Weimin Wang

Weimin Wang

Auto-generated profile, based on publicly available information

Weimin Wang

School of Electronics, Peking University, Beijing, 100871, China; Institute of Biomedical Engineering, Peking University Shenzhen Graduate School, Shenzhen, 518055, China; Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, 518132, China

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2018 in Applied Magnetic Resonance
Verified
Journal Article
Closed access
PDF file
FTFei Tian
Fei Tian
WWWeimin Wang
Weimin Wang
NLNaigui Liu
Naigui Liu
JJJiaqi Jiang
Jiaqi Jiang
CNCongkai Niu
Congkai Niu
YLYaxi Li
Yaxi Li

1 November 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
PWPengfei Wu
Pengfei Wu
YWYaohui Wang
Yaohui Wang
WWWenchen Wang
Wenchen Wang
WWWeimin Wang
Weimin Wang
JLJinhao Liu
Jinhao Liu
FLFeng Liu
Feng Liu
Passive shimming is widely used in magnetic resonance imaging (MRI) systems due to its excellent efficacy and cost-effectiveness. However, conventional shim tray structures have difficulty in effectively adjusting magnetic field distributions under specific conditions. This limitation can lead to insufficient cancellation of harmonics and result in significant residual forces on the trays, impeding accurate placement of the trays. In this study, instead of using the conventional design of the shim tray slot, we propose a dedicated passive shimming tray tailored for 3T cryogen-free animal MRI superconducting magnets. Passive shimming experiments were conducted to evaluate the performance of this novel design, in which we were able to improve the peak-to-peak magnetic field homogeneity within the 180 mm diameter imaging region, reducing peak-to-peak (p–p) variation from 349.35 ppm to 19.08 ppm. Furthermore, the p–p homogeneity of the magnetic field measured at the imaging area with a diameter of spherical volume (DSV) of 160 mm reached 8.67 ppm. In addition, we strictly controlled the residual magnetic force of the shim tray to ensure its accurate placement. The experimental results indicate that the proposed structural optimization method and the residual magnetic force control strategy show potential in high-field MRI instruments requiring high homogeneity and handling of high residual magnetic force.

25 March 2022 in Frontiers in Public Health
Verified
Journal Article
Open access
Yu ChenYu Chen
Yu Chen
QLQiao Liu
Qiao Liu
WWWeimin Wang
Weimin Wang
AXAna Xie
Ana Xie
Jue LiuJue Liu
Jue Liu
Background: Professional identity (PI) influences the doctor's thoughts and behaviors. Thus, PI formation (PIF) plays an important role in medical students' education. Major changes to the learning environment could impact PIF, but the influence of the novel coronavirus disease 2019 (COVID-19) pandemic on medical students' PI had confusing conclusions in previous studies. We aimed to compare PI of medical students by using the data from three waves of national cross-sectional surveys conducted in China in 2019, 2020, and 2021, and to examine factors that influence PIF.Method: We used data from the China Medical Student Survey (CMSS) which has conducted three national cross-sectional surveys. From 2019 to 2021, CMCC retrieved data on PI from a nationally representative sample of medical students from 33, 121, and 123 colleges, respectively. We analyzed the data using Chi-square test, analysis of variance, and multivariable logistic regression according to sociodemographic characteristics, pre-university experience, college characteristics, and college experience.Results: A total of 244,040 medical students in China participated in the surveys. The overall score of PI increased from 3.80 in 2019 to 3.85 in 2021. Medical students with family medical background, high intrinsic and extrinsic motivation of major selection, teachers' positive role model, and high personal comprehensive quality ranking were more likely to have higher PI (all p < 0.05). The more attention students paid to the COVID-19 pandemic, the higher PI they would have (aOR 1.93, 95% CI 1.67–2.24 for more attention; aOR 2.31, 95% CI 2.00–2.68 for the most attention). However, parents' participation on the front lines of COVID-19 pandemic negatively influenced the PI of medical students (aOR 0.72, 95% CI 0.57–0.93).Conclusions: PI of medical students increased during the COVID-19 pandemic. The impact of the pandemic on PI was complex. To improve the PI of medical students, the education sector, health sector and the society need to make concerted efforts.

1 February 2024 in Magnetic Resonance Letters
Verified
Journal Article
Open access
YWYaohui Wang
Yaohui Wang
WWWeimin Wang
Weimin Wang
HLHui Liu
Hui Liu
SCShunzhong Chen
Shunzhong Chen
FLFeng Liu
Feng Liu
Qiuliang WangQiuliang Wang
Qiuliang Wang
The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging (MRI) magnets requires the careful management of exogenous heat sources. A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems. In this study, we present an enhanced shielding method incorporating a regionalized stray field constraining strategy. By optimizing the constraint parameters, we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half. In real measurement in an integrated MRI system, the developed gradient assembly demonstrated good performance and supported to output images of excellent quality. Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets.

9 October 2024 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
JLJinhao Liu
Jinhao Liu
YWYaohui Wang
Yaohui Wang
MWMiutian Wang
Miutian Wang
WWWenchen Wang
Wenchen Wang
GYGang Yang
Gang Yang
FLFeng Liu
Feng Liu

25 December 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YWYaohui Wang
Yaohui Wang
HLHui Liu
Hui Liu
SCShunzhong Chen
Shunzhong Chen
WWWeimin Wang
Weimin Wang
FLFeng Liu
Feng Liu
Qiuliang WangQiuliang Wang
Qiuliang Wang
As an essential system component of a magnetic resonance imaging (MRI) instrument, the magnet offers strong and uniform magnetic field intensity, which is critical for achieving the desired image resolution. This work presents the design, fabrication, and measurement of a 3 T cryogen-free superconducting magnet for animal MRI applications. The magnet presented excellent stability, maintaining a field variation of just 0.01 ppm per hour at full strength. After passive shimming, the magnetic field homogeneity achieved around 32 ppm over an imaging sphere with a diameter of 160 mm. The success of this reliable magnet technology paves the way for its adoption in future whole-body human MRI systems.