Oliver Kliebisch

Oliver Kliebisch

Auto-generated profile, based on publicly available information

Oliver Kliebisch

Institute of Technical Physics, German Aerospace Center, Pfaffenwaldring 38-40, 70569 Stuttgart, Germany

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2022 in Optics Express
Verified
Journal Article
Open access
OKOliver Kliebisch
Oliver Kliebisch
HUHugo Uittenbosch
Hugo Uittenbosch
JTJohann Thurn
Johann Thurn
PMPeter Mahnke
Peter Mahnke
Multi-classification using a convolutional neural network (CNN) is proposed as a denoising method for coherent Doppler wind lidar (CDWL) data. The method is intended to enhance the usable range of a CDWL beyond the atmospheric boundary layer (ABL). The method is implemented and tested in an all-fiber pulsed CWDL system operating at 1550 nm wavelength with 20 kHz repetition rate, 300 ns pulse length and 180 µJ of laser energy. Real-time pre-processing using a field programmable gate array (FPGA) is implemented producing averaged lidar spectrograms. Real-world measurement data is labeled using conventional frequency estimators and mixed with simulated spectrograms for training of the CNN. First results of this methods show that the CNN can outperform conventional frequency estimations substantially in terms of maximum range and delivers reasonable output in very low signal-to-noise (SNR) situations while still delivering accurate results in the high-SNR regime. Comparing the CNN output with radiosonde data shows the feasibility of the proposed method.

7 November 2018 in Optica
Verified
Journal Article
Open access
PDF file
OKOliver Kliebisch
Oliver Kliebisch
DHDirk Heinecke
Dirk Heinecke
SBStefano Barbieri
Stefano Barbieri
GSGiorgio Santarelli
Giorgio Santarelli
HLHua Li
Hua Li
TDThomas Dekorsy
Thomas Dekorsy
Terahertz frequency metrology by radio frequency downconversion using femtosecond optical sampling relies on the harmonic factor retrieval between the terahertz frequency and the optical sampling rate. At typical femtosecond laser repetition rates, this imposes an ambiguity for frequency metrology. We report on a dual-comb sampling system for the unambiguous frequency measurement of terahertz quantum cascade lasers with hertz-level precision. Two Ti:sapphire oscillators with 10 GHz repetition rate are used for the electro-optic sampling of terahertz radiation at 2.5 THz emitted by actively mode-locked terahertz quantum cascade lasers with 9.7 GHz and 19.6 GHz repetition rates. By coherent downconversion, the emitted terahertz waveforms are measured in the radio frequency domain. The terahertz frequency comb is stabilized by employing a phase-locked loop on a radio frequency beat-note signal. A second infrared sampling comb is used to measure the absolute frequencies of the terahertz radiation. This method, which is based on the detuning of the sampling repetition rates, allows the direct retrieval of the quantum cascade laser’s absolute frequency in real time without using additional optical frequency references for calibration. In order to demonstrate the feasibility of the stabilization and readout technique, a high-resolution spectroscopy measurement on gaseous methanol is presented.

1 September 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
OKO. Kliebisch
O. Kliebisch
PMP. Mahnke
P. Mahnke
Laser Doppler anemometry (LDA), sometimes also referred to as cw Doppler lidar, is a promising optical technique for the measurement of primary flight data such as true air speed, angle of attack, and angle of sideslip. Multiple flight campaigns have shown the potential of this technique for future air data systems. However, LDA remains challenging in low aerosol environments at cruise altitude, and the high raw-data bandwidth of LDA sensors impedes real-time operation. In this work, we present a real-time preprocessing scheme, which is optimized to handle the signal structure of single-particle scattering events. We discuss how this scheme is implemented on system-on-chip field-programmable-gate-array hardware and how it is used with a four channel laser Doppler anemometer.

8 February 2023 in Optics Express
Verified
Journal Article
Closed access
HUHugo Uittenbosch
Hugo Uittenbosch
OKOliver Kliebisch
Oliver Kliebisch
RLRaoul-Amadeus Lorbeer
Raoul-Amadeus Lorbeer
PMPeter Mahnke
Peter Mahnke
We present a modified version of the two-arm, two-color, single second harmonic generation heterodyne dispersion interferometer, as introduced by Irby et. al. [Rev. Sci. Instrum. 70, 699 (1999) ]. The amount of optical elements is reduced and digital in-phase and quadrature demodulation is used to retrieve the phase shift from a single photodetector signal. The intrinsic system noise and drift for this device are analyzed by measuring the Allan deviation. We investigate the use of this device for relative atmospheric pressure measurement. Relative pressure measurements are performed in a pressure chamber and referenced against a piezoresistive pressure transceiver to demonstrate the concept. It was found that the deviation was less than 150 Pa and an error estimation has been derived.Published by Optica Publishing Group under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.

25 August 2023 in Applied Optics
Verified
Journal Article
Open access
OKOliver Kliebisch
Oliver Kliebisch
MDMatthias Damm
Matthias Damm
PMPeter Mahnke
Peter Mahnke
Using an airborne vector laser Doppler anemometer (LDA) to measure the air flow outside of the boundary layer of an airplane is a promising optical technique. Measurement of the primary flight data like true airspeed, the angle of attack, and the angle of sideslip can be directly derived from the measured wind vector. We developed an experimental system with interchangeable telescopes to study the change in the LDA sensitivity and signal rate, depending on the focusing of the measurement beam. The system has a real-time-capable field programmable gate array data acquisition system, which also can record full data dumps for off-line analysis. This paper presents the first results of an airborne measurement campaign. The true airspeed is measured with an residual error of 1% compared to the five-hole flow sensor. The angle of sideslip and the angle of attack show a standard deviation of the residual error of 0.6∘ for the angle of sideslip and 0.2∘ for the angle of attack.

6 May 2024 in IEEE Open Journal of Instrumentation and Measurement
Verified
Journal Article
Open access
RLRaoul-Amadeus Lorbeer
Raoul-Amadeus Lorbeer
MBMatthias Bittner
Matthias Bittner
OKOliver Kliebisch
Oliver Kliebisch
PMPeter Mahnke
Peter Mahnke
Tunable diode-laser absorption spectroscopy (TDLAS) sensors have shown to be applicable to e.g. temperature and pressure measurements in gases. These parameters are indispensable in modern avionics. Even though these systems performed well in laboratory or closed environments, the harsh conditions of avionic flight introduce sources of error. To cope with these challenges, altered variants of the classical direct TDLAS may be taken into consideration. Here, we investigate the differences between an all fiber direct TDLAS and a Mach-Zehnder based amplitude modulated TDLAS variant. We are able to demonstrate the increased noise immunity of the amplitude modulated system as well as the use of the oxygen A-band for the use as an optical pressure detector.