Jinke Li

Jinke Li

Auto-generated profile, based on publicly available information

Jinke Li

China Energy Engineering Group, Jiangsu Power Design Institute Co., Ltd., Nanjing 211102, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
JLJinke Li
Jinke Li
Georgios KonstantinouGeorgios Konstantinou
Georgios Konstantinou
HWHarith R. Wickramasinghe
Harith R. Wickramasinghe
Josep PouJosep Pou
Josep Pou
High-voltage direct current (HVDC) transmission systems based on modular multilevel converters (MMCs) are a promising solution for efficient bulk power transmission over long distances. As grid-connected converters, the occurrence of grid-side faults is rather common, leading to imbalances and distortions of the ac-side voltages. Therefore, operation and control of MMC-HVDC systems under grid imbalances becomes of great significance in order to satisfy grid codes and reliability requirements of the system. The aim of this paper is to provide a comprehensive review of operation and control methods applied to MMC-HVDC systems with a specific focus to unbalanced ac grid conditions. The methods are classified based on their main control targets that include ac-side power control, control of the circulating current, and dc-side power ripple suppression control. Special attention is given to the comparison of the different control methods and specific requirements under certain operating conditions that include grid, load or internal imbalances.

30 August 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JLJinke Li
Jinke Li
Georgios KonstantinouGeorgios Konstantinou
Georgios Konstantinou
HWHarith R. Wickramasinghe
Harith R. Wickramasinghe
Josep PouJosep Pou
Josep Pou
Xuezhi WuXuezhi Wu
Xuezhi Wu
XJXinmin Jin
Xinmin Jin
The negative-sequence current of a modular multilevel converter (MMC) under unbalanced ac grid conditions increases the voltage ripples of the submodule capacitors. This paper investigates the impact of circulating current control in capacitor voltage ripples under different unbalanced ac grid conditions, while considering multiple control objectives and independent control of active and reactive power. It is demonstrated that higher order harmonic injection in the circulating current through a reference calculation based on instantaneous information improves operation of the MMC reducing capacitor voltage ripples at the cost of increased peak arm current and dc current oscillations. The efficacy of the circulating current control is validated through real-time digital simulations of an 800 MVA benchmark MMC high-voltage direct current transmission system.

29 May 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JLJinke Li
Jinke Li
Georgios KonstantinouGeorgios Konstantinou
Georgios Konstantinou
HWHarith R. Wickramasinghe
Harith R. Wickramasinghe
Christoper D. TownsendChristoper D. Townsend
Christoper D. Townsend
Josep PouJosep Pou
Josep Pou
Negative- and zero-sequence internal currents of a modular multilevel converter (MMC) under unbalanced ac-grid conditions can increase the peak voltage of the submodule (SM) capacitors, which should be kept below a maximum voltage limit. This paper investigates the impact of offset pulse-width modulation (OPWM) and zero sequence voltage injection on reducing peak SM capacitor voltages of the MMC during unbalanced ac-grid conditions. It is demonstrated that OPWM extends the operating range of the MMC for a given set of restrictions, as it leads to a reduction of capacitor voltage in every phase by utilizing all the SMs in the arms. Zero sequence voltage injection further reduces the maximum SM capacitor voltage among three phases under certain conditions. Simulation results from an 800-MVA MMC-based high-voltage direct current (HVDC) transmission system demonstrate the effect of OPWM in the operation of the converters and the efficacy of the method compared to standard modulation methods.

13 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
HJHaipeng Jia
Haipeng Jia
YIN JINGYUANYIN JINGYUAN
YIN JINGYUAN
TWTongzhen Wei
Tongzhen Wei
QHQunhai Huo
Qunhai Huo
JLJinke Li
Jinke Li
LWLixin Wu
Lixin Wu
The analysis and calculation of the short-circuit fault current in the DC grid is of great significance to the design and configuration of the converter station and DC circuit breaker parameters. The existing flexible DC system not only includes the modular multilevel converter (MMC) converter, but also needs power equipment such as the fault current limiter and DC circuit breaker. Therefore, the system modeling and short circuit calculation of the multi-terminal DC system after adding the DC circuit breaker are also of great significance for the design of DC power system parameters and the grid troubleshooting ability. In this paper, firstly, the parameters of the four-terminal DC system of the modular multilevel converter (MMC) are simplified, and the analytical solution of the short circuit fault current of the multi-terminal DC system is given. Then, the external characteristics of the cascaded hybrid DC circuit breaker are modeled. Based on the equivalent circuit of the fault current in different stages, the short circuit calculation method of four-terminal MMC system with DC circuit breaker is obtained. This method can effectively describe the overall trend of fault current and provide the basis for the configuration of DC line protection settings and DC circuit breaker related parameters.

7 July 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
WWWen Wu
Wen Wu
Xuezhi WuXuezhi Wu
Xuezhi Wu
LWLuocheng Wang
Luocheng Wang
TZTiefu Zhao
Tiefu Zhao
LJLong Jing
Long Jing
JLJinke Li
Jinke Li
Multi-port DC power flow controller (M-DCPFC) has become one of the most attractive solutions to regulate the power flow in the modular multi-level converter based multi-terminal DC (MMC-MTDC) transmission system. However, the current studies on the M-DCPFC are mainly focus on the power flow control under the normal operation in the transmission system. To eliminate the impact of the power oscillation which frequently happens because of the unbalanced AC grid, this paper proposes an integration to calibrate the active damping control into the M-DCPFC. It introduces the complementary virtual damping to the transmission lines in order to reduce the DC current fluctuations, which suppresses the DC side power oscillations. In this paper, the influence of the unbalanced AC grid on the MMC-MTDC transmission system is investigated and the active damping control of M-DCPFC is presented in detail. A four-terminal MMC-MTDC transmission system is developed as the test platform in the real-time model-in-the-loop (MIL) simulation. The proposed active damping control is validated and shows its effectiveness under different unbalance conditions.

1 October 2017
Verified
Conference Paper
Closed access
JLJinke Li
Jinke Li
HWHarith R. Wickramasinghe
Harith R. Wickramasinghe
Georgios KonstantinouGeorgios Konstantinou
Georgios Konstantinou
Josep PouJosep Pou
Josep Pou
XJXinmin Jin
Xinmin Jin
Energy balancing of the alternate arm converter (AAC) takes place during the overlap period, when a circulating current flows through both arms of the converter. In this paper, the limitations of the commonly used energy balancing methods of the AAC under grid imbalances are demonstrated. It is shown that the overlap control can only provide sufficient energy balancing for a relatively limited voltage imbalance degree of the ac voltages and larger imbalances greatly impact the energy balancing of the AAC. The limitations of the overlap control are demonstrated through real-time digital simulations of an 800-MVA benchmark AAC model under single-phase, phase-to-phase and three-phase ac imbalances with varying imbalance degrees.