Regina Gapo Oliveira

Ms. Regina Gapo Oliveira

University of Aveiro, Aveiro, Portugal
+2
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RORegina Gapo Oliveira
Regina Gapo Oliveira
PCPedro Manuel Mendes Correia
Pedro Manuel Mendes Correia
ASAna Luísa M. Silva
Ana Luísa M. Silva
PEPedro Encarnação
Pedro Encarnação
FRFabiana M. Ribeiro
Fabiana M. Ribeiro
JVJoão Filipe Calapez De Albuquerque Veloso
João Filipe Calapez De Albuquerque Veloso
Monitoring the vital signs of mice is an essential practice during imaging procedures to avoid populational losses and improve image quality. For this purpose, a system based on a set of devices (piezoelectric sensor, optical module and thermistor) able to detect the heart rate, respiratory rate, body temperature and arterial blood oxygen saturation (SpO2) in mice anesthetized with sevoflurane was implemented. Results were validated by comparison with the reported literature on similar anesthetics. A new non-invasive electrocardiogram (ECG) module was developed, and its first results reflect the viability of its integration in the system. The sensors were strategically positioned on mice, and the signals were acquired through a custom-made printed circuit board during imaging procedures with a micro-PET (Positron Emission Tomography). For sevoflurane concentration of 1.5%, the average values obtained were: 388 bpm (beats/minute), 124 rpm (respirations/minute) and 88.9% for the heart rate, respiratory rate and SpO2, respectively. From the ECG information, the value obtained for the heart rate was around 352 bpm for injectable anesthesia. The results compare favorably to the ones established in the literature, proving the reliability of the proposed system. The ECG measurements show its potential for mice heart monitoring during imaging acquisitions and thus for integration into the developed system.

7 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JSJoana Simões
Joana Simões
RORegina Gapo Oliveira
Regina Gapo Oliveira
FCFlorinda M. Costa
Florinda M. Costa
António TeixeiraAntónio Teixeira
António Teixeira
Catia LeitaoCatia Leitao
Catia Leitao
ASAna Luísa M. Silva
Ana Luísa M. Silva
Invisible health monitoring is currently a topic of global interest within the scientific community. Sensorization of everyday objects can provide valuable health information without requiring any changes in people’s routines. In this work, a feasibility study of photoplethysmography (PPG) acquisition in the lower limbs for continuous and real-time monitoring of the vital signs, including heart rate (HR) and respiratory rate (RR), is presented. The proposed system uses two MAX30102 sensors to obtain PPG signals from the back of the thigh. As proof of concept, tests were conducted in 17 volunteers (age group between 22 and 40 years old, twelve females and five males), and the results were compared to those of reference sensors. A Pearson correlation coefficient of r = 0.92 and r = 0.77 and a mean difference of 1.2 bpm and 0.9 rpm for HR and RR, respectively, were obtained between the developed system and reference. System accuracies of 95.9% for HR and 91.3% for RR were achieved, showing the system viability for vital sign monitoring of the lower limbs.

26 May 2025 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
FRFabiana M. Ribeiro
Fabiana M. Ribeiro
PEPedro Encarnação
Pedro Encarnação
ASAna Luísa M. Silva
Ana Luísa M. Silva
PCPedro Manuel Mendes Correia
Pedro Manuel Mendes Correia
APAfonso X. Pinto
Afonso X. Pinto
JVJoão Filipe Calapez De Albuquerque Veloso
João Filipe Calapez De Albuquerque Veloso
EasyPET.3D is a preclinical positron emission tomography (PET) scanner with a unique scanning method based on two face-to-face detector modules with two axes of motion. Its performance evaluation is presented using the NEMA NU-4 standards and an animal model. Each detector module consists of a 32 × 2 pixelated cerium-doped lutetium-yttrium oxyorthosilicate (LYSO:Ce) scintillator array with individual crystals of 2.0 × 2.0 × 30 mm3. The crystal arrays are coupled to 1.3 × 1.3 mm2 silicon photomultipliers (SiPMs). The transaxial field-of-view (FoV) is adjustable up to 48 mm in diameter, and the axial length is 73 mm. The performance characterization includes spatial resolution, sensitivity, count rate, scatter fraction (SF), and image quality (IQ) measurements. Furthermore, mice experiments were conducted to evaluate the in vivo imaging capability. Spatial resolution at the FoV centre (CFoV) in radial, tangential, and axial directions was 0.98±0.08, 0.97±0.06 and 0.94±0.08 mm, respectively. An absolute sensitivity of 0.23% was measured at CFoV. The mouse-like phantom SF was 16% (913 cps at 18 MBq). Recovery coefficients in the IQ phantom varied from 21±34% to 85±50% (1 to 5 mm diameter rods, accordingly). The uniformity was 17.6%, and spill-over ratios for water-filled and air-filled chambers were 0.49 and 0.40, respectively. EasyPET.3D geometry favours the reduction of parallax error, despite its low sensitivity. The system linearity is suitable for the low range of activities (7–8 MBq) used for mice imaging. The overall performance showed that easyPET.3D has potential for entry-level preclinical applications.

29 April 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
RORegina Gapo Oliveira
Regina Gapo Oliveira
JSJoana Simões
Joana Simões
PCPedro Manuel Mendes Correia
Pedro Manuel Mendes Correia
António TeixeiraAntónio Teixeira
António Teixeira
FCFlorinda Costa
Florinda Costa
ASAna Luísa M. Silva
Ana Luísa M. Silva
The growing prevalence of chronic diseases, population aging, and the shift toward preventive and personalized care under Healthcare 5.0 have increased the need for continuous health monitoring beyond clinical settings. While wearable devices enable remote monitoring, their long-term use is often limited by user compliance, comfort issues, battery dependence, and disruption of daily routines. To address these limitations, unobtrusive home-based health monitoring systems have emerged, integrating sensing technologies into domestic environments and everyday objects. This review provides a system-level analysis of unobtrusive health monitoring technologies for smart homes. It examines seven major sensing approaches, including camera-, laser-, radar-, infrared-, mechanical-, bioelectrical-, and optical-based sensors, and their integration into four home environments: living areas, bathrooms, bedrooms, and home offices. For each sensing modality, the operating principles, monitored physiological parameters, representative applications, and key advantages and limitations are discussed. Overall, existing solutions reveal trade-offs among measurement accuracy, robustness in real home conditions, energy autonomy, privacy preservation, and user acceptance. Heart rate and respiratory rate are the most commonly monitored parameters, while multimodal and clinically validated systems remain limited. Although unobtrusive sensing technologies show strong potential for proactive and personalized healthcare, challenges related to accuracy, interoperability, privacy, and cost continue to hinder large-scale adoption.

29 May 2026 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
RORegina Gapo Oliveira
Regina Gapo Oliveira
PEPedro Encarnação
Pedro Encarnação
APA. X. Pinto
A. X. Pinto
ASAna Luísa M. Silva
Ana Luísa M. Silva
PCPedro Manuel Mendes Correia
Pedro Manuel Mendes Correia
JVJoão Filipe Calapez De Albuquerque Veloso
João Filipe Calapez De Albuquerque Veloso
Photon-counting computed tomography (PCCT) using scintillator-based detectors are emerging as a promising technique for high-resolution, energy-resolved imaging in preclinical and clinical settings. The presented work describes the development and integration of a new computed tomography (CT) approach in easyPET.3D system, a dual-axis rotational micro-positron emission tomography (PET) system. The proposed CT methodology uses the same radiation detectors used for PET to detect photon emission from radioactive sources. To investigate the performance of this CT imaging approach, simulated and experimental data were collected to assess the system’s spatial resolution and material discrimination capabilities, using an 241Am. A PMMA and wire copper-based phantom was scanned using a fan-beam configuration. The obtained images were reconstructed using Filtered Back Projection (FBP). Reconstructed images from simulations and experimental prototype were visually and quantitatively similar. The system demonstrated the ability to detect submillimetre high-attenuation structures and differentiate materials with varying densities. Spatial resolution analysis, based on FWHM measurements of Gaussian fits, showed good agreement with physical dimensions. Improved tangential resolution was observed in experimental data when using finer angular steps enabled by the fan rotation step-motor. These results demonstrated the potential of reliable CT imaging using an 241Am source, the easyPET’s detectors and its rotation methodology. (Patent pending: WO 2025/158418 A1).