Luca Novello

Luca Novello

Auto-generated profile, based on publicly available information

Luca Novello

Fusion for Energy, Garching, Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
KHKazuya Hamada
Kazuya Hamada
HMHaruyuki Murakami
Haruyuki Murakami
KTKatsuhiko Tsuchiya
Katsuhiko Tsuchiya
KKKatsumi Kawano
Katsumi Kawano
KFKazuma Fukui
Kazuma Fukui
ABAlessandro Bonito-Oliva
Alessandro Bonito-Oliva
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.

1 October 2015 in Fusion Engineering and Design
Verified
Journal Article
Closed access
LNLuca Novello
Luca Novello
OBOlivier Baulaigue
Olivier Baulaigue
ACAlberto Coletti
Alberto Coletti
NDNicolas Dumas
Nicolas Dumas
AFAlberto Ferro
Alberto Ferro
PZPietro Zito
Pietro Zito

25 February 2025 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LZL. Zani
L. Zani
QCQ. Le Coz
Q. Le Coz
KHK. Hamada
K. Hamada
MPM. Parody-Guzman
M. Parody-Guzman
BLB. Lacroix
B. Lacroix
LNL. Novello
L. Novello
In the framework of international development on fusion devices, the tokamak JT-60SA was equipped with superconducting magnets within a Europe-Japan collaboration. After a first integrated commissioning (IC) in 2021, another IC was conducted in 2023 reaching magnet energization levels compliant with 1 MA-class plasmas. The Toroidal Field (TF) coil system was loaded at nominal current and the Poloidal Field (PF) at 50% of nominal current. In the 2023 IC various energization pulse patterns were applied on PF coils to gain experience on the magnets control and protection system in operation conditions. Some tailored current pulses were applied to learn about PF coils coupling parameters and protection system, which sensitivity was found to be improved. In this environment, we developed tools and methods to model and predict the magnets behaviour to possibly identify coils limits in operation conditions. First step is with thermo-hydraulic evaluation of PF coil temperature safety margin evaluation along their pulsed current patterns. Second step is a first order analysis of the TF quench detection system sensitivity, found higher than expected to PF transients, and the contribution to possible mitigation measures to avoid spurious false positive detections. Both steps were benchmarked against experimental data collected during 2023 IC to consolidate models prediction capacities. Foreseen applications aim at checking plasma scenarios repetability rate or avoiding pulsed coil current to generate apparent fault signal in absence of real risk (mostly quench). The tools and methods are described and their rationales explained, together with their intrinsic limits and room for improvement.

21 November 2025 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LZL. Zani
L. Zani
TFT. Françonnet
T. Françonnet
BLB. Lacroix
B. Lacroix
QCQ. Le Coz
Q. Le Coz
SSS. Sonoda
S. Sonoda
KHK. Hamada
K. Hamada
The upgrade to JT-60SA tokamak was conducted within a Europe-Japan collaboration agreement including superconducting magnets implementation. In 2021, an arcing issue on a coil led to an overall magnet insulation reinforcement against high voltage. The Central Solenoid (CS), less accessible for repair, deserving specific attention versus voltage exposure, a risk mitigation was considered to address fast discharge event, which results in the highest voltage application. Maximum voltage during discharge being proportional to the external dump resistance (RDUMP), it is aimed at decreasing this resistance by 30%, inducing a slower current decrease after a quench, therefore a higher Joule energy absorbed by conductor. This induces a higher temperature rise in the conductor, increasing the risk of thermo-mechanical degradation due to hotspot occurrence. A risk analysis is performed to better understand the impact on the conductor. A methodology is followed to define streamlined hotspot risk criteria, backed by rationale and references to support the establishment of those methodological elements. Thermo-hydraulic simulations on the CS magnet, that were extensively produced, are analyzed to ensure that even after dump resistance modification, the hotspot safety limits are still respected. For this, a reference case and associated parametric studies were explored using THEA code. Finally, a positive recommendation is issued to validate and implement the JT-60SA project team decision to decrease the CS magnet RDUMP. Further perspectives are also evaluated.

29 January 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SSShogo Sonoda
Shogo Sonoda
HMHaruyuki Murakami
Haruyuki Murakami
KUKatsutomi Usui
Katsutomi Usui
SHShoichi Hatakeyama
Shoichi Hatakeyama
KHKazuya Hamada
Kazuya Hamada
LNLuca Novello
Luca Novello
The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.