Australian Centre for Research on Separation Science (ACROSS), Sandy Bay, 7006, Australia; ARC Training Centre for Hyphenated Analytical Separation Technologies (HyTECH), Chemistry, School of Natural Sciences, University of Tasmania, Sandy Bay, 7006, Australia; Australian Forest and Wood Innovation (AFWI), Centre for Sustainable Resource and Product Solutions, University of Tasmania, Newnham, 7248, Australia
Auto-generated profile, based on publicly available information
Estrella Sanz Rodriguez
Australian Centre for Research on Separation Science (ACROSS), Sandy Bay, 7006, Australia; ARC Training Centre for Hyphenated Analytical Separation Technologies (HyTECH), Chemistry, School of Natural Sciences, University of Tasmania, Sandy Bay, 7006, Australia; Australian Forest and Wood Innovation (AFWI), Centre for Sustainable Resource and Product Solutions, University of Tasmania, Newnham, 7248, Australia
A new ion chromatographic method for the speciation of iodine in aquacultural seawater samples has been developed. This simple, isocratic, non-suppressed ion chromatographic method, which uses an electrolytically generated potassium hydroxide eluent with a high capacity anion exchange column (Dionex IonPac AS20, 250 × 4 mm ID, 7.5 μm), allows the direct injection of undiluted seawater samples, with detection based upon standard ultraviolet absorbance (226 nm). Using a sample injection volume of 125 μL, a method limit of detection for iodide of 9.45 nM in seawater was achieved, with an absolute detection limit of 0.15 ng. Speciation (iodide/iodate) was accomplished via off-line sample reduction using ascorbic acid (0.2 M) and HCl (6 M). The new method was applied to the study of iodine speciation in raw, ultraviolet- and ozone-treated aquacultural seawater samples.
This study presents the first record of trifluoroacetic acid (TFA) in Antarctic ice cores, offering valuable data on TFA and its precursors' long-range atmospheric transport and deposition in remote polar regions. TFA is an ultra-short chain perfluoroalkyl acid (PFAA) that has gained attention due to its environmental persistence, stability, and mobility. It is primarily formed as an end product of atmospheric degradation of halogenated refrigerants and blowing agents, particularly hydrofluorocarbons (HFCs) and unsaturated HFCs (u-HFCs). In this study, a new non-suppressed ion chromatography-tandem mass spectrometry (nsIC-MS/MS) method was developed for TFA determination in samples from a 12.9 m Antarctic ice core. Using direct injection of 20 μL of ice core sample, TFA was retained on a HALO Penta-HILIC column (150 mm × 1.5 mm, 2.7 μm). Analysis was completed within 5 min at 25 °C using an isocratic mobile phase (60:40 acetonitrile:water, 1 mM ammonium formate) at 90 μL/min. Detection was performed in negative ESI-SRM mode (m/z 113 → 69), achieving a limit of detection of 0.3 ng/L. Repeatability (intra- and inter-day) was better than 7 %. A total of 260 samples were analysed from a high-resolution ice core spanning 2011-2021 CE. On average, TFA concentrations increased by 5.8 % per year over the studied period. Comparison with seasonal proxies from the same core, i.e., methanesulfonic acid (MSA), revealed TFA peaks in September-November suggesting that polar vortex weakening releases both pre-formed TFA and additional TFA from the breakdown of more stable precursors.
In this study, a compact capillary liquid chromatography (capLC) system (<10 Kg) has been coupled with two small-footprint and portable single quadrupole mass spectrometers (<35 Kg) for the analysis of haloacetic acids (HAAs) in water samples. The portable capillary liquid chromatograph was equipped with a polar-modified C18 column (100 × 0.5 mm, particle size: 3 μm) and utilised gradient elution with 0.05 % formic acid and methanol to selectively separate and quantify the 9 HAAs (HAA9) recommended for monitoring by United States Environmental Protection Agency (USEPA). The successful quantification of HAA9 was accomplished using a portable capLC-ESI-MS system with a single quadrupole mass analyser for the first time without the addition of ion-pairing agents. Direct injection was applied to analyse HAA9 in tap and swimming pool water using the system incorporating the Shimadzu LCMS-2050 mass spectrometer. The limits of the detection (LODs) attained using the capLC-MS system were below the maximum contamination level (MCL), 60 µg/L, set by USEPA for the five most common HAAs in drinking water (HAA5). Dichloroacetic acid (DCAA) was detected in local tap water at the level of 5.3 µg/L, while 142.4 µg/L and 311.4 µg/L of DCAA and trichloroacetic acid (TCAA), respectively, were determined in local swimming pool water. The small-footprint capLC-MS system is compatible with the on-site analysis within water treatment plants and provides a cost-effective and green solution for the quantification of HAA9.