Baojun Hui

Baojun Hui

Auto-generated profile, based on publicly available information

Baojun Hui

CSG Electric Power Research Institute Co., Ltd., Guangzhou 510663, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
WZWenbo Zhu
Wenbo Zhu
BHBaojun Hui
Baojun Hui
JLJianda Li
Jianda Li
THTao Han
Tao Han
LZLinjie Zhao
Linjie Zhao
SHShuai Hou
Shuai Hou
At present, the development of power cables shows three notable trends: higher voltage, longer distance and more complex environments. Against this backdrop, the limitations of traditional detection techniques in locating local defects have become increasingly apparent. Frequency Domain Reflectometry (FDR) has garnered sustained research attention both domestically and internationally due to its high sensitivity and accuracy in detecting localized defects. This paper aims to compare the defect localization effectiveness of the Fast Fourier Transform (FFT) method and the Inverse Fast Fourier Transform (IFFT) method within FDR. First, the differences between the two methods are analyzed from a theoretical perspective. Then, field tests are conducted on cables of varying voltage levels and lengths, with comparisons made using parameters such as full width at half maximum (FWHM) and signal-to-noise ratio (SNR). The results indicate that the FFT method is more suitable for low-interference or short cables, while the IFFT method is more suitable for high-noise, high-resolution, or long cables.

5 January 2026 in Fluids
Verified
Journal Article
Open access
PDF file
ZZZhao Zhang
Zhao Zhang
MFMingli Fu
Mingli Fu
CCChang Cai
Chang Cai
LZLinjie Zhao
Linjie Zhao
LJLei Jia
Lei Jia
MZMING ZHANG
MING ZHANG
Insulating oil leakage from oil-filled submarine cables compromised operational integrity and posed environmental risks. This study proposed a novel sealant-plugging repair technique that combines low-viscosity/high-permeability sealant permeation and high-viscosity/low-permeability sealant replacement and pressurization. The permeation process of the low-viscosity sealant, from the injection port to the outlet, was visualized using the Volume of Fluid (VOF) method. Analysis focused on: (1) sealant volume fraction in the sealing cavity; (2) sealant leakage volume fraction along the radial gaps at outlet 2; and (3) relative velocity of the permeating sealant along the radial gaps at outlet 2. Application of 0.4 MPa of sealant pressure achieved the key balance, characterized by: (i) Completed displacement of air from the sealing cavity; (ii) Full permeation of sealant into the gaps between the armored copper strip gaps and the radial gaps; (iii) Avoidance of the excessive sealant leakage flow observed at 0.5 MPa, promoting efficient sealant usage; (iv) A short time to reach permeation and leakage steady state. This study demonstrated the feasibility of the low-viscosity sealant penetration into both the gaps between the armored copper strips and the radial gaps under 0.4 MPa injection pressure. It provided theoretical and experimental guidance for this process within the sealant plugging repair technique.

12 September 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YZYunpeng Zhan
Yunpeng Zhan
QCQichao Chen
Qichao Chen
SHShuai Hou
Shuai Hou
JLJie Liu
Jie Liu
YCYun Chen
Yun Chen
LLLiyong Lai
Liyong Lai
Partial discharge (PD) generates transient acoustic-vibration signals that can be used for the passive monitoring of cable insulation. Unlike previous studies that separately addressed DFB-FL sensitivity, polymer-property effects, or acoustic attenuation in a particular cable, this study establishes an application-oriented cross-scale assessment that links material-level propagation loss with cable-scale detection by a distributed feedback fiber laser (DFB-FL)/fiber Bragg grating (FBG) system. This study compared the Young’s moduli of polypropylene (PP), cross-linked polyethylene (XLPE), and methyl silicone rubber (MQ), and measured their frequency-dependent attenuation coefficients along with those of insulating oil in the range of 50 to 300 kHz. Subsequently, a 250 mm-long, 220 kV XLPE cable specimen containing a needle-induced artificial cavity was tested at sensing distances of 0–7 cm and at four circumferential positions. For the three tested materials, the extrapolated initial response amplitude decreased as the Young’s modulus increased. The measured polymer attenuation coefficients were approximately 0.052–0.192 Np/cm, compared with approximately 0.018–0.033 Np/cm for insulating oil. Under the stated laboratory criteria, the lowest time-correlated apparent-charge event detected by the DFB-FL system was 16 pC. The DFB-FL peak-to-peak response decreased from 5.04 Vpp at 0 cm to 1.00 Vpp at 7 cm, crossing below the background threshold between 6 and 7 cm, which experimentally verifies the intrinsic connection among material attenuation, internal cable propagation paths, and sensor-placement constraints.