David Pommerenke

David Pommerenke

Auto-generated profile, based on publicly available information

David Pommerenke

Graz University of Technology

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2007 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
SSShishuang Sun
Shishuang Sun
GLGeping Liu
Geping Liu
JDJames L. Drewniak
James L. Drewniak
DPDavid J. Pommerenke
David J. Pommerenke
A statistical cable bundle model is developed to account for the random disturbance of the wire positions along hand-assembled cable bundles. The nonuniform random bundles are modeled as n-cascaded segments of a uniform multiconductor transmission line. At each section, all wire positions are disturbed with random numbers obeying a Gaussian distribution. In addition, a spline interpolation function is used to improve the continuity of wires winding along the bundle. The wire crosstalk and the common-mode (CM) current distribution along the bundle can be calculated with simulation program with integrated circuit emphasis (SPICE)-like solvers. By injecting the CM current along the bundle into a full-wave tool, e.g., finite-difference time domain (FDTD), as impressed current sources, the system-level electromagnetic emissions from the cable bundles can be predicted. The model has been experimentally validated with a controlled laboratory setup.

23 May 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SYSen Yang
Sen Yang
QHQiaolei Huang
Qiaolei Huang
GLGuanghua Li
Guanghua Li
RZReza Zoughi
Reza Zoughi
DPDavid J. Pommerenke
David J. Pommerenke
In near-field scanning using H-field probes, E-field coupling is a major concern. E-field suppression performance must be characterized before an H-field probe can be used for near-field scanning. Common method of measurement involves measuring the E-field coupling in the same location where the strongest H-field coupling occurs. In microstrip line traces, it is assumed that this occurs right above the center of the trace and less coupling at all other locations across the microstrip line. In this paper, we show that the maximum E-field coupling occurs at a location slightly offset from the trace center. The E-field coupling to a shielded H-field probe at such a position leads to differential-mode coupling, which the standard shield of an H-field probe is unable to suppress. The coupling mechanism is investigated and a differential E-field coupling suppression approach is proposed. For the H-field probe used in this paper, a proposed floating plate is shown to improve the measured E-field suppression ratio by a factor of 18 dB compared to a similar probe without this modification.

1 August 2018 in IEEE Systems Journal
Verified
Journal Article
Closed access
NANiaz Ahmed
Niaz Ahmed
ARAndriy Radchenko
Andriy Radchenko
DPDavid Pommerenke
David Pommerenke
YZYahong Rosa Zheng
Yahong Rosa Zheng
A set of low-cost and energy-efficient sensor nodes are designed and implemented using magnetic induction (MI) communications for wireless sensor networks (WSN), which are especially suited for underwater and underground networks where the conventional mode of communication does not perform well. Hardware features of the sensor nodes include a three-dimensional MI coil antenna and its different configurations for transmit and receive operations, low-power circuits for sleep mode, several types of sensors, data storage, and best transmit/receive circuits selected to achieve the maximum communication range with low-power consumption. The material cost of a sensor node is less than $\$$ 100 USD at the prototyping stage and can be drastically reduced at volume production. Software design utilizes low-power modes of microcontrollers and power supply circuits, state machine implementation of sleep, receive, sensing, and transmit modes, range estimation from received signal strength indicators (RSSIs), and medium access protocols, such as carrier sense multiple access (CSMA). Extensive lab and field tests conducted with the sensor nodes demonstrate promising performance in terms of low-power consumption, communication range, range estimation, and robustness against mismatching of coil orientations, and networking capabilities. The current consumption is as low as 60 $\mu$ A in sleep mode, 0.49 $\text{m}$ A in receive mode, and 253 $\text{m}$ A in transmit mode. The sensor node achieves a maximum of 40-m range with 1 kb/s data rate at 125 kHz carrier frequency.

22 December 2017 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
SSSatyajeet Shinde
Satyajeet Shinde
KMKohei Masuda
Kohei Masuda
GSGuangyao Shen
Guangyao Shen
APAbhishek Patnaik
Abhishek Patnaik
TMTamar Makharashvili
Tamar Makharashvili
VKVictor Khilkevich
Victor Khilkevich
An equivalent two terminal model based on the Thevenin equivalents describes the common mode (CM) currents on the input and output side of two widely used types of dc-to-dc power converters—buck and boost. Thus, it describes a nonlinear circuit by a linear equivalent circuit. The maximized spectrum of the CM currents is extracted for converters with stochastic signals using a novel characterization procedure. The extracted Thevenin model is used in co-simulation combined with a full-wave electromagnetic solver to predict the radiated emissions from the system consisting of the shielded dc–dc converters with attached cables and a DC brushless motor as load. The results using the terminal model agree well with the measurements providing that the actual CM loads are within the range of CM loads used while obtaining the Thevenin equivalent circuit.

21 March 2018 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
XCXiong Chen
Xiong Chen
YHYongning He
Yongning He
SYSen Yang
Sen Yang
CWcui wanzhao
cui wanzhao
YZYao-Jiang Zhang
Yao-Jiang Zhang
JFJun Fan
Jun Fan
This paper presents a novel passive intermodulation (PIM) prediction method considering random contact behavior using a Monte Carlo method for a coaxial connector. A smart contact model for a contact unit at a microcosmic level is proposed. Using Monte Carlo approximation and micromeasurements, different random distributed contact samples for different contact components inside the coaxial connector are reconstructed. In the experiment, PIM on inner and outer conductor was tested and compared with predication. A good agreement proves the proposed PIM prediction method is efficient. Rather than generating a single PIM prediction value, this method will give a PIM confidence interval for all the potential PIM values considering the contact force statistical behavior. The work will help analyze fluctuated PIM on coaxial connectors and inspire a new method to predict PIM risk.

6 April 2017 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Open access
GSGuangyao Shen
Guangyao Shen
SYSen Yang
Sen Yang
JSJingdong Sun
Jingdong Sun
SXShuai Xu
Shuai Xu
DPDavid J. Pommerenke
David J. Pommerenke
VKVictor Khilkevich
Victor Khilkevich
Creating an equivalent field source is an efficient method for predicting radiated emissions from IC structures. In this paper, the maximum radiated emissions for a heat-sink/IC structure is predicted by creating an equivalent source from the measured electrical field (E-field) in the gap between the heatsink and IC. The E-field is detected by an E-field probe made of an open coaxial cable coated with absorbing material. A numerical model is built in the computer simulation technology microwave studio to obtain the maximum radiated field, where the measured E-field is used as a source to excite the heat-sink model. The evaluated maximum radiated field is in good agreement with the measured value; the error is within 7 dB up to 40 GHz for the source with phase, and 7 dB up to 10 GHz for the phaseless measurement.