9 April 2019 in IEEE Transactions on Industrial Electronics
Differential power processing (DPP) is a promising architecture to solve the issue caused by mismatches among PV submodules. To eliminate the mismatch power losses, this paper presents an optimized PV-to-bus DPP system with submodule-level individual maximum-power-point tracking (MPPT) and module-level minimum-power tracking (MPT) simultaneous implementation according to the built mathematical model of the power processed by DPP converters with respect to the string current. Furthermore, a flexible time-sharing algorithm is adopted to reduce the number of MPPT units. Compared with other solutions such as PV optimizer, the proposed scheme can reduce the effects of mismatches to the minimum regardless of mismatch conditions. The system cost is reduced since only one adaptive MPPT controller is required. Besides, the system efficiency is improved due to the true MPPT implementation and MPT control. Both simulation and experimental tests are provided to validate the effectiveness of the proposed scheme.
20 August 2021 in IEEE Transactions on Power Electronics
The dc power transmission system has been obviously attracting more research interests in recent years. In order to satisfy the high-reliability requirement of the dc power transmission system, the power converter should be able to keep uninterrupted operation after multiple unexpected faults. However, high fault-tolerant capability usually leads to the bulky redundant circuit, which increases the cost, volume, and complexity of the power converter. Thus, a fault-tolerant dual active bridge (DAB) converter is proposed to maintain the power transferring ability under multiple unexpected open-circuit faults (OCFs) conditions, which can significantly enhance the reliability of the dc power transmission system. By reconfiguring the central-tapped transformer and two symmetrical auxiliary inductors, the half-bridge conduction branch is built to maintain uninterrupted operation when a single or dual OCF has occurred. The proposed fault-tolerant strategy only requires four extra voltage sensors to detect and locate OCFs for the reconfiguration process. Thus, it significantly improves the system reliability with a low additional cost. Besides, the inductor current, transmission power, and the small-signal models of the proposed fault-tolerant converter have been presented. It proves the proposed fault-tolerant topology can smoothly switch between normal and postfault operation due to the constituency of the inductor current. Finally, the 250-W prototype is designed to verify the advantage of the proposed fault-tolerant DAB converter.
6 October 2020 in IEEE Transactions on Industry Applications
2 March 2020 in IEEE Transactions on Power Electronics
Differential power processing (DPP) is regarded as a promising architecture in solving mismatching issues among photovoltaic (PV) submodules. Although conventional totalminimum- power-point (TMPP) based real-time optimization algorithm by using the distributed submodule-level maximum power point tracking (MPPT) and simultaneously the centralized total-minimum-power tracking (TMPT) shows effectiveness in maximizing the power yield. However, uneven power stress among DPP converters, large oscillations, high additional cost for communication among DPP converters, and complicated implementation hinder the practical application. This paper proposed a low-complexity power-balancing-point (PBP) based optimization algorithm to reduce the system cost and size, improve the system efficiency, and realize the standardized modular design for DPP converters. Furthermore, simple submodule-level voltage equalization (VE) control is implemented to eliminate expensive communication and relieve the control complexity while guarantee high MPP efficiency. The proposed algorithm can reduce the power rating of DPP converters compared with conventional TMPP-based control, which is beneficial to the improvement of system cost, reliability and lifetime. Both simulation and experimental results under various scenarios are provided to validate the advantages of the proposed algorithm.
1 July 2021 in IEEE Transactions on Power Electronics
With the increase of the component number, the power stress distribution among differential power processing (DPP) converters, control implementation, system cost, and reliability become the most challenging issues for a practical photovoltaic (PV) DPP system. This article introduces an improved power-rating balance (IPRB) control for the PV-to-bus based DPP architecture that ensures each PV submodule operate at its true maximum power point (MPP) while achieving more balanced power stress distribution and higher reliability. Specifically, a submodule-level finite-state-machine-based MPP tracking is implemented to guarantee always maximum power yield, whereas a string-level power-rating balancing (PRB) control is adopted to balance the unit-maximum proceeded power by DPP converters based on the built power flow model with respect to the string current. A comprehensive comparison of advanced control strategies for PV-to-bus DPP architectures, including least power point tracking, voltage equalization (VE) based PRB control, and the proposed IPRB, has been carried out with the mission-profile-based reliability assessment under different partial shading scenarios. Component-failure-rate-based reliability analysis shows that the PV-to-bus DPP architecture with the proposed IPRB control can significantly improve the system reliability. Main simulation and experimental evaluations are carried out to verify the effectiveness of the proposed control.
17 August 2023 in IEEE Transactions on Sustainable Energy
Recent power curtailment-based photovoltaic (PV) flexible power point tracking (FPPT) algorithms mainly adopted intricate curve fitting or sophisticated curve-scanning mechanisms to ensure the grid supportive functionalities under partial shading conditions (PSCs), showing the limitations of mathematical solidity or system dynamics improvement. Accordingly, a novel fast-speed partial-shading-tolerant FPPT (PST-FPPT) algorithm is proposed in this article. Regarding the proposed scheme, a modified explicit PV model is developed to express the key operation points with the assistance of several representative current-voltage samples from the initialization process, which is beneficial to computational burden reduction and irradiance sensors removal. Additionally, to guarantee the tracking speed to system dynamics, a set point estimation-based direct voltage regulation strategy is proposed in this article, eliminating the redundant searching in approaching the predefined power command. Simulation and experimental evaluations under various PSCs and operational circumstances validated the effectiveness of the proposed control.