Recent citations Experimental ion mobility measurements in Ne-CF 4 D.J.G. Marques et al-Ion mobility measurements in Ar-CO2, Ne-CO2, and Ne-CO2-N2 mixtures, and the effect of water contents Alexander Deisting et al-Experimental ion mobility measurements in Ar-N 2 M.A.
Monitoring the vital signs of mice is an essential practice during imaging procedures to avoid populational losses and improve image quality. For this purpose, a system based on a set of devices (piezoelectric sensor, optical module and thermistor) able to detect the heart rate, respiratory rate, body temperature and arterial blood oxygen saturation () in mice anesthetized with sevoflurane was implemented. Results were validated by comparison with the reported literature on similar anesthetics. A new non-invasive electrocardiogram (ECG) module was developed, and its first results reflect the viability of its integration in the system. The sensors were strategically positioned on mice, and the signals were acquired through a custom-made printed circuit board during imaging procedures with a micro-PET (Positron Emission Tomography). For sevoflurane concentration of 1.5%, the average values obtained were: 388 bpm (beats/minute), 124 rpm (respirations/minute) and 88.9% for the heart rate, respiratory rate and , respectively. From the ECG information, the value obtained for the heart rate was around 352 bpm for injectable anesthesia. The results compare favorably to the ones established in the literature, proving the reliability of the proposed system. The ECG measurements show its potential for mice heart monitoring during imaging acquisitions and thus for integration into the developed system.
In this paper we present experimental results for ion reduced mobilities (K0) in gaseous trimethylamine, TMA—(CH3)3N, and xenon-TMA mixtures for reduced electric fields E/N between 7.5 and 60 Td and in the pressure range from 0.5 to 10 Torr, at room temperature. Both in the mixtures and in pure TMA only one peak was observed in the time of arrival spectra, which is believed to be due to two TMA ions with similar mass, (CH3)3N+ (59 u) and (CH3)2CH2N+ (58 u), whose mobility is indistinguishable in our experimental system. The possibility of ion cluster formation is also discussed. In pure TMA, for the E/N range investigated, an average value of 0.56 cm2V−1s−1 was obtained for the reduced mobility of TMA ions. For the studied mixtures, it was observed that even a very small amount of gaseous TMA (~0.2%) in xenon leads to the production of the above referred TMA ions or clusters. The reduced mobility value of this ion or ions in Xe-TMA mixtures is higher than the value in pure TMA: around 0.8 cm2V−1s−1 for TMA concentrations from 0.2% to about 10%, decreasing for higher TMA percentages, eventually converging to the reduced mobility value in pure TMA.
Data on ion mobility is important to improve the performance of large volume gaseous detectors, such as the ALICE TPC or in the NEXT experiment. In the present work the method, experimental setup and results for the ion mobility measurements in Ne-N2 mixtures are presented. The results for this mixture show the presence of two peaks for different gas ratios of Ne-N2, low reduced electric fields, E/N, 10–20 Td (2.4–4.8 kV cm−1 bar−1), low pressures 6–8 Torr (8–10.6 mbar) and at room temperature.
EasyPET.3D is a preclinical positron emission tomography (PET) scanner with a unique scanning method based on two face-to-face detector modules with two axes of motion. Its performance evaluation is presented using the NEMA NU-4 standards and an animal model. Each detector module consists of a 32 × 2 pixelated cerium-doped lutetium-yttrium oxyorthosilicate (LYSO:Ce) scintillator array with individual crystals of 2.0 × 2.0 × 30 mm3. The crystal arrays are coupled to 1.3 × 1.3 mm2 silicon photomultipliers (SiPMs). The transaxial field-of-view (FoV) is adjustable up to 48 mm in diameter, and the axial length is 73 mm. The performance characterization includes spatial resolution, sensitivity, count rate, scatter fraction (SF), and image quality (IQ) measurements. Furthermore, mice experiments were conducted to evaluate the in vivo imaging capability. Spatial resolution at the FoV centre (CFoV) in radial, tangential, and axial directions was 0.98±0.08, 0.97±0.06 and 0.94±0.08 mm, respectively. An absolute sensitivity of 0.23% was measured at CFoV. The mouse-like phantom SF was 16% (913 cps at 18 MBq). Recovery coefficients in the IQ phantom varied from 21±34% to 85±50% (1 to 5 mm diameter rods, accordingly). The uniformity was 17.6%, and spill-over ratios for water-filled and air-filled chambers were 0.49 and 0.40, respectively. EasyPET.3D geometry favours the reduction of parallax error, despite its low sensitivity. The system linearity is suitable for the low range of activities (7–8 MBq) used for mice imaging. The overall performance showed that easyPET.3D has potential for entry-level preclinical applications.
14 March 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
EasyPET.3D is a preclinical positron emission tomography (PET) scanner using a unique scanning method based on two face-to-face detector modules with two axes of motion. The sensitivity and spatial resolution were optimized for mouse imaging by studying the operating parameters related to motor motion (speed and step angle), following the NEMA NU 4-2008 Standards. Moreover, the impact of the energy window and positron range on the images was assessed. The fan motor should operate at a speed of 20 full steps/s, while the fan (F = 0.014∘– 0.113∘) and axial (A = 0.9∘–9.0∘) step angles are chosen depending on the study’s purpose. The image quality experiment demonstrated the high-resolution capability of easyPET.3D. A 200–750 keV energy window maximized the sensitivity (+ 200%) without significantly increasing scatter fraction (SF) (+ 35%). In contrast, the acquisition protocol made it difficult to conclude about the positron range effect. The feature with the most impact on the scanner’s performance is the fan motor speed. A lower fan motor speed of 20 steps/s enhanced sensitivity and spatial resolution by + 122% and + 60%, respectively, increased noise equivalent count rate by 155%, decreased SF by 7%, and improved recovery coefficient by + 35%.