Orgnoni
Andrea Orgnoni
RPRui Pinho
Rui Pinho

22 July 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Roberto NascimbeneRoberto Nascimbene
Roberto Nascimbene
EFEttore Fagà
Ettore Fagà
MMMatteo Moratti
Matteo Moratti
The prevalence of elevated reinforced concrete tanks is widespread across Italian water distribution networks, particularly in flat or low-relief areas. Primarily constructed by the late 1970s, these tanks often suffer from outdated hydraulic efficiency, unable to cope with the increasing urban water demands. With rising construction costs, the economic advantage has shifted toward underground tanks, leading to the decommissioning of many elevated tanks. Despite being obsolete, elevated tanks from the 1960s and 1970s still stand in densely urbanized regions. However, demolishing them may prove less cost-effective than retrofitting to restore their original structural capacity. The widespread presence of these structures, coupled with their susceptibility to decay from weathering and poor maintenance, necessitates a comprehensive assessment of their resilience against gravitational and lateral forces, including seismic activity. Consequently, there is a pressing need to develop an analysis and verification methodology, particularly focused on seismic resilience, tailored to existing elevated tanks. These structures, distinct from conventional reinforced concrete frames, are primarily designed to withstand vertical forces, emphasizing the importance of optimizing material usage in their retrofitting efforts.

3 July 2023 in Structures
Verified
Journal Article
Open access
RPRui Pinho
Rui Pinho
Nicola ScattarreggiaNicola Scattarreggia
Nicola Scattarreggia
AOAndrea Orgnoni
Andrea Orgnoni
SLSimone Lenzo
Simone Lenzo
GGGiulia Grecchi
Giulia Grecchi
GCGian Michele Calvi
Gian Michele Calvi

1 June 2019 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
MMMatteo Moratti
Matteo Moratti
FGFederica Gaia
Federica Gaia
SMSara Martini
Sara Martini
CTChrysanthi Tsioli
Chrysanthi Tsioli
GGGiulia Grecchi
Giulia Grecchi
GPGiorgio Proestos
Giorgio Proestos