Elmira Damirovna Abdrakhmanova

Elmira Damirovna Abdrakhmanova

Auto-generated profile, based on publicly available information

Elmira Damirovna Abdrakhmanova

Ufa University of Science and Technology

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2024 in Russian Physics Journal
Verified
Journal Article
Closed access
PDF file
VSV. D. Sitdikov
V. D. Sitdikov
EKElvira Khafizova
Elvira Khafizova
MPM. V. Polenok
M. V. Polenok
EAE. D. Abdrakhmanova
E. D. Abdrakhmanova

1 January 2024 in Materials. Technologies. Design
Verified
Journal Article
Open access
PDF file
UTUfa University of Science and Technology
Ufa University of Science and Technology
EAElmira Damirovna Abdrakhmanova
Elmira Damirovna Abdrakhmanova
EKElvira Dinifovna Khafizova
Elvira Dinifovna Khafizova
MPMilena Vladislavovna Polenok
Milena Vladislavovna Polenok
RIRinat Kadykhanovich Islamgaliev
Rinat Kadykhanovich Islamgaliev
ХЙХакан Йылмазер
Хакан Йылмазер
Bioresorbable zinc alloys are ever more often regarded as promising materials for medical implants and vascular stents since they have a lower corrosion rate in a physiological environment in comparison with magnesium alloys. At the same time, products made of zinc alloys must have a controlled corrosion rate to provide the required time for the recovery of the body. It is known that in determining the corrosion rate, an important role is played by the choice of the test method and its parameters (corrosive environment, environment temperature, the sample's exposure time in the corrosive environment). In the present study, the gravimetric method was used, based on a precise measurement of the substance mass prior to and after testing. The surface of the samples subjected to corrosion tests was investigated using scanning electron microscopy and energy-dispersive analysis. The aim of the present study is to reveal the effect of the samples' exposure time in a corrosive environment, as well as the frequency of surface cleaning, on the corrosion resistance of the Zn-1Fe-1Mg biodegradable zinc alloy. It is shown that under the same test conditions but different frequencies of surface cleaning, the corrosion rates may differ by a factor of 3.8. Биорезорбируемые цинковые сплавы все чаще рассматриваются как перспективные материалы для медицинских имплантатов и сосудистых стентов, поскольку они обладают меньшей скоростью коррозии в физиологической среде по сравнению с магниевыми сплавами. Вместе с тем изделия, сделанные из цинковых сплавов, должны обладать контролируемой скоростью коррозии для обеспечения нужного временного интервала для восстановления организма. Известно, что при определении скорости коррозии важную роль играет выбор метода испытаний и его параметров (коррозионная среда, температура окружающей среды, время выдержки образца в коррозионной среде). В настоящей работе был использован гравиметрический метод, основанный на точном измерении массы вещества до и после испытаний. Поверхность образцов, подвергнутых коррозионным испытаниям, исследовали с применением методов сканирующей электронной микроскопии и энергодисперсионного анализа. Целью настоящей работы является определение влияния времени выдержки образцов в коррозионной среде, а также периодичности очистки поверхности на коррозионную стойкость биодеградируемого цинкового сплава Zn-1Fe-1Mg. Показано, что при одинаковых условиях испытаний, но при разной периодичности очистки поверхности скорость коррозии может отличаться в 3,8 раза.

1 January 2024 in Frontier materials & technologies
Verified
Journal Article
Open access
PDF file
EAElmira D. Abdrakhmanova
Elmira D. Abdrakhmanova
EKElvira Khafizova
Elvira Khafizova
MPMilena V. Polenok
Milena V. Polenok
RNRuslan Kamilovich Nafikov
Ruslan Kamilovich Nafikov
Elena KorznikovaElena Korznikova
Elena Korznikova
Currently, scientists search for new materials for temporary implants that can dissolve in the body, which leads to the fact that there is no need for repeated surgery. In the last decade, scientific interest has focused on zinc-based materials because, unlike other metals, it has suitable corrosion rates and good biocompatibility. The paper describes an experiment for the study of the influence of deformation on the microstructure, strength and corrosion properties of an alloy of the Zn–Fe–Mg system. The authors carried out energy dispersive analysis and calculation of the volume fraction of the second phase of the Zn–Fe–Mg zinc alloy. The corrosion properties of the Zn–Fe–Mg zinc alloy with different microstructures (before and after high-pressure torsion) were studied using the gravimetric method under conditions simulating conditions inside a living organism (temperature, corrosive environment composition). During the tests, the corrosion mechanism was determined, its rate and mass loss of the samples were calculated. The relief of the corrosion surface was studied using scanning electron microscopy. It has been found that the destruction of the material in a corrosive environment occurs through a matrix containing the active Mg metal. The results of calculations of the corrosion rate for the original sample and samples subjected to high-pressure torsion differed due to a more even distribution of second phase particles during severe plastic deformation. In this work, by alloying zinc with iron and magnesium, as well as using high-pressure torsion, it was possible to increase the microhardness of the samples to 239.6±8 HV, which is a high indicator for zinc alloys.

1 August 2025 in Russian Journal of Non-Ferrous Metals
Verified
Journal Article
Closed access
PDF file
MPM. V. Polenok
M. V. Polenok
EKElvira Khafizova
Elvira Khafizova
RIR. K. Islamgaliev
R. K. Islamgaliev
RNRuslan Kamilovich Nafikov
Ruslan Kamilovich Nafikov
EAE. D. Abdrakhmanova
E. D. Abdrakhmanova
WWWei Wei
Wei Wei
This study investigated the microstructure and mechanical properties of a Zn–4Ag–1Cu (wt %) alloy processed by high-pressure torsion (HPT) at room temperature through 1 to 10 turns. Microstructural analysis reveals that HPT processing results in the formation of a homogeneous ultrafine-grained (UFG) structure in the alloy samples, with a grain size ranging from 250 to 600 nm, containing nanoscale particles of secondary phases. In the early stages of deformation, after HPT with 1 to 10 turns, a significant increase in strength properties is observed in the UFG samples compared to the initial state. The yield stress and ultimate tensile strength reach 165 and 236 MPa, respectively. An increase in the number of HPT turns from 1 to 10 is accompanied by a decrease in strength and a notable increase in the plasticity of the samples. The elongation to failure increases by an order of magnitude, from 13 to 112 and 250%. Experimental data confirm the manifestation of grain boundary sliding and dynamic recrystallization effects, leading to a significant increase in the plasticity of the UFG alloy at room temperature. This study demonstrates the high efficiency of using the HPT method to form a UFG structure in the Zn–4% Ag–1% Cu alloy, which provides a combination of properties attractive for bioresorbable implants and stents used in medicine.

7 January 2025 in Russian Physics Journal
Verified
Journal Article
Closed access
PDF file
EAE. D. Abdrakhmanova
E. D. Abdrakhmanova
FNF. V. Nugamanov
F. V. Nugamanov
EKElvira Khafizova
Elvira Khafizova
RIRinat Islamgaliev
Rinat Islamgaliev
MPM. V. Polenok
M. V. Polenok
HYH. Yilmazer
H. Yilmazer

31 March 2026 in Frontier materials & technologies
Verified
Journal Article
Open access
PDF file
EAE.D. Abdrakhmanova
E.D. Abdrakhmanova
EKElvira Khafizova
Elvira Khafizova
MPM.V. Polenok
M.V. Polenok
RIR.K. Islamgaliev
R.K. Islamgaliev
ZLZhen Li
Zhen Li
ЙХЙылмазер Хакан
Йылмазер Хакан
Problem. Currently used materials for ureteral stents are unable to eliminate inflammation, exhibit low strength, and require a second surgery for removal. Metallic bioresorbable stents can reduce the burden on the patient’s body and eliminate additional operations for product removal. Aim. To roduce a new biocompatible Zn-1 %Cu-1 %Mn alloy and, using equal-channel angular pressing at elevated temperature, to develop an improved set of mechanical properties for potential application as a material for ureteral stents. Methods. The Zn-1 %Cu1 %Mn alloy was subjected to equal-channel angular pressing at 200 °C (8 passes, route Bc). The microstructure and elemental composition were studied using transmission electron microscopy with energy-dispersive analysis. Mechanical properties were evaluated under uniaxial tension (strain rate of 10–3 с –1 , at least 3 samples per each condition), Vickers microindentation with construction of hardness distribution maps, and fractographic analysis of fracture surfaces using a scanning electron microscope. Results. By indexing diffraction patterns, it was established that the deformation processing promotes the precipitation of MnZn13 phase particles, which may have a strengthening effect. Fractographic analysis of fractured samples after tension showed a change in the fracture character from brittle to ductile with deep dimples. Carrying out equal-channel angular pressing (ECAP) for 8 passes at elevated temFrontier Materials & Technologies. 2026. № 1 17 Абдрахманова Э.Д., Хафизова Э.Д., Поленок М.В. и др. «Влияние высокотемпературного РКУП на структуру и механические…» peratures allowed increasing the ultimate tensile strength by 2.3 times, the offset yield strength by 3 times, and the percentage elongation by 8 times. The distribution of microhardness values becomes more uniform with a n increase in passes from 2 to 8, and the gap between the smallest and largest values decreases. Conclusions. It was established that the deformation method (ECAP, 8 passes) for the new biocompatible Zn-1 %Cu-1 %Mn alloy develops an improved set of mechanical properties, which opens up possibilities for its application in medical purposes.