19 February 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
Time resolution in time-of-flight positron emission tomography (TOF-PET) has improved significantly over the last decade due to advancements in scintillation materials, photodetectors, and readout electronics, which has increased the signal-to-noise ratio (SNR) compared to conventional PET. Silicon photomultipliers (SiPMs) in TOF-PET detectors are often operated at high bias voltage to improve the time performance at the expense of increasing signal noise. SiPM noise, both correlated and uncorrelated, can cause baseline fluctuations, leading to time-walk effects when a leading edge trigger strategy is used, and thus limiting timing performance. We examined the effect of SiPM baseline fluctuations using the FastIC ASIC, a scalable multichannel readout for fast timing applications. We flagged noisy events by using a comparator signal triggered by dark counts before the actual scintillation event. We tested different classification and correction methods with scintillating crystals and Cherenkov radiators, coupled to analog SiPMs from Broadcom (NUV-MT) and Hamamatsu Photonics. We reduced the coincidence time resolution (CTR) in bismuth germanate 2x2x3 mm3 (BGO) crystals from 410 ± 10 ps to 388 ± 10 ps FWHM (5 %) by correcting the time-walk on the noisy events. We measured an improvement from 107 ±2 ps to 93.5 ± 0.6 ps (11 %) for LYSO 2x2x3 mm3 crystals by filtering the noisy events. An improvement of 9 % on the CTR of the EJ232 plastic scintillator was also achieved by filtering noisy events, reducing it from 82.2 ± 0.5 ps to 75 ± 1 ps. This study presents a scalable method for flagging undesired events in a full TOF-PET system and discusses the impact of SiPM noise on the FastIC readout.
26 May 2025 in EJNMMI Physics
EasyPET.3D is a preclinical positron emission tomography (PET) scanner with a unique scanning method based on two face-to-face detector modules with two axes of motion. Its performance evaluation is presented using the NEMA NU-4 standards and an animal model. Each detector module consists of a 32 × 2 pixelated cerium-doped lutetium-yttrium oxyorthosilicate (LYSO:Ce) scintillator array with individual crystals of 2.0 × 2.0 × 30 mm3. The crystal arrays are coupled to 1.3 × 1.3 mm2 silicon photomultipliers (SiPMs). The transaxial field-of-view (FoV) is adjustable up to 48 mm in diameter, and the axial length is 73 mm. The performance characterization includes spatial resolution, sensitivity, count rate, scatter fraction (SF), and image quality (IQ) measurements. Furthermore, mice experiments were conducted to evaluate the in vivo imaging capability. Spatial resolution at the FoV centre (CFoV) in radial, tangential, and axial directions was 0.98±0.08, 0.97±0.06 and 0.94±0.08 mm, respectively. An absolute sensitivity of 0.23% was measured at CFoV. The mouse-like phantom SF was 16% (913 cps at 18 MBq). Recovery coefficients in the IQ phantom varied from 21±34% to 85±50% (1 to 5 mm diameter rods, accordingly). The uniformity was 17.6%, and spill-over ratios for water-filled and air-filled chambers were 0.49 and 0.40, respectively. EasyPET.3D geometry favours the reduction of parallax error, despite its low sensitivity. The system linearity is suitable for the low range of activities (7–8 MBq) used for mice imaging. The overall performance showed that easyPET.3D has potential for entry-level preclinical applications.
14 March 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
EasyPET.3D is a preclinical positron emission tomography (PET) scanner using a unique scanning method based on two face-to-face detector modules with two axes of motion. The sensitivity and spatial resolution were optimized for mouse imaging by studying the operating parameters related to motor motion (speed and step angle), following the NEMA NU 4-2008 Standards. Moreover, the impact of the energy window and positron range on the images was assessed. The fan motor should operate at a speed of 20 full steps/s, while the fan (F = 0.014∘– 0.113∘) and axial (A = 0.9∘–9.0∘) step angles are chosen depending on the study’s purpose. The image quality experiment demonstrated the high-resolution capability of easyPET.3D. A 200–750 keV energy window maximized the sensitivity (+ 200%) without significantly increasing scatter fraction (SF) (+ 35%). In contrast, the acquisition protocol made it difficult to conclude about the positron range effect. The feature with the most impact on the scanner’s performance is the fan motor speed. A lower fan motor speed of 20 steps/s enhanced sensitivity and spatial resolution by + 122% and + 60%, respectively, increased noise equivalent count rate by 155%, decreased SF by 7%, and improved recovery coefficient by + 35%.
16 February 2026 in IEEE Transactions on Nuclear Science
Silicon Photomultipliers (SiPMs) have become an integral part of time-of-flight positron emission tomography (TOF-PET) scanners in recent years. Their excellent photodetection efficiency and fast decay time are essential in state-of-the-art timing resolutions, which have enabled improvements in image quality for TOF-PET. However, most SiPMs share a common architecture: an array of single avalanche photodiodes. This design has a limitation: each pixel requires its own quenching resistor and conductive connections, creating inactive regions that reduce the effective detection area. In this paper we explored a new type of SiPMs called the Micropixel Avalanche Photodiodes (MAPD) for the purposes of TOF-PET. These devices utilize buried pixel technology, which minimizes detector dead zones and achieves an almost 100 % fill factor. We evaluated their noise characteristics, energy resolution, and coincidence timing resolution (CTR). Our findings indicate that although the MAPD-3NM-II devices exhibit higher dark count rates, notable optical cross-talk, and a narrower overvoltage range compared to the reference Hamamatsu S14160-3015PS SiPMs, they offer superior energy resolution—improving up to 17 % at 511 keV—while maintaining competitive timing performance at the same overvoltage. In particular, with 3.8×3.8×4 mm3 LYSO crystals, the MAPD-3NM-II achieved a CTR of 336 ± 12 ps, a 5% improvement compared to Hamamatsu at the same overvoltage. Despite operating only up to 4.5 V, the MAPD-3NM-II demonstrates strong potential for TOF-PET applications, especially in scenarios prioritizing energy resolution. Further structural optimizations to reduce cross-talk and expand the operable voltage range could make this technology a competitive alternative to established SiPM architectures.
29 May 2026 in IEEE Transactions on Radiation and Plasma Medical Sciences
Photon-counting computed tomography (PCCT) using scintillator-based detectors are emerging as a promising technique for high-resolution, energy-resolved imaging in preclinical and clinical settings. The presented work describes the development and integration of a new computed tomography (CT) approach in easyPET.3D system, a dual-axis rotational micro-positron emission tomography (PET) system. The proposed CT methodology uses the same radiation detectors used for PET to detect photon emission from radioactive sources. To investigate the performance of this CT imaging approach, simulated and experimental data were collected to assess the system’s spatial resolution and material discrimination capabilities, using an 241Am. A PMMA and wire copper-based phantom was scanned using a fan-beam configuration. The obtained images were reconstructed using Filtered Back Projection (FBP). Reconstructed images from simulations and experimental prototype were visually and quantitatively similar. The system demonstrated the ability to detect submillimetre high-attenuation structures and differentiate materials with varying densities. Spatial resolution analysis, based on FWHM measurements of Gaussian fits, showed good agreement with physical dimensions. Improved tangential resolution was observed in experimental data when using finer angular steps enabled by the fan rotation step-motor. These results demonstrated the potential of reliable CT imaging using an 241Am source, the easyPET’s detectors and its rotation methodology. (Patent pending: WO 2025/158418 A1).