The healthy state of insulation in oil-impregnated bushings is traditionally evaluated by tanδ and capacitance at power frequency and mostly at 10 kV in the test standard. However, there has frequently been insulation accidents induced by moisture ingress (MI) for bushings that have passed the standard. The mechanism and new diagnostic features for MI into bushings were not distinct enough and an accurate test method is urgently needed research. To address this technical gap, a bushing model with a transparent sheath was designed and an ultrasonic humidifier device was adopted to simulate the environment of MI in bushings and recorded by digital camera. The parameters of dielectric dissipation factor, capacitance, partial discharge (PD), frequency domain response, and moisture content in oil were measured at room temperature with time. The results presented that both the increment dissipation factor at low frequency of 0.001 Hz and the increment dissipation factor of 1.2 Um could be used for detecting the earlier insulation defect of oil-impregnated paper (OIP) bushings. The phase resolved partial discharge (PRPD) can serve as the diagnostic basis of the severe state (S3) of insulation deterioration caused by MI into bushings around the phases of 0–117°, 151–303°, and 325–360°. The research findings would provide a useful reference for the condition diagnosis and maintenance of OIP bushings. Especially, the increment detection of Frequency Domain Spectroscopy (FDS) at the frequency of 1 mHz and 10 kHz was recommended firstly for the operative bushings in real sites.
In this paper, the calculation of the conductor temperature is related to the temperature sensor position in high-voltage power cables and four thermal circuits—based on the temperatures of insulation shield, the center of waterproof compound, the aluminum sheath, and the jacket surface are established to calculate the conductor temperature. To examine the effectiveness of conductor temperature calculations, simulation models based on flow characteristics of the air gap between the waterproof compound and the aluminum are built up, and thermocouples are placed at the four radial positions in a 110 kV cross-linked polyethylene (XLPE) insulated power cable to measure the temperatures of four positions. In measurements, six cases of current heating test under three laying environments, such as duct, water, and backfilled soil were carried out. Both errors of the conductor temperature calculation and the simulation based on the temperature of insulation shield were significantly smaller than others under all laying environments. It is the uncertainty of the thermal resistivity, together with the difference of the initial temperature of each radial position by the solar radiation, which led to the above results. The thermal capacitance of the air has little impact on errors. The thermal resistance of the air gap is the largest error source. Compromising the temperature-estimation accuracy and the insulation-damage risk, the waterproof compound is the recommended sensor position to improve the accuracy of conductor-temperature calculation. When the thermal resistances were calculated correctly, the aluminum sheath is also the recommended sensor position besides the waterproof compound.
To achieve exceptional recyclable DC cable insulation material using thermoplastic polypropylene (PP), we have introduced the organic polar molecule styrene-maleic anhydride copolymer (SMA) into PP-based insulation materials following the principles of deep trap modification. PP, PP/SMA, PP/ethylene-octene copolymer (POE), and PP/POE/SMA insulating samples were prepared, and their meso-morphology, crystalline morphology, and molecular structure were comprehensively characterized. The results indicate that SMA can be uniformly dispersed in PP with minimal impact on the crystalline morphology of PP. The DC electrical properties of the materials were tested at temperatures of 30, 50, and 70 °C. The findings demonstrate that the introduction of SMA can improve the DC properties of the material in both PP and PP/POE. The thermal stimulated depolarization current results reveal that SMA can introduce deep traps into the material, thereby improving its DC properties, which is in agreement with the quantum chemical calculation results. Subsequently, a bipolar carrier transport model was employed for coaxial cables to simulate the space charge distribution in the insulation layer of the four sets of insulation samples as well as the actual cable in service. The results highlight that SMA can significantly suppress space charge in PP and PP/POE systems, and it exhibits excellent electric field distortion resistance. In summary, the results illustrate that SMA is expected to be used as an organic deep trap modifier in PP-based cable insulation materials.
In the design and manufacturing of epoxy resin insulation components, complex structures can be achieved through multiple pours, thereby forming the structure of interface of laminated epoxy resin. This type of interface structure is often considered a weak link in performance which can easily accumulate charges and cause electric field distortion. However, research on the interlayer interface of epoxy resin has received little attention. In this study, epoxy samples with and without interlayer interfaces were prepared, and the space charge accumulation characteristics and trap characteristics of the samples were analyzed via pulsed electro-acoustic (PEA) and thermally stimulated depolarization current (TSDC) methods. The experimental results indicate that the Maxwell–Wagner interface polarization model cannot fully explain the charge accumulation at the interface. Due to the influence of the secondary curing, the functional groups in the post-curing epoxy resin can move and react with the partially reacted functional groups in the prefabricated epoxy resin layer, resulting in a weak cross-linking network at the interface. With the increase in temperature, the molecular chain segments in the weak cross-linked region of the interface become more active and introduce deep traps at the interface, thereby exacerbating the accumulation of interface charges. In addition, due to the influence of interface polarization and weak cross-linking, the ability of the interface charges to cause field strength distortions decreases with the increase in applied field strength. This research study can provide a theoretical reference for the interfacial space charge transport characteristics of epoxy-cured cross-linked layers and provide ideas for regulating interfacial cross-linking to suppress interfacial charge accumulation.
Accurate detection of the internal decomposition components of SF6 electrical equipment plays an important role in the evaluation of equipment status. However, gas samples are usually taken out for detection at present, which makes it difficult to understand the real situation inside the equipment. In this paper, a carbon nanotube-coated fiber gas sensor is proposed, which has the potential to be applied as a built-in gas sensor. The fiber loop ring-down (FLRD) gas detection system based on the carbon nanotube-coated fiber gas sensor was built, and the detectable decomposition components among the four typical SF6 decomposition components of SO2, SO2F2 and SOF2 and CO were analyzed. The results showed that the fiber gas sensor was most sensitive to CO. Based on density functional theory, it was found that single-walled carbon nanotubes had the best adsorption effect on CO molecules under the same conditions, with the adsorption energy reaching −0.150 Ha. The detection performance of the system for CO was studied, and the results showed that there was a good linear relationship between CO concentration and ring-down time: R2 was 0.984, the maximum inversion error of 0~200 ppm CO was 1.916 ppm, and the relative error was 4.10%. The sensitivity of the system was 0.183 ns/ppm, and the detection limit of the system was 19.951 ppm. The system had good stability, with the standard deviation of single-point repeatability being 0.00356, and the standard deviation of the long period of the experiment being 0.00606. The research results provide a new idea for the detection of SF6 decomposition components, and lay the foundation for the component detection method of built-in fiber sensor of SF6 electrical equipment.
C6F12O has been introduced as the potential alternative gas to SF6 because of its excellent insulation properties and great eco-friendly performance. Considering that C6F12O may react with the internal materials of switchgears in practical applications, its compatibility with metal materials must be tested to evaluate its long-term application possibilities. In this work, the compatibility of C6F12O–N2 gas mixtures with aluminum and copper was tested at different temperatures by setting up a heat-aging reaction platform between the gas and each metal. The metal surface morphology and gas composition before and after the reaction were compared and analyzed. The results show that the surface color of the copper sheet changed considerably, and the corrosion degree of the surface deepened with the increase of temperature. The decomposition of C6F12O was also promoted. In contrast, aluminum did not react severely with the gas mixture. The compatibility of the gas mixture with aluminum was generally better than that of copper.